Monte Carlo simulation to evaluate the contamination in an energy modulated carbon ion beam for hadron therapy delivered by cyclotron

被引:2
作者
Morone, M. Cristina [1 ,2 ]
Calabretta, Luciano
Cuttone, Giacomo
Fiorini, Francesca [3 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Biopatol & Diagnost Immagini, I-00173 Rome, Italy
[2] Ist Nazl Fis Nucl, Sez Roma Tor Vergata, Rome, Italy
[3] Univ Roma Tor Vergata, Dipartimento Fis, I-00173 Rome, Italy
关键词
D O I
10.1088/0031-9155/53/21/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Protons and carbon ion beams for hadron therapy can be delivered by cyclotrons with a fixed energy. In order to treat patients, an energy degrader along the beam line will be used to match the particle range with the target depth. Fragmentation reactions of carbon ions inside the degrader material could introduce a small amount of unwanted contaminants to the beam, giving additional dose to the patient out of the target volume. A simulation study using the FLUKA Monte Carlo code has been carried out by considering three different materials as the degrader. Two situations have been studied: a realistic one, lowering the carbon beam energy from 300 MeV/n to 220 MeV/n, corresponding to a range of 10 cm in water, and the worst possible case, lowering the carbon energy to 50 MeV/n, corresponding to the millimeter range. The main component of the contaminant is represented by alpha particles and protons, with a typical momentum after the degrader greater than that of the primary beam, and can be eliminated by the action of a momentum analyzing system and slits, and by a second thin absorber. The residual component of fragments reaching the patient is negligible with respect to the fragment quantity generated by the primary beam inside the patient before arriving at the end of the target volume.
引用
收藏
页码:6045 / 6053
页数:9
相关论文
共 10 条
[1]  
BATTISTONI G, 2008, NUOVO CIMEN IN PRESS
[2]   Emission of Li, 7,9Be and B fragments in the interaction of 12C with 93Nb between 200 and 400 MeV [J].
Becker, B ;
Albertini, F ;
Gadioli, E ;
Steyn, GF ;
Cavinato, M ;
Connell, SH ;
Cowley, AA ;
Fabrici, E ;
Förtsch, SV ;
Erba, EG ;
Lawrie, JJ ;
Haddad, ES .
EUROPEAN PHYSICAL JOURNAL A, 2003, 18 (04) :639-644
[3]   A novel superconducting cyclotron for therapy and radioisotope production [J].
Calabretta, L ;
Cuttone, G ;
Maggiore, M ;
Re, M ;
Rifuggiato, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02) :1009-1012
[4]  
Cerutti F., 2006, 11 INT C NUCL REACT
[5]  
Fasso A, 2003, COMPUTING HIGH ENERG
[6]  
Ferrari A, 2005, CERN2005102005
[7]   Emission of intermediate-mass fragments in the interaction of 16O with 59Co, 93Nb and 197Au [J].
Gadioli, E ;
Steyn, GF ;
Albertini, F ;
Birattari, C ;
Cavinato, M ;
Connell, SH ;
Cowley, AA ;
Fabrici, E ;
Förtsch, SV ;
Erba, EG ;
Lawrie, JJ ;
Pigni, M ;
Sellschop, JPF ;
Haddad, ES .
EUROPEAN PHYSICAL JOURNAL A, 2003, 17 (02) :195-212
[8]  
HIRAO Y, 2001, 16 INT CYCL C THEIR, P8
[9]  
MAIRANI A, 2007, THESIS U STUDI PAVIA
[10]   Investigating the accuracy of the FLUKA code for transport of therapeutic ion beams in matter [J].
Sommerer, Florian ;
Parodi, Katia ;
Ferrari, Alfredo ;
Poljanc, Karin ;
Enghardt, Wolfgang ;
Aiginger, Hannes .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17) :4385-4398