Functional MRI of the Lungs Using Single Breath-Hold and Self-Navigated Ultrashort Echo Time Sequences

被引:11
作者
Heidenreich, Julius F. [1 ]
Veldhoen, Simon [1 ]
Metz, Corona [1 ]
Pereira, Lenon Mendes [1 ]
Benkert, Thomas [2 ]
Pfeuffer, Josef [2 ]
Bley, Thorsten A. [1 ]
Kostler, Herbert [1 ]
Weng, Andreas M. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Siemens Healthcare, Dept Applicat Dev, Erlangen, Germany
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2020年 / 2卷 / 03期
关键词
D O I
10.1148/ryct.2020190162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate three-dimensional (3D) ultrashort echo time (UTE) MRI regarding image quality and suitability for functional image analysis using gradient-echo sequences in breath-hold and with self-navigation. Materials and Methods: In this prospective exploratory study, 10 patients (mean age, 21 years; age range, 558 years; five men) and 10 healthy control participants (mean age, 25 years; age range, 1039 years; five men) underwent 3D UTE MRI at 3.0 T. Imaging was performed with a prototypical stack-of-spirals 3D UTE sequence during single breath holds (echo time [TE], 0.05 msec) and with a self-navigated Koosh ball 3D UTE sequence at free breathing (TE, 0.03 msec). Image quality was rated on a four-point Likert scale. Edge sharpness was calculated. After semiautomated segmentation, fractional ventilation was calculated from MRI signal intensity (FVSI) and volume change (FVVol). The air volume fraction (AVF) was estimated from relative signal intensity (aortic blood signal intensity was used as a reference). Means were compared between techniques and participants. The Wilcoxon signed rank test and Spearman rank correlation were used for statistical analyses. Results: Image quality ratings were equal for both techniques. However, stack-of-spirals breath-hold UTE was more susceptible to motion and aliasing artifacts. Mean FVSI was higher during breath hold than at free breathing (mean +/- standard deviation in milliliters of gas per milliliters of parenchyma, 0.17 mL/mL +/- 0.06 [minimum, 0.07; maximum, 0.34] vs 0.11 mL/mL +/- 0.03 [minimum, 0.06; maximum, 0.17], P = .016). Mean FVSI and FVVol were in good agreement (mean difference: at breath hold, -0.008 [95% confidence interval {CI}: 0.007, -0.024]; rho = 0.97 vs free breathing, -0.004 [95% CI: 0.007, -0.016]; rho = 0.91). AVF correlated between both techniques (rho = 0.94). Conclusion: Breath-hold and self-navigated 3D UTE sequences yield proton densityweighted images of the lungs that are similar in quality, and both techniques are suitable for functional image analysis. Summary Three-dimensional ultrashort echo time gradient-echo sequences are promising tools for acquisition of proton density-weighted lung MR images within a single breath hold or at free breathing, providing high spatial resolution and allowing for functional image analysis such as ventilation or air volume fraction.
引用
收藏
页数:7
相关论文
共 21 条
  • [1] Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    Barger, AV
    Block, WF
    Toropov, Y
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 297 - 305
  • [2] Simultaneous MRI of Lung Structure and Perfusion in a Single Breathhold
    Bell, Laura C.
    Johnson, Kevin M.
    Fain, Sean B.
    Wentland, Andrew
    Drees, Randi
    Johnson, Rebecca A.
    Bauman, Grzegorz
    Francois, Christopher J.
    Nagle, Scott K.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (01) : 52 - 59
  • [3] Automated Volumetric Quantification of Emphysema Severity by Using Ultrashort Echo Time MRI: Validation in Participants wits Chronic Obstructive Pulmonary Disease
    Benlala, Ilyes
    Berger, Patrick
    Girodet, Pierre-Olivier
    Dromer, Claire
    Macey, Julie
    Laurent, Francois
    Dournes, Gael
    [J]. RADIOLOGY, 2019, 292 (01) : 216 - 225
  • [4] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [5] Carinci F, 2015, P 23 M INT SOC MAGNE, P3975
  • [6] In vivo imaging of the spectral line broadening of the human lung in a single breathhold
    Carinci, Flavio
    Meyer, Cord
    Breuer, Felix A.
    Jakob, Peter M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) : 745 - 757
  • [7] Simultaneous Evaluation of Lung Anatomy and Ventilation Using 4D Respiratory-Motion-Resolved Ultrashort Echo Time Sparse MRI
    Feng, Li
    Delacoste, Jean
    Smith, David
    Weissbrot, Joseph
    Flagg, Eric
    Moore, William H.
    Girvin, Francis
    Raad, Roy
    Bhattacharji, Priya
    Stoffel, David
    Piccini, Davide
    Stuber, Matthias
    Sodickson, Daniel K.
    Otazo, Ricardo
    Chandarana, Hersh
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (02) : 411 - 422
  • [8] SElf-gated Non-Contrast-Enhanced FUnctional Lung imaging (SENCEFUL) using a quasi-random fast low-angle shot (FLASH) sequence and proton MRI
    Fischer, Andre
    Weick, Stefan
    Ritter, Christian O.
    Beer, Meinrad
    Wirth, Clemens
    Hebestreit, Helge
    Jakob, Peter M.
    Hahn, Dietbert
    Bley, Thorsten
    Koestler, Herbert
    [J]. NMR IN BIOMEDICINE, 2014, 27 (08) : 907 - 917
  • [9] Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)
    Grodzki, David M.
    Jakob, Peter M.
    Heismann, Bjoern
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 510 - 518
  • [10] Quantification of Neonatal Lung Parenchymal Density via Ultrashort Echo Time MRI With Comparison to CT
    Higano, Nara S.
    Fleck, Robert J.
    Spielberg, David R.
    Walkup, Laura L.
    Hahn, Andrew D.
    Thomen, Robert P.
    Merhar, Stephanie L.
    Kingma, Paul S.
    Tkach, Jean A.
    Fain, Sean B.
    Woods, Jason C.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (04) : 992 - 1000