Characterization of One-Dimensional Fiber-Optic Scintillating Detectors for Electron-Beam Therapy Dosimetry

被引:12
作者
Lee, Bongsoo [1 ]
Jang, Kyoung Won [1 ]
Cho, Dong Hyun [1 ]
Yoo, Wook Jae [1 ]
Shin, Sang Hun [1 ]
Tack, Gye-Rae [1 ]
Chung, Soon-Cheol [1 ]
Kim, Sin [2 ]
Cho, Hyosung [3 ,4 ]
Park, Byung Gi [5 ]
Moon, Joo Hyun [6 ]
Kim, Siyong [7 ]
机构
[1] Konkuk Univ, Res Inst Biomed Engn, Sch Biomed Engn, Chungju 380701, South Korea
[2] Jeju Natl Univ, Appl Radiol Sci Res Inst, Dept Nucl & Energy Engn, Cheju 690756, South Korea
[3] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
[4] Yonsei Univ, Basic Atom Energy Res Inst, Wonju 220710, South Korea
[5] Soonchunhyang Univ, Dept Energy & Environm Engn, Asan 336745, South Korea
[6] Dongguk Univ, Dept Energy & Environm Syst Engn, Gyeongju 780714, South Korea
[7] Mayo Clin, Dept Radiat Oncol, Jacksonville, FL 32224 USA
关键词
Cerenkov light; electron beam; fiber-optic detector; organic scintillator; plastic optical fiber;
D O I
10.1109/TNS.2008.2002578
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, a one-dimensional fiber-optic scintillating detector was developed for electron-beam therapy dosimetry. Each fiber-optic detector contains an organic scintillator as a sensitive volume and it is embedded and arrayed in a plastic phantom to measure one-dimensional high-energy electron-beam profiles of clinical linear accelerators. Plastic optical fibers guide the scintillating light which each detector probe generates to a photodiode array. The one-dimensional electron-beam profiles in the plastic phantom were measured in two different field sizes and for two electron-beam energies. Also, isodose and two-dimensional dose distributions in the plastic phantom were obtained using the one-dimensional scintillating detector array with two different electron beam energies.
引用
收藏
页码:2627 / 2631
页数:5
相关论文
共 9 条
[1]   Plastic scintillation dosimetry and its application to radiotherapy [J].
Beddar, A. S. .
RADIATION MEASUREMENTS, 2006, 41 :S124-S133
[2]   Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams [J].
Clift, MA ;
Sutton, RA ;
Webb, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1165-1182
[3]   Spectral discrimination of Cerenkov radiation in scintillating dosimeters [J].
Frelin, AM ;
Fontbonne, JM ;
Ban, G ;
Colin, J ;
Labalme, M ;
Batalla, A ;
Isambert, A ;
Vela, A ;
Leroux, T .
MEDICAL PHYSICS, 2005, 32 (09) :3000-3006
[4]  
*HAM PHOT CO, 2006, SEL GUID SI PHOT, P32
[5]  
HENDEE WR, 2005, RAD THERAPY, P151
[6]  
KHAN FM, 1994, PHYS RAD THERAPY, P179
[7]   Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry [J].
Lee, Bongsoo ;
Jang, Kyoung Won ;
Cho, Dong Hyun ;
Yoo, Wook Jae ;
Tack, Gye-Rac ;
Chung, Soon-Cheol ;
Kim, Sin ;
Choc, Hyosung .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01) :344-348
[8]   Measurements and characterization of Cerenkov light in fiber-optic radiation sensor irradiated by high-energy electron beam [J].
Lee, Bongsoo ;
Cho, Dong Hyun ;
Jang, Kyoung Won ;
Chung, SOon-Cheol ;
Lee, Jeong-Whan ;
Kim, Sin ;
Cho, Hyosung .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (10A) :7980-7982