Multidimensional gas chromatography using microfluidic switching and low thermal mass gas chromatography for the characterization of targeted volatile organic compounds

被引:12
作者
Luong, J. [1 ,2 ]
Gras, R. [2 ]
Hawryluk, M. [2 ]
Shellie, R. A. [1 ]
Cortes, H. J. [1 ,3 ]
机构
[1] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
[2] Dow Chem Canada ULC, Ft Saskatchewan, AB T8L 2P4, Canada
[3] HJ Cortes Consulting LLC, Midland, MI 48642 USA
基金
澳大利亚研究理事会;
关键词
Microfluidics; Low thermal mass GC; Multidimensional gas chromatography; Volatile organic compounds; CATALYTIC CRACKING; LIGHT-HYDROCARBONS; INSTRUMENTATION; BENZENE; RISK;
D O I
10.1016/j.chroma.2013.02.084
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Volatile organic compounds such as light hydrocarbons, dienes, and aromatic compounds are often encountered in the manufacturing and processing environments of chemical and petrochemical segments. These compounds need to be closely monitored for process optimization, plant maintenance and industrial hygiene purposes. A high throughput analytical approach has been successfully developed and implemented for the accurate measurement of fourteen commonly encountered analytes. The approach incorporates a recently introduced 5-port planar microfluidic device configured for use as a Deans switch for multidimensional gas chromatography. The use of multidimensional gas chromatography allows the elimination of potential chromatographic contaminants with a substantial enhancement of stationary phase selectivity via the use of columns with different separation mechanisms, and the back-flushing of heavier undesired hydrocarbons. A low thermal mass gas chromatographic module was employed in the second dimension of the two-dimensional gas chromatography system and was used to provide independent temperature control, and rapid heating and cooling to meet the high throughput requirements. By successfully combining these concepts, complete analysis of fourteen targeted components can be conducted in less than 120s. Repeatability of retention times for all compounds was found to be less than 0.05% (n = 20). Repeatability of area counts at two levels, namely 10 ppm(v) and 1000 ppm(v) over a period of two days was found to be less than 3% (n =20). Apart from methane, which has a detection limit of 0.4 ppm(v), the rest of the compounds were found to have detection limits of less than 0.2 ppm(v). Compounds of interest were found to be linear over a range of 500 ppb(v)-3000 ppm(v) with correlation coefficients greater than 0.999. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 38 条
[1]  
[Anonymous], 2010, ASTMD449210
[2]   Low cost, robust, in-house hardware for heart cutting two-dimensional gas chromatography [J].
Apps, Peter .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (15) :2338-2349
[3]  
Armstrong D.W., 1996, CURR SEP, V15, P1
[5]   The kinetic model of thermal cracking for olefins production [J].
Belohlav, Z ;
Zamostny, P ;
Herink, T .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2003, 42 (06) :461-473
[6]  
Berezkin V.G., 1996, Capillary gas adsorption chromatography
[7]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[8]  
2-V
[9]  
Bertsch W, 2000, HRC-J HIGH RES CHROM, V23, P167
[10]  
BROWN RH, 1988, IARC SCI PUBL, V85, P235