Bonding of ceramic insert to a laboratory particle filler composite

被引:13
作者
Kienanen, P
Alander, P
Lassila, LVJ
Vallittu, PK
机构
[1] Univ Turku, Inst Dent, Dept Prosthet Dent & Biomat Sci, Washington, DC 20520 USA
[2] Helsinki Polytech, Inst Dent Technol, Helsinki, Finland
关键词
D O I
10.1080/00016350510020025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The push-out bond strength of cylindrical ceramic inserts (0) to particulate filler resin composite (VC) was evaluated in this study. Various surface treatments to improve the adhesion of Cl to resin composite were tested. Additionally, the effect of fiber-reinforced composite (FRC) laminate encapsulation around CI was tested. Feldspathic porcelain CI with a diameter of 3.1 mm was bonded to VC. Adhesive resin was used for bonding. In group 1, no surface treatment of CI was done. In group 2, CI was encapsulated with a thin layer of woven glass FRC. In group 3, the surface of the CI was tribochemically silica coated and silanized. In group 4, the surface of the CI was grit-blasted with 50 mu m aluminum oxide and etched with hydrofluoric acid. In group 5, the grit-blasted Cl was encapsulated with a layer of FRC. The specimens (n = 6/group) were either dry stored or thermocycled in water (6000 x 5-55 degrees C). The push-out test was carried out with a universal material testing machine. The highest push-out strength was achieved in group 5 (20.4 MPa) and the lowest in group 2 (11.5 MPa). ANOVA revealed that both surface treatment and storage condition had a significant effect on push-out strength (p < 0.05). We conclude that the additional glass FRC encapsulation can be used to increase the bond strength of insert to composite.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 32 条
[2]   Inserts--megafillers in composite restorations: a literature review. [J].
Federlin M. ;
Thonemann B. ;
Schmalz G. .
Clinical Oral Investigations, 2000, 4 (1) :1-8
[3]  
FENNIS MM, 2005, IN PRESS DENT MAT
[4]   In vitro evaluation of the marginal degradation of dental composites under simulated occlusal loading [J].
Ferracane, JL ;
Condon, JR .
DENTAL MATERIALS, 1999, 15 (04) :262-267
[5]   Finite element and experimental analyses of polymer-based dental bridges reinforced by ceramic bars [J].
Fischer, H ;
Weber, M ;
Eck, M ;
Erdrich, A ;
Marx, R .
JOURNAL OF BIOMECHANICS, 2004, 37 (03) :289-294
[6]  
FRANKENBERGER R, 1998, DTSCH ZAHNARZTLICHE, V53, P139
[7]   Clinical evaluation of fiber-reinforced fixed bridges [J].
Freilich, MA ;
Meiers, JC ;
Duncan, JP ;
Eckrote, KA ;
Goldberg, J .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (11) :1524-1534
[8]   In-vivo evaluation of a feldspathic ceramic system: 2-year results [J].
Friedl, KH ;
Schmalz, G ;
Hiller, KA ;
Saller, A .
JOURNAL OF DENTISTRY, 1996, 24 (1-2) :25-31
[9]   INVITRO 2-BODY WEAR OF 3 VENEERING RESINS [J].
GALLEGOS, LI ;
NICHOLLS, JI .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (02) :172-178
[10]  
Hahn P, 1998, J ORAL REHABIL, V25, P567