Reduction of electronic noise from radiofrequency generator during radiofrequency ablation in interventional MRI

被引:16
作者
Oshiro, T [1 ]
Sinha, U [1 ]
Lu, D [1 ]
Sinha, S [1 ]
机构
[1] Univ Calif Los Angeles, Med Ctr, Dept Radiol Sci, Sch Med, Los Angeles, CA 90024 USA
关键词
magnetic resonance imaging; interventional radiofrequency ablation; artifacts; noise;
D O I
10.1097/00004728-200203000-00025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MRI has been used increasingly in the recent past for the guidance and monitoring of minimally invasive interventional procedures, using typically radiofrequency (RF) and laser energy, cryoablation, and percutaneous ethanol. RF energy has been used over the last 30 years for the ablation of tissues. Its use in conjunction with MRI for monitoring is limited, however. because of the electronic noise produced by the RF generators, which can significantly deteriorate image quality. The objective of this work was to devise methods by which this noise can be reduced to an acceptable level to allow simultaneous acquisition of MR images for monitoring purposes with the application of RF energy. Three different methods of noise reduction were investigated in a 0.2 T MR scanner: filtration using external hardware circuitry, MR scanner,software-control led filtration, and keyholing. The last two methods were unable by themselves to suppress the noise to an acceptable degree. Hardware filtration, however. provides excellent suppression of RF noise and is able to withstand up to 12 W of RF energy. When all the three approaches are combined, significant reduction of RF noise is achieved. The feasibility of creating an RF lesion of about 1.2 cm diameter in vivo in a porcine model simultaneously with temperature-sensitive MRI with adequate noise suppression is demonstrated.
引用
收藏
页码:308 / 316
页数:9
相关论文
共 22 条
[1]  
[Anonymous], 2006, ELECT FILTER DESIGN
[2]   Radiofrequency ablation of brain tumours using MR guidance [J].
Anzai, Y ;
Lufkin, R ;
DeSalles, A ;
Farahani, K ;
Huang, A ;
Sinha, S ;
Behnke, E ;
Black, K .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1996, 5 (03) :232-242
[3]  
ARNOW S, 1960, J NEUROSURG, V17, P431
[4]   MR monitoring of MR-guided radiofrequency thermal ablation of normal liver in an animal model [J].
Boaz, TL ;
Lewin, JS ;
Chung, YC ;
Duerk, JL ;
Clampitt, ME ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :64-69
[5]  
BROGGI G, 1985, J NEUROSURG SCI, V29, P165
[6]  
DANIEL BL, 1997, MR GUIDED RADIOFREQU
[7]   Transperineal radiofrequency interstitial tumor ablation of the prostate: Correlation of magnetic resonance imaging with histopathologic examination [J].
Djavan, B ;
Zlotta, AR ;
Susani, M ;
Heinz, G ;
Shariat, S ;
Silverman, DE ;
Schulman, CC ;
Marberger, M .
UROLOGY, 1997, 50 (06) :986-992
[8]   Tumor ablation with radio-frequency energy [J].
Gazelle, GS ;
Goldberg, SN ;
Solbiati, L ;
Livraghi, T .
RADIOLOGY, 2000, 217 (03) :633-646
[9]   Radiofrequency as a lesioning model in experimental spinal cord injury [J].
Haghighi, SS ;
PerezEspejo, MA ;
Rodriguez, F ;
Clapper, A .
SPINAL CORD, 1996, 34 (04) :214-219
[10]   A COMPARISON OF RESULTS FROM CENTER-MEDIAN AND BASAL THALAMOTOMIES FOR PAIN [J].
HITCHCOCK, ER ;
TEIXEIRA, MJ .
SURGICAL NEUROLOGY, 1981, 15 (05) :341-351