Experimental research on intraocular aqueous flow by PIV method

被引:6
作者
Yang, Hongyu [1 ]
Song, Hongfang [1 ]
Mei, Xi [1 ]
Li, Lin [1 ]
Fu, Xineng [2 ]
Zhang, Mindi [2 ]
Liu, Zhicheng [1 ]
机构
[1] Capital Med Univ, Sch Biomed Engn, Beijing 100069, Peoples R China
[2] Beijing Inst Technol, Sch Mech & Vehicular Engn, Beijing 100081, Peoples R China
来源
BIOMEDICAL ENGINEERING ONLINE | 2013年 / 12卷
基金
中国国家自然科学基金;
关键词
Aqueous humor flow; PIV; Flow field; Velocity vector; ANTERIOR-CHAMBER; FLUID-FLOW; HUMOR;
D O I
10.1186/1475-925X-12-108
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Aqueous humor flows regularly from posterior chamber to anterior chamber, and this flow much involves intraocular pressure, the eye tissue nutrition and metabolism. Purpose: To visualize and measure the intraocular flow regular pattern of aqueous humor. Method: Intraocular flow in the vitro eyeball is driven to simulate the physiological aqueous humor flow, and the flow field is measured by Particle Image Velocimetry (PIV). Fluorescent particle solution of a certain concentration was infused into the root of Posterior Chamber(PC) of vitro rabbit eye to simulate the generation of aqueous and was drained out at a certain hydrostatic pressure from the angle of Anterior Chamber(AC) to represent the drainage of aqueous. PIV method was used to record and calculate the flow on the midsagittal plane of the eyeball. Results: Velocity vector distribution in AC has been obtained, and the distribution shows symmetry feature to some extent. Fluorescent particle solution first fills the PC as it is continuously infused, then surges into AC through the pupil, flows upwards toward the central cornea, reflecting and scattering, and eventually converges along the inner cornea surface towards the outflow points at the periphery of the eyeball. Velocity values around the pupillary margin are within the range of 0.008-0.012 m/s, which are close to theoretical values of 0.0133 m/s, under the driving rate of 100 mu l/min. Conclusions: Flow field of aqueous humor can be measured by PIV method, which makes it possible to study the aqueous humor dynamics by experimental method. Our study provides a basis for experimental research on aqueous humor flow; further, it possibly helps to diagnose and treat eye diseases as shear force damage of ocular tissues and destructions on corneal endothelial cells from the point of intraocular flow field.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] PIV measurements of intake flow field in axial-flow pump
    Liu, Chao
    Liang, Haojie
    Jin, Yan
    Yang, Fan
    Chen, Feng
    Yang, Hua
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (08): : 33 - 41
  • [32] EXPERIMENTAL STUDY OF FLOW STRUCTURE BEHIND A CIRCULAR CYLINDER WITH WAVY SURFACE BY PIV
    Daichin
    Journal of Hydrodynamics, 2006, (01) : 97 - 103
  • [33] Experimental study on turbulent swirling flow in a cylindrical annuli by using the PIV technique
    Chang, TH
    INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2004, 5 (01) : 17 - 22
  • [34] Experimental study of the flow characteristics in an automotive HVAC system using a PIV technique
    H. S. Ji
    S. J. Lee
    International Journal of Automotive Technology, 2009, 10 : 561 - 566
  • [35] EXPERIMENTAL STUDY OF THE FLOW CHARACTERISTICS IN AN AUTOMOTIVE HVAC SYSTEM USING A PIV TECHNIQUE
    Ji, H. S.
    Lee, S. J.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2009, 10 (05) : 561 - 566
  • [36] An experimental study on the flow structure inside a display cooler using PIV techniques
    Park, Cheol-Woo
    Baek, In-Je
    Yoon, Jong-Hwan
    Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 : 167 - 170
  • [37] PIV experimental research on gasper jets interacting with the main ventilation in an aircraft cabin
    Li, Jiayu
    Liu, Junjie
    Dai, Shen
    Guo, Yong
    Jiang, Nan
    Yang, William
    BUILDING AND ENVIRONMENT, 2018, 138 : 149 - 159
  • [38] PIV Measurements of the Flow in a Rotating Cavity with a Radial Inflow
    Yu, X.
    Luo, X.
    Sun, J. N.
    Xu, G. Q.
    Deng, H. W.
    Shen, E. N.
    HEAT TRANSFER RESEARCH, 2010, 41 (07) : 787 - 799
  • [39] PIV METHOD AND NUMERICAL COMPUTATION FOR PREDICTION OF LIQUID STEEL FLOW STRUCTURE IN TUNDISH
    Cwudzinski, A.
    ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (01) : 11 - 17
  • [40] Measurements of flow hydrodynamics in a jet-loop reactor using PIV method
    Ludwig, W.
    Szafran, R. G.
    Kmiec, A.
    Dziak, J.
    CHISA 2012, 2012, 42 : 1157 - 1168