Post-dryout heat transfer analysis model with droplet Lagrangian simulation

被引:0
作者
Matsuura, K
Kataoka, I
Mishima, K
机构
[1] Nucl Fuel Ind Ltd, Osaka 5900481, Japan
[2] Osaka Univ, Grad Sch Engn, Dept Mech Engn, Suita, Osaka 5650871, Japan
[3] Kyoto Univ, Inst Res Reactor, Sennan, Osaka 5900494, Japan
关键词
non-equilibrium flow; numerical analysis; heat transfer; multi-phase flow; post-dryout; dispersed flow;
D O I
10.1299/jsmeb.49.377
中图分类号
O414.1 [热力学];
学科分类号
摘要
Post-dryout heat transfer analysis was carried Out considering droplet behavior by using the Lagrangian simulation method. Post-dryout heat transfer is an important heat transfer mechanism in many industrial appliances. Especially in recent Japanese BWR licensing. the standard for assessing the integrity of fuel that has experienced boiling transition is being examined. Although post-dryout heat transfer analysis is important when predicting wall temperature, it is difficult to accurately predict the heat transfer coefficient in the post-dryout regime because of the many heat transfer paths and non-equilibrium status between droplet and vapor. Recently, an analysis model that deals with many heat transfer paths including droplet direct contact heat transfer was developed and its results showed good agreement with experimental results. The model also showed that heat transfer by droplet could not be neglected in the low mass flux condition. However, the model deals with droplet deposition behavior by experimental droplet deposition correlation, so it cannot estimate the effect of droplet flow on turbulent flow field and heat transfer. Therefore, in this study we deal with many droplets separately by using the Lagrangian simulation method and hence estimate the effect of droplet flow on the turbulent flow field. We analyzed post-dryout experimental results and found that they con-elated well with the analysis results.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 18 条
[1]  
*AT ENG SOC JAP, 2003, AESJSCP0002
[2]   PARTICLE-SOURCE IN CELL (PSI-CELL) MODEL FOR GAS-DROPLET FLOWS [J].
CROWE, CT ;
SHARMA, MP ;
STOCK, DE .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1977, 99 (02) :325-332
[3]  
Evans D.G., 1983, NUREGCR3363
[4]  
Gosman A.D., 1981, AIAA 19 AER SCI M, P1
[5]  
GOTTULA RC, 1983, ASME JSME THERM ENG, P151
[6]   Turbulent dispersion of particles using eddy interaction models [J].
Graham, DI ;
James, PW .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (01) :157-175
[7]   POST-DRYOUT HEAT-TRANSFER - PHYSICAL MECHANISMS AND A SURVEY OF PREDICTION METHODS [J].
GROENEVELD, DC .
NUCLEAR ENGINEERING AND DESIGN, 1975, 32 (03) :283-294
[8]   A non-equilibrium mechanistic heat transfer model for post-dryout dispersed flow regime [J].
Guo, Y ;
Mishima, K .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (6-7) :861-869
[9]  
Hewitt G.F., 1992, POSTDRYOUT HEAT TRAN
[10]  
Launder B.E, 1972, LECT MATH MODELS TUR