摘要
Aims: The mandibular incisive nerve can be subjected to iatrogenic injury during bone graft harvesting. Using cone beam computed tomography (CBCT), this study aims to determine a safe zone for bone graft harvesting that avoids injuring this nerve. Methods: Sixty CBCT examinations of patients were included in this study. The examinations were taken using the i-CAT CBCT imaging system, applying a standardized exposure protocol. Image reconstruction from the raw data was performed using the SimPlant dental implant software. The distances of mandibular incisive canal (MIC) to the inferior border and the labial and lingual cortices of the mandible were measured at 3, 5, 7 and 9mm mesial to the mental foramen. Results: The MIC was visible in all (100%) CBCT images. The median distance and interquartile range from the lower border of the mandible was 9.86 (2.51) mm, curving downwards toward the inferior mandibular border at the symphysis menti. It was located closer to the buccal border of the mandible (3.15 [1.28] mm) than lingual cortex (4.78 [2.0] mm). The MIC curves toward the lingual side at the symphysis menti. There was gender difference in a number of these measurements. Current recommendation for chin bone graft harvesting can be applied to Asian subjects. Conclusions: While acknowledging that there is human variability, this study provides an accurate anatomic location of the MIC, which in turn helps to determine a safe zone for chin bone graft harvesting. This information can become a useful guide in centers where CBCT is not available.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 27 条
[1]  
Bovi M, 2005, INT J PERIODONT REST, V25, P375
[2]  
De Andrade E, 2001, INT J PERIODONT REST, V21, P591
[3]   Bone, grafts and bone graft substitutes in orthopedic trauma surgery - A critical analysis [J].
De Long, William G., Jr. ;
Einhorn, Thomas A. ;
Koval, Kenneth ;
McKee, Michael ;
Smith, Wade ;
Sanders, Roy ;
Watson, Tracy .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03) :649-658
[4]   IMPLANT PLACEMENT IN THE ATROPHIC MANDIBLE - AN ANATOMIC STUDY [J].
DENISSEN, HW ;
VELDHUIS, HA ;
VANFAASSEN, F .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (02) :260-263
[5]  
Doran D, 2004, J ORAL MAXILLOFACIAL, V62, pS37, DOI [10.1016/j.joms.2004.05.169, DOI 10.1016/J.JOMS.2004.05.169]
[6]  
Hajnis Karle, 1994, P201
[7]   THE CHIN AS A DONOR SITE IN EARLY SECONDARY OSTEOPLASTY - A RETROSPECTIVE CLINICAL AND RADIOLOGICAL EVALUATION [J].
HOPPENREIJS, TJM ;
NIJDAM, ES ;
FREIHOFER, HPM .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1992, 20 (03) :119-124
[8]  
Hunt DR, 1999, INT J PERIODONT REST, V19, P165
[9]   Appearance of the mandibular incisive canal on panoramic radiographs [J].
Jacobs, R ;
Mraiwa, N ;
van Steenberghe, D ;
Sanderink, G ;
Quirynen, M .
SURGICAL AND RADIOLOGIC ANATOMY, 2004, 26 (04) :329-333
[10]   Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan [J].
Jacobs, R ;
Mraiwa, N ;
vanSteenberghe, D ;
Gijbels, F ;
Quirynen, M .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (05) :322-327