Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i

被引:19
作者
Buoro, Sabrina [1 ]
Esposito, Sara Apassiti [1 ]
Alessio, MariaGrazia [1 ]
Crippa, Alberto [1 ]
Ottomano, Cosimo [2 ]
Lippi, Giuseppe [2 ]
机构
[1] Hosp Papa Giovanni XXIII, Clin Chem Lab, Sq OMS 1, I-24128 Bergamo, Italy
[2] Acad Hosp Parma, Lab Clin Chem & Hematol, Parma, Italy
关键词
cerebrospinal fluid; automated cell counting; white blood cells; red blood cells; body fluids Sysmex UF-1000i-BF; ACUTE LYMPHOBLASTIC-LEUKEMIA; TRAUMATIC LUMBAR PUNCTURE; BLOOD-CELLS; HEMATOLOGY ANALYZER; XE-5000; YEAST; PERFORMANCE; VALIDATION; CHILDREN; BLASTS;
D O I
10.1002/jcla.21866
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We evaluated the new body fluid module on Sysmex UF1000i (UF1000i-BF) for analysis of white blood cell (WBC) and red blood cell (RBC) in cerebrospinal fluid (CSF). Methods: WBC and RBC counting were compared between UF1000i-BF and Fuchs-Rosenthal counting chamber in 67 CSF samples. This study also included the evaluation of between-day precision, limit of blank (LoB), limit of detection (LoD), functional sensitivity (limit of quantitation, LoQ), carryover and linearity. Diagnostic agreement for differentiation between normal and increased WBC counts (>= 5.0 x 10(6)/L) was also assessed. Results: The agreement between UF1000i-BF and manual WBC counts was otpiaml in all CSF samples (r = 0.99; y = 1.05x + 0.09). A modest overestimation was noticed in samples with WBC < 30 x 10(6)/L (r = 0.95; y = 1.21x -0.15). A good agreement was observed for RBC counts (r = 0.98; y = 1.15x + 0.55), particularly in samples with RBC >= 18 x 10(6)/L (r = 0.98; y = 1.01x + 8.90). Between-day precision was good, with coefficient of variations (CVs) lower than 7.2% for both WBC and RBC. The LoBs were 0.1 x 10(6) WBC/L and 1.2 x 10(6) RBC/L, the LoDs were 0.7 x 10(6) WBC/L and 5.5 x 10(6) RBC/L, the LoQswere 2.4x10(6) WBC/L and 18.0 x 10(6) RBC/L, respectively. Linearity was excellent (r = 1.00 for bothWBC and RBC). Carryover was negligible. Excellent diagnostic agreement was obtained at 4.5 x 10(6) WBC/L cut-off (sensitivity, 100%; specificity, 97.4%). Conclusion: The UF1000i-BF provides rapid and accurate WBC and RBC counts in clinically relevant values of CSF cells. The use of UF1000i-BF may hence allow to replace routine optical counting, except for samples displaying abnormal WBC counts or abnormal scattergram distribution, for which differential cell counts may still be required. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:381 / 391
页数:11
相关论文
共 35 条
[1]  
[Anonymous], 2003, STAT METHODS RATES P, DOI DOI 10.1002/0471445428.CH18
[2]  
[Anonymous], CLIN CHEM LAB MED
[3]  
[Anonymous], 2006, H56A CLSI
[4]  
[Anonymous], 2012, CLSI Document EP17-A2
[5]  
[Anonymous], 2003, EP06A CLSI
[6]  
[Anonymous], 2013, J MED BIOCHEM
[7]   Automated flow cytometric analysis of blood cells in cerebrospinal fluid - Analytic performance [J].
Aune, MW ;
Becker, JL ;
Brugnara, C ;
Canfield, W ;
Dorfman, DM ;
Fiehn, W ;
Fischer, G ;
Fitzpatrick, P ;
Flaming, TH ;
Henriksen, HK ;
Kunicka, JE ;
Lackner, KJ ;
Minchello, E ;
Mullenix, PA ;
Myers, M ;
Petersen, A ;
Ternstrom, W ;
Wilson, S .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (05) :690-700
[8]   Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid [J].
Boer, Klas ;
Deufel, Thomas ;
Reinhoefer, Mike .
CLINICAL BIOCHEMISTRY, 2009, 42 (7-8) :684-691
[9]   ICSH guidelines for the verification and performance of automated cell counters for body fluids [J].
Bourner, G. ;
De la Salle, B. ;
George, T. ;
Tabe, Y. ;
Baum, H. ;
Culp, N. ;
Keng, T. B. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (06) :598-612
[10]   Effects of yeast on automated cell counting [J].
Branda, John A. ;
Kratz, Alexander .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 126 (02) :248-254