Interactive MR-guided percutaneous nephrostomy

被引:17
作者
Hagspiel, KD [1 ]
Kandarpa, K [1 ]
Silverman, SG [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol,Div Cardiovasc & Intervent Radiol, Boston, MA 02115 USA
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 06期
关键词
interventional procedures; technology; magnetic resonance; guidance; percutaneous nephrostomy;
D O I
10.1002/jmri.1880080619
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Open-configuration MRI systems have been recently introduced and hold promise to allow the performance of a variety of minimally invasive procedures. Experience with MR-guided catheter-based luminal interventions is experimental to date, This is the first case of a successful percutaneous nephrostomy tube placement in a patient in an interventional MR system. The procedure was performed completely under MR guidance, and technical aspects are reviewed and compared with other, established techniques for percutaneous nephrostomy placement.
引用
收藏
页码:1319 / 1322
页数:4
相关论文
共 12 条
[1]  
CASTANEDAZUNIGA WR, 1997, INT RADIOLOGY, V2, P1049
[2]  
Gupta S, 1997, ACTA RADIOL, V38, P454
[3]  
KANAL E, 1991, JMRI-J MAGN RESON IM, V2, P97
[4]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270
[5]   SUPERCONDUCTING OPEN-CONFIGURATION MR-IMAGING SYSTEM FOR IMAGE-GUIDED THERAPY [J].
SCHENCK, JF ;
JOLESZ, FA ;
ROEMER, PB ;
CLINE, HE ;
LORENSEN, WE ;
KIKINIS, R ;
SILVERMAN, SG ;
HARDY, CJ ;
BARBER, WD ;
LASKARIS, ET ;
DORRI, B ;
NEWMAN, RW ;
HOLLEY, CE ;
COLLICK, BD ;
DIETZ, DP ;
MACK, DC ;
AINSLIE, MD ;
JASKOLSKI, PL ;
FIGUEIRA, MR ;
LEHN, JCV ;
SOUZA, SP ;
DUMOULIN, CL ;
DARROW, RD ;
STPETERS, RL ;
ROHLING, KW ;
WATKINS, RD ;
EISNER, DR ;
BLUMENFELD, SM ;
VOSBURGH, KG .
RADIOLOGY, 1995, 195 (03) :805-814
[6]   Design and implementation of an interventional MR imaging suite [J].
Silverman, SG ;
Jolesz, FA ;
Newman, RW ;
Morrison, PR ;
Kanan, AR ;
Kikinis, R ;
Schwartz, RB ;
Hsu, LG ;
Koran, SJ ;
Topulos, GP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1465-1471
[7]   INTERACTIVE MR-GUIDED BIOPSY IN AN OPEN-CONFIGURATION MR-IMAGING SYSTEM [J].
SILVERMAN, SG ;
COLLICK, BD ;
FIGUEIRA, MR ;
KHORASANI, R ;
ADAMS, DF ;
NEWMAN, RW ;
TOPULOS, GP ;
JOLESZ, FA .
RADIOLOGY, 1995, 197 (01) :175-181
[8]   A WIRE-SHEATH SYSTEM FOR MR-GUIDED BIOPSY AND DRAINAGE - LABORATORY STUDIES AND EXPERIENCE IN 10 PATIENTS [J].
VANSONNENBERG, E ;
HAJEK, P ;
GYLYSMORIN, V ;
VARNEY, RA ;
BAKER, L ;
CASOLA, G ;
CHRISTENSEN, R ;
MATTREY, RF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) :815-817
[9]  
VANSONNENBERG E, 1994, AJR, V158, P91
[10]   MALIGNANT LIVER-TUMORS TREATED WITH MR IMAGING-GUIDED LASER-INDUCED THERMOTHERAPY - TECHNIQUE AND PROSPECTIVE RESULTS [J].
VOGL, TJ ;
MULLER, PK ;
HAMMERSTINGL, R ;
WEINHOLD, N ;
MACK, MG ;
PHILIPP, C ;
DEIMLING, M ;
BEUTHAN, J ;
PEGIOS, W ;
RIESS, H ;
LEMMENS, HP ;
FELIX, R .
RADIOLOGY, 1995, 196 (01) :257-265