Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study

被引:71
作者
Apivatthakakul, T. [1 ]
Phaliphot, J. [1 ]
Leuvitoonvechkit, S. [1 ]
机构
[1] Chiang Mai Univ, Dept Orthoped, Fac Med, Chiang Mai 50000, Thailand
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2013年 / 44卷 / 02期
关键词
Percutaneous cerclage wiring; Femoral blood supply; Superficial femoral artery; Deep femoral artery; Perforating arteries; INVASIVE PLATE OSTEOSYNTHESIS; INTERNAL-FIXATION; FRACTURE; EVOLUTION; ANATOMY; INJURY; CABLES; ARTERY;
D O I
10.1016/j.injury.2012.10.016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: A percutaneous cerclage wiring technique has been developed to reduce iatrogenic soft tissue and vascular disruption associated with classic cerclage fixation. Objectives: The purpose of this study was to evaluate the extent of femoral vascular disruption resulting iatrogenically from the application of two percutaneous cerclage wire loops. Methods: Pairs of cerlage wire loops were percutaneously inserted on 18 fresh cadaveric femurs. The position of the wire loops varied. The wire loops were either inserted 10 and 15 cm, 10 and 20 cm, or 15 and 20 cm distal to the tip of the greater trochanter. Each study group had 6 cadavers. Contralateral femurs without cerclage wiring were used as controls. Liquid contrast-gelatin was injected into the common femoral artery. Using axial and 3D CT scan images the superficial femoral artery (SFA), deep femoral artery (DFA), perforating arteries and their anastomotic patterns as well as endosteal perfusion were identified and their patency was graded. Results: Percutaneous cerclage wiring did not disrupt femoral endosteal blood supply and maintained the integrity of all of the superficial femoral arteries. Four specimens demonstrated maintenance of all 4 perforators, 11 showed disruption of 1 perforator, and 3 showed disruption of 2 perforators. One deep femoral artery was disrupted after its first perforator branched off; however, perfusion was maintained by fill from an alternative anastamosis. There was no significant difference between disruption of deep femoral arteries and perforating arteries (P = 1.000), location of wiring (P = 0.905) or spacing between wire loops (P = 1.000). Conclusion: Percutaneous cerclage wiring resulted in minimal disruption of the femoral blood supply. When partial disruption occurred the SFA, DFA, and their associated perforators compensated to maintain femoral perfusion through their anastomoses. The location of the cerclage wire and the distance between the wire loops in the proximal femur showed no significant difference in the rate of iatrogenic perforator injury. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 22 条
[1]   Case report - Superficial femoral artery injury resulting from cerclage wiring during revision THA [J].
Aleto, Thomas ;
Ritter, Merrill A. ;
Berend, Michael E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (03) :749-753
[2]   Percutaneous cerclage wiring for reduction of periprosthetic and difficult femoral fractures. A technical note [J].
Apivatthakakul, T. ;
Phornphutkul, C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06) :966-971
[3]   Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated [J].
Apivatthakakul, T. ;
Chiewcharntanakit, S. .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) :1119-1126
[4]   Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures [J].
Apivatthakakul, Theerachai ;
Phornphutkul, C. ;
Bunmaprasert, T. ;
Sananpanich, K. ;
Fernandez Dell'Oca, Alberto .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (06) :813-822
[5]   Cerclage wires or cables for the management of Intraoperative fracture associated with a cementless, tapered femoral prosthesis [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Chonko, DJ ;
Dodds, KL ;
Adams, JB .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :17-21
[6]  
Brookes M, 1971, BLOOD SUPPLY BONE AP
[7]  
COLBORN GL, 1995, AM SURGEON, V61, P336
[8]  
Farouk O, 1997, INJURY, V28, pSA7
[9]   Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? [J].
Farouk, O ;
Krettek, C ;
Miclau, T ;
Schandelmaier, P ;
Guy, P ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) :401-406
[10]  
Farouk O, 1999, CLIN ORTHOP RELAT R, P255