Infrared vision using uncooled micro-optomechanical camera

被引:104
作者
Perazzo, T
Mao, M
Kwon, O
Majumdar, A [1 ]
Varesi, JB
Norton, P
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[2] Santa Barbara Res Ctr, Goleta, CA 93117 USA
关键词
D O I
10.1063/1.124163
中图分类号
O59 [应用物理学];
学科分类号
摘要
This letter presents the design, fabrication, and imaging results of an uncooled infrared (IR) camera that contains a focal plane array of bimaterial microcantilever sensors, and an optical readout technique that measures cantilever deflections in the nanometer range to directly project a visible image of the IR scene on the human eye or a visible camera. The results suggest that objects at temperatures as low as 100 degrees C can be imaged with the best noise-equivalent temperature difference (NE Delta T) in the range of 10 K. It is estimated that further improvements that are currently being pursued can improve NE Delta T to about 50 mK. (C) 1999 American Institute of Physics. [S0003-6951(99)00523-9].
引用
收藏
页码:3567 / 3569
页数:3
相关论文
共 11 条
[1]   PHOTOTHERMAL SPECTROSCOPY WITH FEMTOJOULE SENSITIVITY USING A MICROMECHANICAL DEVICE [J].
BARNES, JR ;
STEPHENSON, RJ ;
WELLAND, ME ;
GERBER, C ;
GIMZEWSKI, JK .
NATURE, 1994, 372 (6501) :79-81
[2]   A FEMTOJOULE CALORIMETER USING MICROMECHANICAL SENSORS [J].
BARNES, JR ;
STEPHENSON, RJ ;
WOODBURN, CN ;
OSHEA, SJ ;
WELLAND, ME ;
RAYMENT, T ;
GIMZEWSKI, JK ;
GERBER, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (12) :3793-3798
[3]  
Born M., 1986, PRINCIPLES OPTICS
[4]   OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR [J].
GIMZEWSKI, JK ;
GERBER, C ;
MEYER, E ;
SCHLITTLER, RR .
CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) :589-594
[5]   Optimization and performance of high-resolution micro-optomechanical thermal sensors [J].
Lai, J ;
Perazzo, T ;
Shi, Z ;
Majumdar, A .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 58 (02) :113-119
[6]   Interdigital cantilevers for atomic force microscopy [J].
Manalis, SR ;
Minne, SC ;
Atalar, A ;
Quate, CF .
APPLIED PHYSICS LETTERS, 1996, 69 (25) :3944-3946
[7]   Two-dimensional micromechanical bimorph arrays for detection of thermal radiation [J].
Manalis, SR ;
Minne, SC ;
Quate, CF ;
Yaralioglu, GG ;
Atalar, A .
APPLIED PHYSICS LETTERS, 1997, 70 (24) :3311-3313
[8]   Direct-view uncooled micro-optomechanical infrared camera [J].
Mao, M ;
Perazzo, T ;
Kwon, O ;
Majumdar, A ;
Varesi, J ;
Norton, P .
MEMS '99: TWELFTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 1999, :100-105
[9]   Uncooled thermal imaging using a piezoresistive microcantilever [J].
Oden, PI ;
Datskos, PG ;
Thundat, T ;
Warmack, RJ .
APPLIED PHYSICS LETTERS, 1996, 69 (21) :3277-3279
[10]  
Sarid D., 1991, SCANNING FORCE MICRO