Simulating indoor concentrations of NO2 and PM2.5 in multifamily housing for use in health-based intervention modeling

被引:64
作者
Fabian, P. [1 ,2 ]
Adamkiewicz, G. [2 ]
Levy, J. I. [1 ,2 ]
机构
[1] Boston Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02215 USA
[2] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
关键词
NO2; PM2; 5; Indoor air; Modeling; CONTAM; Public housing; INNER-CITY CHILDREN; PARTICULATE MATTER; NITROGEN-DIOXIDE; PERSONAL EXPOSURE; LUNG-FUNCTION; ASTHMATIC-CHILDREN; TOBACCO-SMOKE; AIR-POLLUTION; PARTICLES; SCHOOLCHILDREN;
D O I
10.1111/j.1600-0668.2011.00742.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Residents of low-income multifamily housing can have elevated exposures to multiple environmental pollutants known to influence asthma. Simulation models can characterize the health implications of changing indoor concentrations, but quantifying the influence of interventions on concentrations is challenging given complex airflow and source characteristics. In this study, we simulated concentrations in a prototype multifamily building using CONTAM, a multizone airflow and contaminant transport program. Contaminants modeled included PM(2.5) and NO(2), and parameters included stove use, presence and operability of exhaust fans, smoking, unit level, and building leakiness. We developed regression models to explain variability in CONTAM outputs for individual sources, in a manner that could be utilized in simulation modeling of health outcomes. To evaluate our models, we generated a database of 1000 simulated households with characteristics consistent with Boston public housing developments and residents and compared the predicted levels of NO(2) and PM(2.5) and their correlates with the literature. Our analyses demonstrated that CONTAM outputs could be readily explained by available parameters (R(2) between 0.89 and 0.98 across models), but that one-compartment box models would mischaracterize concentrations and source contributions. Our study quantifies the key drivers for indoor concentrations in multifamily housing and helps to identify opportunities for interventions.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 47 条
[1]  
[Anonymous], 2000, Simulation modeling and analysis
[2]  
[Anonymous], 2000, Clearing the air: asthma and indoor air exposures
[3]  
*ASHRAE INC, 2005, ASHRAE HDB FUND
[4]   Predictors of concentrations of nitrogen dioxide, ne particulate matter, and particle constituents inside of lower socioeconomic status urban homes [J].
Baxter, Lisa K. ;
Clougherty, Jane E. ;
Laden, Francine ;
Levy, Jonathan I. .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2007, 17 (05) :433-444
[5]   Comparison of multiple environmental factors for asthmatic children in public housing [J].
Brugge, D ;
Vallarino, J ;
Ascolillo, L ;
Osgood, ND ;
Steinbach, S ;
Spengler, J .
INDOOR AIR, 2003, 13 (01) :18-27
[6]  
Brugge D, 2001, New Solut, V11, P149
[7]  
Brunekreef B., 2005, PERSONAL INDOOR OUTD, V127, P1
[8]   A population exposure model for particulate matter:: case study results for PM2.5 in Philadelphia, PA [J].
Burke, JM ;
Zufall, MJ ;
Özkaynak, H .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (06) :470-489
[9]  
Chahine T., 2011, J EXPO SCI ENV EPIDE
[10]  
CRAIN EF, 1994, PEDIATRICS, V94, P356