Intra- and Interscanner Reliability and Reproducibility of 3D Whole-Brain Pseudo-Continuous Arterial Spin-Labeling MR Perfusion at 3T

被引:104
作者
Wu, Bing [1 ]
Lou, Xin [2 ]
Wu, Xinhuai [1 ]
Ma, Lin [2 ]
机构
[1] Beijing Mil Gen Hosp, Dept Radiol, Beijing, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Dept Radiol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
cerebral blood flow; arterial spin labeling; reproducibility; repeatability; pCASL; CEREBRAL-BLOOD-FLOW; ACQUISITION TIME; 3.0; T; PRECISION; INVERSION; PCASL;
D O I
10.1002/jmri.24175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo assess the reliability and reproducibility of pseudo-continuous arterial spin labeling (pCASL). Intra- and interscanner reliability and reproducibility are essential before pooling perfusion imaging data. Materials and MethodsEight volunteers were scanned three times on two 3.0T magnetic resonance imaging (MRI) scanners using the pCASL technique. The first and third tests were conducted on scanner one, while the second test was on scanner two. The pCASL was acquired with postlabeling delay time (PLD) of 1.5 and 2.5 seconds. The cerebral blood flow (CBF) of gray matter, white matter, frontal lobe, parietal lobe, occipital lobe, temporal lobe, putamen, posterior cingulate, and thalamus were extracted for comparison. Reliability and reproducibility were measured using the intraclass correlation coefficient (ICC) and within-subject coefficients of variation (wsCV), respectively. ResultsThe pCASL consistently had high intra- and interscanner measurement reliability and reproducibility. Reproducibility of the CBF values was higher, with PLD 2.5 seconds than with PLD 1.5 seconds. Different PLDs had considerable influence on the reproducibility of the different regions of the brain. ConclusionAlthough excellent intra- and interscanner reliability and reproducibility could support the feasibility of cross-site pooling of ASL data, pCASL with multiple PLDs may better assess the CBF of the human brain. J. Magn. Reson. Imaging 2014;39:402-409. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 27 条
  • [1] Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    Alsop, DC
    Detre, JA
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) : 1236 - 1249
  • [2] Binnewijzend MA, 2012, RADIOLOGY
  • [3] Statistics notes: Measurement error proportional to the mean .23.
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 313 (7049) : 106 - 106
  • [4] Arterial spin labeling perfusion MRI at multiple delay times: a correlative study with H215O positron emission tomography in patients with symptomatic carotid artery occlusion
    Bokkers, Reinoud P. H.
    Bremmer, Jochem P.
    van Berckel, Bart N. M.
    Lammertsma, Adriaan A.
    Hendrikse, Jeroen
    Pluim, Josien P. W.
    Kappelle, L. Jaap
    Boellaard, Ronald
    Klijn, Catharina J. M.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2010, 30 (01) : 222 - 229
  • [5] Test-Retest Reliability of Arterial Spin Labeling With Common Labeling Strategies
    Chen, Yufen
    Wang, Danny J. J.
    Detre, John A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 940 - 949
  • [6] Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields
    Dai, Weiying
    Garcia, Dairon
    de Bazelaire, Cedric
    Alsop, David C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1488 - 1497
  • [7] Minimizing acquisition time of arterial spin labeling at 3T
    Fernandez-Seara, Maria A.
    Edlow, Brian L.
    Hoang, Angela
    Wang, Jiongjiong
    Feinberg, David A.
    Detre, John A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1467 - 1471
  • [8] Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories
    Floyd, TF
    Ratcliffe, SJ
    Wang, JJ
    Resch, B
    Detre, JA
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) : 649 - 655
  • [9] Efficiency of inversion pulses for background suppressed arterial spin labeling
    Garcia, DM
    Duhamel, G
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 366 - 372
  • [10] Acquisition Time and Reproducibility of Continuous Arterial Spin-Labeling Perfusion Imaging at 3T
    Gevers, S.
    Majoie, C. B. L. M.
    van den Tweel, X. W.
    Lavini, C.
    Nederveen, A. J.