Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance

被引:123
作者
Habara, Maoto [1 ]
Nasu, Kenya [1 ]
Terashima, Mitsuyasu [1 ]
Kaneda, Hideaki [2 ]
Yokota, Daisuke [1 ]
Ko, Euihong [1 ]
Ito, Tsuyoshi [1 ]
Kurita, Tairo [1 ]
Tanaka, Nobuyoshi [1 ]
Kimura, Masashi [1 ]
Ito, Tatsuya [1 ]
Kinoshita, Yoshihisa [1 ]
Tsuchikane, Etsuo [1 ]
Asakura, Keiko [1 ]
Asakura, Yasushi [1 ]
Katoh, Osamu [1 ]
Suzuki, Takahiko [1 ]
机构
[1] Toyohashi Heart Ctr, Dept Cardiovasc Med, Toyohashi, Aichi 4418530, Japan
[2] Okinaka Mem Inst Med Res, Tokyo, Japan
关键词
optical coherence tomography; intravascular ultrasound; optimal stenting; ELUTING STENTS; INTERVENTION; SAFETY; PLAQUE; FEASIBILITY; THROMBOSIS; EXPANSION; STENOSIS; SYSTEM;
D O I
10.1161/CIRCINTERVENTIONS.111.965111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Frequency-domain optical coherence tomography (FD-OCT) is a novel, high resolution intravascular imaging modality. Intravascular ultrasound (IVUS) is a widely used conventional imaging modality for achieving optimal stent deployment. The aim of this study was to evaluate the impact of FD-OCT guidance for coronary stent implantation compared with IVUS guidance. Methods and Results-A total of 70 patients with de novo coronary artery lesions and either unstable or stable angina pectoris were enrolled in this randomized study (optical coherence tomography [OCT] group: n=35, IVUS group: n=35). In the OCT group, stent implantation was performed under FD-OCT guidance alone and final stent expansion was evaluated by IVUS. In the IVUS group, conventional IVUS guidance was used and final stent apposition was evaluated by FD-OCT. There were no significant differences regarding the procedural, fluoroscopy time, and contrast volume. Although device and clinical success rates also were similar, the visibility of vessel border was significantly lower in the OCT group (P<0.05). Minimum and mean stent area and focal and diffuse stent expansion were smaller (6.1 +/- 2.2 mm versus 7.1 +/- 2.1 mm, 7.5 +/- 2.5 versus 8.7 +/- 2.4 mm, 64.7 +/- 13.7% versus 80.3 +/- 13.4%, 84.2 +/- 15.8% versus 98.8 +/- 16.5%, P +/- 0.05, respectively), and the frequency of significant residual reference segment stenosis at the proximal edge was higher in the OCT group (P<0.05). Incomplete apposed struts in both groups were similar (P=0.34). Conclusions-FD-OCT guidance for stent implantation was associated with smaller stent expansion and more frequent significant residual reference segment stenosis compared with conventional IVUS guidance. (Circ Cardiovasc Interv. 2012; 5:193-201.)
引用
收藏
页码:193 / 201
页数:9
相关论文
共 26 条
[11]   An Integrated TAXUS IV, V, and VI Intravascular Ultrasound Analysis of the Predictors of Edge Restenosis After Bare Metal or Paclitaxel-Eluting Stents [J].
Liu, Jian ;
Maehara, Akiko ;
Mintz, Gary S. ;
Weissman, Neil J. ;
Yu, Alan ;
Wang, Hong ;
Mandinov, Lazar ;
Popma, Jeffrey J. ;
Ellis, Stephen G. ;
Grube, Eberhard ;
Dawkins, Keith D. ;
Stone, Gregg W. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (04) :501-506
[12]   A Volumetric Intravascular Ultrasound Comparison of Early Drug-Eluting Stent Thrombosis Versus Restenosis [J].
Liu, Xuebo ;
Doi, Hiroshi ;
Maehara, Akiko ;
Mintz, Gary S. ;
Costa, Jose de Ribamar, Jr. ;
Sano, Koichi ;
Weisz, Giora ;
Dangas, George D. ;
Lansky, Alexandra J. ;
Kreps, Edward M. ;
Collins, Michael ;
Fahy, Martin ;
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Leon, Martin B. ;
Mehran, Roxana .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :428-434
[13]   Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery [J].
Moses, JW ;
Leon, MB ;
Popma, JJ ;
Fitzgerald, PJ ;
Holmes, DR ;
O'Shaughnessy, C ;
Caputo, RP ;
Kereiakes, DJ ;
Williams, DO ;
Teirstein, PS ;
Jaeger, JL ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) :1315-1323
[14]   Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis? [J].
Moussa, I ;
Moses, J ;
Di Mario, C ;
Albiero, R ;
De Gregorio, J ;
Adamian, M ;
Di Francesco, L ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (07) :1012-1017
[15]   INTRACORONARY ULTRASOUND OBSERVATIONS DURING STENT IMPLANTATION [J].
NAKAMURA, S ;
COLOMBO, A ;
GAGLIONE, A ;
ALMAGOR, Y ;
GOLDBERG, SL ;
MAIELLO, L ;
FINCI, L ;
TOBIS, JM .
CIRCULATION, 1994, 89 (05) :2026-2034
[16]   Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses - Final results of a randomized comparison with angiographic guidance (TULIP study) [J].
Oemrawsingh, PV ;
Mintz, GS ;
Schalij, MJ ;
Zwinderman, AH ;
Jukema, JW ;
Van der Wall, EE .
CIRCULATION, 2003, 107 (01) :62-67
[17]   From bench to bedside - A novel technique of acquiring OCT images [J].
Prati, Francesco ;
Cera, Maria ;
Ramazzotti, Vito ;
Imola, Fabrizio ;
Giudice, Rocco ;
Giudice, Marco ;
De Propris, Silvia ;
Albertucci, Mario .
CIRCULATION JOURNAL, 2008, 72 (05) :839-843
[18]   IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled [J].
Rogacka, Renata ;
Latib, Azeem ;
Colombo, Antonio .
CURRENT CARDIOLOGY REVIEWS, 2009, 5 (02) :78-86
[19]   The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents [J].
Roy, Probal ;
Steinberg, Daniel H. ;
Sushinsky, Steven J. ;
Okabe, Teruo ;
Slottow, Tina L. Pinto ;
Kaneshige, Kimberly ;
Xue, Zhenyi ;
Satler, Lowell F. ;
Kent, Kenneth M. ;
Suddath, William O. ;
Pichard, Augusto D. ;
Weissman, Neil J. ;
Lindsay, Joseph ;
Waksman, Ron .
EUROPEAN HEART JOURNAL, 2008, 29 (15) :1851-1857
[20]   A Randomized Controlled Trial of Angiography Versus Intravascular Ultrasound-Directed Bare-Metal Coronary Stent Placement (The AVID Trial) [J].
Russo, Robert J. ;
Silva, Patricia D. ;
Teirstein, Paul S. ;
Attubato, Michael J. ;
Davidson, Charles J. ;
DeFranco, Anthony C. ;
Fitzgerald, Peter J. ;
Goldberg, Steven L. ;
Hermiller, James B. ;
Leon, Martin B. ;
Ling, Frederick S. ;
Lucisano, Jennifer E. ;
Schatz, Richard A. ;
Wong, S. Chiu ;
Weissman, Neil J. ;
Zientek, David M. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (02) :113-U56