Measurement of Common Carotid Artery Lumen Dynamics during the Cardiac Cycle Using Magnetic Resonance TrueFISP Cine Imaging

被引:10
作者
Chow, Tracy Y. [1 ]
Cheung, Jerry S. [1 ]
Wu, Yin [1 ]
Guo, Hua [1 ]
Chan, Kevin C. [1 ]
Hui, Edward S. [1 ]
Wu, Ed X. [1 ]
机构
[1] Univ Hong Kong, Dept Elect & Elect Engn, Lab Biomed Imaging & Signal Proc, Pokfulam, Hong Kong, Peoples R China
关键词
arterial dynamics; TrueFISP cine imaging; common carotid artery; MRI;
D O I
10.1002/jmri.21527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate magnetic resonance (MR) measurements of vascular lumen dynamics in common carotid arteries by using true fast imaging with steady-state precession (TrueFISP) cine imaging with an aim to provide additional physiologic information on the vessels. Materials and Methods:The left and right common carotid arteries were studied in normal young men (N = 6: age = 21-24 years; body weight = 130-175 lbs) using electrocardiogram (ECG)-triggered TrueFISP cine imaging at 20 frames per cardiac cycle. Lumen area waveforms were characterized with specific time and amplitude ratios. Distension values were quantified. Results: Distension values were measured at 25.92 +/- 2.58% and 27.58 +/- 4.44% for the left and right common carotid arteries, respectively. These findings are consistent with those previously documented using ultrasound imaging in a similar age group. Consistent lumen area waveform characteristics were found among the subjects studied. Conclusion: These findings demonstrate for the first time that the use of TrueFISP cine imaging is a robust, rapid technique for quantifying carotid lumen area dynamics and distension, which may be valuable in characterizing and diagnosing cardiovascular diseases.
引用
收藏
页码:1527 / 1532
页数:6
相关论文
共 20 条
[1]   Flow compensation in balanced SSFP sequences [J].
Bieri, O ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :901-907
[2]   Effect of vasoactive drugs on carotid diameter in humans [J].
Bonyhay, I ;
Jokkel, G ;
Karlocai, K ;
Reneman, R ;
Kollai, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 273 (04) :H1629-H1636
[3]   3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing [J].
Crowe, LA ;
Keegan, J ;
Gatehouse, PD ;
Mohiaddin, RH ;
Varghese, A ;
Symmonds, K ;
Cannell, TM ;
Yang, GZ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (04) :583-588
[4]   Comparison between three-dimensional volume-selective turbo spin-echo Imaging and two-dimensional ultrasound for assessing carotid artery structure and function [J].
Crowe, LA ;
Ariff, B ;
Keegan, J ;
Mohiaddin, RH ;
Yang, GZ ;
Hughes, AD ;
Thom, SAM ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) :282-289
[5]   Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement [J].
Crowe, LA ;
Gatehouse, P ;
Yang, GZ ;
Mohiaddin, RH ;
Varghese, A ;
Charrier, C ;
Keegan, J ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :572-580
[6]  
Fayad ZA, 2000, ANN NY ACAD SCI, V902, P173
[7]   TrueFISP - technical considerations and cardiovascular applications [J].
Fuchs, F ;
Laub, G ;
Othomo, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (01) :28-32
[8]   ESTIMATION OF ARTERIAL STIFFNESS, COMPLIANCE, AND DISTENSIBILITY FROM M-MODE ULTRASOUND MEASUREMENTS OF THE COMMON CAROTID-ARTERY [J].
GAMBLE, G ;
ZORN, J ;
SANDERS, G ;
MACMAHON, S ;
SHARPE, N .
STROKE, 1994, 25 (01) :11-16
[9]   Carotid artery distensibility - A reliability study [J].
Godia, Elisa Cuadrado ;
Madhok, Rishi ;
Pittman, John ;
Trocio, Samuel ;
Ramas, Romel ;
Cabral, Digna ;
Sacco, Ralph L. ;
Rundek, Tatjana .
JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (09) :1157-1165
[10]   Age-related changes in carotid artery flow and pressure pulses - Possible implications for cerebral microvascular disease [J].
Hirata, Kozo ;
Yaginuma, Toshio ;
O'Rourke, Michael F. ;
Kawakami, Masanobu .
STROKE, 2006, 37 (10) :2552-2556