Interventional radiology in hemodialysis fistulae and grafts: A multidisciplinary approach

被引:62
作者
Turmel-Rodrigues, L [1 ]
Pengloan, J [1 ]
Bourquelot, P [1 ]
机构
[1] Clin St Gatien, Dept Cardiovasc Radiol, F-37000 Tours, France
关键词
dialysis shunts; veins; transluminal angioplasty; stents and prostheses; grafts; stenosis or thrombosis; thrombolysis;
D O I
10.1007/s00270-001-0082-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To review the place of interventional radiology in arteriovenous access for hemodialysis. Methods: Prophylactic dilation of stenoses greater than 50% associated with clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. Stents are placed only in selected cases with clearly insufficient results of dilation but they must never overlap major side veins and obviate future access creation. Thrombosed fistulae and grafts can be declotted by purely mechanical methods or in combination with a lytic drug. Results: The success rates are over 90% for dilation, with frequent resort to stents in central veins. Long-term results in the largest series are better in forearm native fistulae compared with grafts (best 1-year primary patency: 51% versus 40%). The success rates for declotting are better in grafts compared with forearm fistulae but early rethrombosis is frequent in grafts so that primary patency rates can be better for native fistulae from the first month's follow-up (best 1-year primary patency: 49% versus 26%). Conclusion: Radiology achieves results comparable with surgery, with minimal invasiveness and better venous preservation. However, wide variations in the results suggest that the degree of commitment of physicians might be as important as the type of technique used.
引用
收藏
页码:3 / 16
页数:14
相关论文
共 120 条
  • [1] A multidisciplinary approach to hemodialysis access: Prospective evaluation
    Allon, M
    Bailey, R
    Ballard, R
    Deierhoi, MH
    Hamrick, K
    Oser, R
    Rhynes, VK
    Robbin, ML
    Saddekni, S
    Zeigler, ST
    [J]. KIDNEY INTERNATIONAL, 1998, 53 (02) : 473 - 479
  • [2] Improvement in hemodialysis vascular access outcomes in a dedicated access center
    Arnold, WP
    [J]. SEMINARS IN DIALYSIS, 2000, 13 (06) : 359 - 363
  • [3] Quality improvement guidelines for percutaneous management of the thrombosed or dysfunctional dialysis access
    Aruny, JE
    Lewis, CA
    Cardella, JF
    Cole, PE
    Davis, A
    Drooz, AT
    Grassi, CJ
    Gray, RJ
    Husted, JW
    Jones, MT
    McCowan, TC
    Meranze, SG
    Van Moore, A
    Neithamer, CD
    Oglevie, SB
    Omary, RA
    Patel, NH
    Rholl, KS
    Roberts, AC
    Sacks, D
    Sanchez, O
    Silverstein, MI
    Singh, H
    Swan, TL
    Towbin, RB
    Trerotola, SO
    Bakal, CW
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (04) : 491 - 498
  • [4] Changes in the practice of angioaccess surgery: Impact of dialysis outcome and quality initiative recommendations
    Ascher, E
    Gade, P
    Hingorani, A
    Mazzariol, F
    Gunduz, Y
    Fodera, M
    Yarkovich, W
    [J]. JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) : 84 - 90
  • [5] Hydrodynamic thrombectomy system versus pulse-spray thrombolysis for thrombosed hemodialysis grafts: A multicenter prospective randomized comparison
    Barth, KH
    Gosnell, MR
    Palestrant, AM
    Martin, LG
    Siegel, JB
    Matalon, TAS
    Goodwin, SC
    Neese, PA
    Swan, TL
    Uflacker, R
    [J]. RADIOLOGY, 2000, 217 (03) : 678 - 684
  • [6] GIANTURCO SELF-EXPANDING STENT IN THE TREATMENT OF STENOSIS IN DIALYSIS ACCESS GRAFTS
    BEATHARD, GA
    [J]. KIDNEY INTERNATIONAL, 1993, 43 (04) : 872 - 877
  • [7] Mechanical thrombolysis for the treatment of thrombosed hemodialysis access grafts
    Beathard, GA
    Welch, BR
    Maidment, HJ
    [J]. RADIOLOGY, 1996, 200 (03) : 711 - 716
  • [8] Salvage of the nonfunctioning arteriovenous fistula
    Beathard, GA
    Settle, SM
    Shields, MW
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (05) : 910 - 916
  • [9] PERCUTANEOUS TRANSVENOUS ANGIOPLASTY IN THE TREATMENT OF VASCULAR ACCESS STENOSIS
    BEATHARD, GA
    [J]. KIDNEY INTERNATIONAL, 1992, 42 (06) : 1390 - 1397
  • [10] UTILITY OF INTRA-ACCESS PRESSURE MONITORING IN DETECTING AND CORRECTING VENOUS OUTLET STENOSES PRIOR TO THROMBOSIS
    BESARAB, A
    SULLIVAN, KL
    ROSS, RP
    MORITZ, MJ
    [J]. KIDNEY INTERNATIONAL, 1995, 47 (05) : 1364 - 1373