Zigzag sampling for improved parallel imaging

被引:36
作者
Breuer, Felix A. [1 ]
Moriguchi, Hisamoto [2 ]
Seiberlich, Nicole [3 ]
Blaimer, Martin [1 ]
Jakob, Peter M. [1 ,3 ]
Duerk, Jeffrey L. [4 ,5 ]
Griswold, Mark A. [5 ]
机构
[1] Magnet Resonance Bavaria, Res Ctr, D-97074 Wurzburg, Germany
[2] Tokai Univ, Dept Radiol, Isehara, Kanagawa, Japan
[3] Univ Wurzburg, Dept Expt Phys 5, Wurzburg, Germany
[4] Case Western Reserve Univ, Cleveland, OH 44106 USA
[5] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
zigzag sampling; parallel imaging; MRI; GRAPPA; CAIPIRINHA;
D O I
10.1002/mrm.21643
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional Cartesian parallel MRI methods are limited to the sensitivity variations provided by the underlying receiver coil array in the dimension in which the data reduction is carried out, namely, the phase-encoding directions. However, in this work an acquisition strategy is presented that takes advantage of sensitivity variations in the readout direction, thus improving the parallel imaging reconstruction process. This is achieved by employing rapidly oscillating phase-encoding gradients during the actual readout. The benefit of this approach is demonstrated in vivo using various zigzag-shaped gradient trajectory designs. It is shown that zigzag type sampling, in analogy to CAIPIRINHA, modifies the appearance of aliasing in 2D and 3D imaging, thereby utilizing additional sensitivity variations in the readout direction directly resulting in improved parallel imaging reconstruction performance.
引用
收藏
页码:474 / 478
页数:5
相关论文
共 16 条
[1]   2D-GRAPPA-operator for faster 3D parallel MRI [J].
Blaimer, Martin ;
Breuer, Felix A. ;
Mueller, Matthias ;
Seiberlich, Nicole ;
Ebel, Dmitry ;
Heidemann, Robin M. ;
Griswold, Mark A. ;
Jakob, Peter M. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) :1359-1364
[2]  
BREUER F, 2006, P ESMRMB, V23
[3]   Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA) [J].
Breuer, FA ;
Blaimer, M ;
Mueller, MF ;
Seiberlich, N ;
Heidemann, RM ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :549-556
[4]   Simple correction method for k-space trajectory deviations in MRI [J].
Duyn, JH ;
Yang, YH ;
Frank, JA ;
van der Veen, JW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :150-153
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]  
Griswold MA, 2003, P INT SOC MAGN RESON, V11, P2349
[7]   Auto-calibrated parallel spiral imaging [J].
Heberlein, K ;
Hu, XP .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :619-625
[8]   Direct parallel image reconstructions for spiral trajectories using GRAPPA [J].
Heidemann, Robin M. ;
Griswold, Mark A. ;
Seiberlich, Nicole ;
Krueger, Gunnar ;
Kannengiesser, Stephan A. R. ;
Kiefer, Berthold ;
Wiggins, Graham ;
Wald, Lawrence L. ;
Jakob, Peter M. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :317-326
[9]  
Jakob P, 2006, P INT SOC MAGN RESON, P286
[10]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO