A Pilot Study Evaluating Liquid-Based Fine Needle Aspiration Cytology of Breast Lesions: A Cytomorphological Comparison of Sure Path® Liquid-Based Preparations and Conventional Smears

被引:20
作者
Ryu, Han Suk [1 ]
Park, In Ae [1 ]
Park, So Yeon [2 ]
Jung, Yoon Yang [3 ]
Park, Sung Hee [4 ]
Shin, Hee-Chul [5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Pathol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Bundang Hosp, Songnam, South Korea
[3] Chung Ang Univ, Coll Med, Chung Ang Univ Hosp, Dept Pathol, Seoul 156756, South Korea
[4] Chung Ang Univ, Coll Med, Chung Ang Univ Hosp, Dept Radiol, Seoul 156756, South Korea
[5] Chung Ang Univ, Coll Med, Chung Ang Univ Hosp, Dept Surg, Seoul 156756, South Korea
关键词
Breast; Cytomorphology; Fine needle aspiration cytology; Liquid-based cytology; SurePath (R); THIN-LAYER; BIOPSY; EXPERIENCE;
D O I
10.1159/000351306
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objective: Fine needle aspiration cytology (FNAC) is recommended by the World Health Organization as a diagnostic method for breast lesions. The morphological interpretation of liquid-based preparations (LBPs) remains a diagnostic challenge due to considerably altered cytomorphology. The aim of the current study was to compare cytomorphological characteristics of SurePath (R) (SP)-based LBP and conventional smear (CS) in breast FNACs. Study Design: The study included 77 benign and 60 malignant breast FNACs obtained by both SP and CS, all with tissue confirmation. Cases analyzed with both preparations were reviewed and compared, focusing on 10 cytomorphological features. Results: SP aspirates demonstrated notable cytomorphological alterations. Among them, a prominent three-dimensional configuration of cell clusters and frequent and conspicuous nucleoli were the most prominent characteristics of SP compared with CS. Overall diagnostic performances were comparable but were slightly lower for SP than CS (diagnostic accuracy of two reviewers; 87.6 and 90.5% for SP vs. 91.2 and 92.7% for CS, respectively). Conclusion: Although the reviewer should be aware of distinctive cytomorphological alterations, the SP technique is reliable for the evaluation of breast lesions with the advantage of easy interpretation and a diagnostic accuracy equivalent to CS. Copyright (C) 2013 S. Karger AG, Basel
引用
收藏
页码:391 / 399
页数:9
相关论文
共 50 条
  • [31] Comparative Analysis of Liquid based and Conventional Cytology Smears in Fine Needle Aspirates from Breast Lesions
    Sharma, Vasundhara
    Gupta, Veena
    Parmar, Padam
    Jain, Promil
    Thakran, Deepak
    Sen, Rajeev
    JOURNAL OF CYTOLOGY, 2019, 36 (02) : 89 - 93
  • [32] Comparison of liquid-based cytology cervical smears with histopathological findings
    Hascicek, Seyhan Ozakkoyunlu
    Oguzsoy, Tuba
    Eken, Kamile Gulcin
    Kabukcuoglu, Fevziye
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2018, 9 (05) : 359 - 362
  • [33] A Prospective Comparison of Liquid-Based Cytology and Traditional Smear Cytology in Pancreatic Endoscopic Ultrasound-Guided Fine Needle Aspiration
    Lee, Jun Kyu
    Choi, E. Ryoung
    Jang, Tae Hoon
    Chung, Yun Hee
    Jang, Kee-Taek
    Park, Sang-Mo
    Lee, Jong Kyun
    Lee, Kyu Taek
    Lee, Kwang Hyuck
    ACTA CYTOLOGICA, 2011, 55 (05) : 401 - 407
  • [34] Comparison of Conventional Smear and Liquid-Based Cytology in Adequacy of Thyroid Fine-Needle Aspiration Biopsies without an Accompanying Cytopathologist
    Sayer, Ayse Ozdal
    Mut, Deniz Turkyilmaz
    Von Bodelschwingh, Bade
    Ozguven, Banu Yilmaz
    Sahin, Cennet
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2022, 56 (03): : 353 - 359
  • [35] Efficacy of liquid-based cytology versus conventional smears in FNA samples
    Tripathy, Kalpalata
    Misra, Aparajita
    Ghosh, Joydip Kumar
    JOURNAL OF CYTOLOGY, 2015, 32 (01) : 17 - 20
  • [36] Primary pure squamous cell carcinoma of the breast diagnosed by fine-needle aspiration cytology:: A case study using liquid-based cytology
    Vera-Alvarez, J.
    Garcia-Prats, M. D.
    Marigil-Gomez, M.
    Abascal-Agorreta, M.
    Lopez-Lopez, J. I.
    Ramon-Cajal, J. M.
    DIAGNOSTIC CYTOPATHOLOGY, 2007, 35 (07) : 429 - 432
  • [37] An audit of the accuracy of fine needle aspiration using a liquid-based cytology system in the setting of a rapid access breast clinic
    Joseph, L
    Edwards, JM
    Nicholson, CM
    Pitt, MA
    Howat, AJ
    CYTOPATHOLOGY, 2002, 13 (06) : 343 - 349
  • [38] Expression of p63 immunostaining in liquid-based cytology (BD SurePath) of breast fine-needle aspiration
    Osugi, Masumi
    Kinoshita, Kosei
    Sugita, Atsuro
    Kito, Katsumi
    Maeda, Toshiharu
    DIAGNOSTIC CYTOPATHOLOGY, 2018, 46 (10) : 845 - 852
  • [39] Comparison of Conventional Smear and Liquid-based Cytology Preparation in Diagnosis of Lung Cancer by Bronchial Wash and Transbronchial Needle Aspiration
    Nalwa, Aasma
    Walia, Ritika
    Singh, Varsha
    Madan, Karan
    Mathur, Sandeep
    Iyer, Venkateshwaran
    Jain, Deepali
    JOURNAL OF CYTOLOGY, 2018, 35 (02) : 94 - 98
  • [40] Use of conventional smears versus liquid-based preparations for fine-needle aspirate specimens: The time has not come to abandon your conventional smears!
    Faquin, William C.