Evaluation of 3D-Printed titanium alloy using eddy current testing with high-sensitivity magnetic sensor

被引:18
作者
He, Dongfeng [1 ]
Wang, Zhi [1 ,2 ]
Kusano, Masahiro [1 ]
Kishimoto, Satoshi [1 ]
Watanabe, Makoto [1 ]
机构
[1] Natl Inst Mat Sci, 1-2-1 Sengen, Tsukuba, Ibaraki 3050047, Japan
[2] Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing, Peoples R China
关键词
MULTIFREQUENCY;
D O I
10.1016/j.ndteint.2018.11.007
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We developed ECT systems using high-sensitivity magnetic sensors with small size; and used the systems to evaluate a titanium alloy sample prepared by a 3D laser printer. Two systems were used. In the first system, a small excitation coil was wrapped around the amorphous wire, and the excitation frequency was chosen to be 100 kHz. In the second system, a large circular coil was used to surround the test sample, and the excitation frequency was chosen to be 70 kHz. The image of the scanning result shows that both ECT excitation methods were able to detect the positions of flaws in the test sample. Moreover, the sizes of the flaws could be seen in the phase image result of the first ECT excitation method, and the interaction between the eddy current and the flaws could be observed in the amplitude imaging result of the second ECT excitation method. We also compared the results with that of traditional inductive coil ECT system.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 23 条
[1]   Measurement of crack-induced non-propagating Lamb wave modes under varying crack widths [J].
An, Yun-Kyu .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2015, 62 :134-143
[2]   Improving Performance of GMR Sensors [J].
Bernieri, Andrea ;
Betta, Giovanni ;
Ferrigno, Luigi ;
Laracca, Marco .
IEEE SENSORS JOURNAL, 2013, 13 (11) :4513-4521
[3]   An experimental comparison of multi-frequency and chirp excitations for eddy current testing on thin defects [J].
Betta, Giovanni ;
Ferrigno, Luigi ;
Laracca, Marco ;
Burrascano, Pietro ;
Ricci, Marco ;
Silipigni, Giuseppe .
MEASUREMENT, 2015, 63 :207-220
[4]   GMR-Based ECT Instrument for Detection and Characterization of Crack on a Planar Specimen: A Hand-Held Solution [J].
Betta, Giovanni ;
Ferrigno, Luigi ;
Laracca, Marco .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (02) :505-512
[5]   Magneto-Impedance Biosensor With Enhanced Sensitivity for Highly Sensitive Detection of Nanomag-D Beads [J].
Devkota, Jagannath ;
Ruiz, Alejandro ;
Mukherjee, Pritish ;
Srikanth, Hariharan ;
Manh-Huong Phan .
IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (07) :4060-4063
[6]   A Fully Non-Contact Ultrasonic Propagation Imaging System for Closed Surface Crack Evaluation [J].
Dhital, D. ;
Lee, J. R. .
EXPERIMENTAL MECHANICS, 2012, 52 (08) :1111-1122
[7]   Detection of flaws in ferromagnetic samples based on low frequency eddy current imaging [J].
Fujita, Y ;
Sasada, I .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :8277-8279
[8]   Non-Destructive Techniques Based on Eddy Current Testing [J].
Garcia-Martin, Javier ;
Gomez-Gil, Jaime ;
Vazquez-Sanchez, Ernesto .
SENSORS, 2011, 11 (03) :2525-2565
[9]  
He DF, 2015, I CONF SENS TECHNOL, P543, DOI 10.1109/ICSensT.2015.7438457
[10]   Development of eddy current testing system for inspection of combustion chambers of liquid rocket engines [J].
He, D. F. ;
Zhang, Y. Z. ;
Shiwa, M. ;
Moriya, S. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (01)