Feasibility and Potential Assessment of BCHP systems for Commercial Buildings in Shanghai

被引:0
作者
Wu, Qiong [1 ]
Ren, Hongbo [1 ]
Zhou, Jian [2 ]
Liu, Shu [2 ]
Yang, Xiu [3 ]
机构
[1] Shanghai Univ Elect Power, Coll Energy & Mech Engn, Shanghai 200090, Peoples R China
[2] SMEPC, State Grid Elect Power Res Inst, Shanghai 200122, Peoples R China
[3] Shanghai Univ Elect Power, Coll Elect Engn, Shanghai 200090, Peoples R China
来源
CLEAN ENERGY FOR CLEAN CITY: CUE 2016 - APPLIED ENERGY SYMPOSIUM AND FORUM: LOW-CARBON CITIES AND URBAN ENERGY SYSTEMS | 2016年 / 104卷
基金
中国国家自然科学基金;
关键词
BCHP; technical feasibility; commercial building; energy performance; Shanghai; POWER-SYSTEM; OPTIMIZATION; DESIGN; ENERGY; CHINA; HEAT;
D O I
10.1016/j.egypro.2016.12.043
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, while considering the relationship between BCHP (Building Cooling Heating & Power) system and macro gird as well as its running strategies, three scenarios have been assumed for the assessment of the technical potential of BCHP systems for commercial buildings located in Shanghai, China. According to the simulation results, for the scenario without power export, the office building has the largest potential, followed by hotel and sports building; otherwise, office, store and hotel enjoy larger potential than other types of buildings. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:251 / 256
页数:6
相关论文
共 9 条
[1]   A detailed MILP optimization model for combined cooling, heat and power system operation planning [J].
Bischi, Aldo ;
Taccari, Leonardo ;
Martelli, Emanuele ;
Amaldi, Edoardo ;
Manzolini, Giampaolo ;
Silva, Paolo ;
Campanari, Stefano ;
Macchi, Ennio .
ENERGY, 2014, 74 :12-26
[2]   Simulation and optimization of the performance in the air-conditioning season of a BCHP system in China [J].
Cao, Jia-cong ;
Liu, Feng-qiang .
ENERGY AND BUILDINGS, 2008, 40 (03) :185-192
[3]   Optimization of CHCP (combined heat power and cooling) systems operation strategy using dynamic programming [J].
Facci, Andrea Luigi ;
Andreassi, Luca ;
Ubertini, Stefano .
ENERGY, 2014, 66 :387-400
[4]   Integrated assessment of combined cooling heating and power systems under different design and management options for residential buildings in Shanghai [J].
Gu, Qunyin ;
Ren, Hongbo ;
Gao, Weijun ;
Ren, Jianxing .
ENERGY AND BUILDINGS, 2012, 51 :143-152
[5]   Role of BCHP in energy and environmental sustainable development and its prospects in China [J].
Hao, Xiaoli ;
Zhang, Guoqiang ;
Chen, Youming .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (08) :1827-1842
[6]   Feasibility assessment of introducing distributed energy resources in urban areas of China [J].
Ren, Hongbo ;
Zhou, Weisheng ;
Nakagami, Ken'ichi ;
Gao, Weijun ;
Wu, Qiong .
APPLIED THERMAL ENGINEERING, 2010, 30 (16) :2584-2593
[7]   Reliability and availability analysis of redundant BCHP (building cooling, heating and power) system [J].
Wang, Jiang-Jiang ;
Fu, Chao ;
Yang, Kun ;
Zhang, Xu-Tao ;
Shi, Guo-hua ;
Zhai, John .
ENERGY, 2013, 61 :531-540
[8]   Influence analysis of building types and climate zones on energetic, economic and environmental performances of BCHP systems [J].
Wang, Jiangjiang ;
Zhai, Zhiqiang ;
Jing, Youyin ;
Zhang, Chunfa .
APPLIED ENERGY, 2011, 88 (09) :3097-3112
[9]   Optimization design of BCHP system to maximize to save energy and reduce environmental impact [J].
Wang, Jiangjiang ;
Zhai, Zhiqiang ;
Jing, Youyin ;
Zhang, Chunfa .
ENERGY, 2010, 35 (08) :3388-3398