Determination of Glucocorticoids using Cosurfactants Ultrasonic-Thermostatic-Assisted Cloud Point Extraction Followed by High Performance Liquid Chromatography

被引:4
作者
Qin, Hui [1 ]
Li, Gao Feng [2 ]
Chen, Nan [2 ]
Yang, Ya Ling [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Peoples R China
[2] Tumor Hosp Yunnan Prov, Kunming 650106, Peoples R China
关键词
CUS-CPE; glucocorticoids; DC-193; human urine; HPLC-UV; HUMAN PLASMA; HPLC METHOD; DEXAMETHASONE; PREDNISOLONE; SOLVENT;
D O I
10.1590/S0103-50532012005000080
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel approach, cosurfactants ultrasonic-thermostatic-assisted cloud point extraction (CUS-CPE) combined with high performance liquid chromatography and ultraviolet detection (HPLC-UV) is developed for the analysis of glucocorticoids (beclometasone dipropionate (BD), hydrocortisone butyrate (HB) and nandrolone phenylpropionate (NPP)) in human urine samples. In this study, four different cloud point extraction (CPE) systems are discussed, including DC-193-nonanoic acid, DC-193-sodium sulfate, DC-193-lauric acid and the classic Triton X-100 sulfate systems. Among them, DC-193-sodium sulfate and the classic Triton X-100 sulfate systems has been studied in the past few years. Comparing with the first two systems, DC-193-nonanoic acid system had a lower cloud point (CP), little UV absorbance and it is less damaging to the column of three glucocorticoids in same surfactant concentration which was required for application as a pre-concentration process prior to HPLC. Phase diagrams were used to study the cavitation and mass transfer behaviors of the two phases on micelles of polyether type organic silicon surfactant, PEG-12 dimethicone (DC-193). The volumes of surfactant-rich phase obtained were very small (the enrichment factor (EF) was 35), which was much smaller and had a quick phase separating speed than that of Triton X-100 in the same surfactant concentration. Linearity was investigated from 1 to 350 ng mL(-1). The limits of detection (LOD) thus estimated were 1.29 for BD, 2.67 for HB and 3.33 ng mL(-1) for NPP, respectively. In proposed CPE step is rapid and effective to obtain recovery of three glucocorticoids higher than 85%, which is similar or better than literature reported data. The method was shown to be selective, linear, precise and reproducible and successfully applied for the analysis of glucocorticoids in human urine samples.
引用
收藏
页码:2075 / 2083
页数:9
相关论文
共 26 条
[1]   Optimization of cloud point extraction and solid phase extraction methods for speciation of arsenic in natural water using multivariate technique [J].
Baig, Jameel A. ;
Kazi, Tasneem G. ;
Shah, Abdul Q. ;
Arain, Mohammad B. ;
Afridi, Hassan I. ;
Kandhro, Ghulam A. ;
Khan, Sumaira .
ANALYTICA CHIMICA ACTA, 2009, 651 (01) :57-63
[2]  
Balaji K, 2008, AFR J PHARM PHARMACO, V2, P157
[3]   Estimating provisional acceptable residues for extralabel drug use in livestock [J].
Baynes, RE ;
Martin-Jiménez, T ;
Craigmill, AL ;
Riviere, JE .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 1999, 29 (03) :287-299
[4]   Nanomolar and Selective Determination of Epinephrine in the Presence of Norepinephrine Using Carbon Paste Electrode Modified with Carbon Nanotubes and Novel 2-(4-Oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl-hydrazinecarbothioamide [J].
Beitollahi, Hadi ;
Karimi-Maleh, Hassan ;
Khabazzadeh, Hojatollah .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9848-9851
[5]   A validated, stability-indicating HPLC method for the determination of dexamethasone related substances on dexamethasone-coated drug-eluting stents [J].
Chen, Quan ;
Zielinsk, Dorota ;
Chen, Jenny ;
Koski, Andrew ;
Werst, David ;
Nowak, Steve .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) :732-738
[6]   Determination of dexamethasone and two excipients (creatinine and propylparaben) in injections by using UV-spectroscopy and multivariate calibrations [J].
Collado, MS ;
Robles, JC ;
De Zan, M ;
Cámara, MS ;
Mantovani, VE ;
Goicoechea, HC .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2001, 229 (1-2) :205-211
[7]   Immunocytochemical study of the glucocorticoid receptor in rat liver nuclei after hyperthermic stress [J].
Cvoro, A ;
Korac, A ;
Matic, G .
CELL BIOLOGY INTERNATIONAL, 2003, 27 (05) :403-407
[8]  
De Wasch K, 1998, ANALYST, V123, P2415, DOI 10.1039/a804932g
[9]  
Hamid R. Z., 2010, SENSOR ACTUAT B-CHEM, V143, P666
[10]   Novel polyethylene glycol induced cloud point system for extraction and back-extraction of organic compounds [J].
Liang, Rui ;
Wang, Zhilong ;
Xu, Jian-He ;
Li, Wei ;
Qi, Hanshi .
SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 66 (02) :248-256