Correlation Between Corneal Topographic, Densitometry, and Biomechanical Parameters in Keratoconus Eyes

被引:45
作者
Shen, Yang [1 ,2 ,3 ]
Han, Tian [1 ,2 ,3 ]
Jhanji, Vishal [4 ]
Shang, Jianmin [1 ,2 ,3 ]
Zhao, Jing [1 ,2 ,3 ]
Li, Meiyan [1 ,2 ,3 ]
Zhou, Xingtao [1 ,2 ,3 ]
机构
[1] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[2] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[3] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[4] Univ Pittsburgh, Sch Med, Dept Ophthalmol, Pittsburgh, PA 15261 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 03期
基金
中国国家自然科学基金;
关键词
biomechanics; corneal structure; CorVis ST; keratoconus; Pentacam HR; MATRIX;
D O I
10.1167/tvst.8.3.12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the correlation between corneal densitometry, corneal topographic parameters, and corneal biomechanical properties in keratoconus. Methods: A total of 76 eyes of 76 keratoconus patients were enrolled in this cross-sectional study. Corneal densitometry and topography were measured using Pentacam HR. Corneal biomechanical properties were measured using CorVis ST. Results: The corneal densitometry values of the anterior 0 to 2 and 2 to 6 mm layers significantly correlated with the maximum keratometry values (R = 0373, P = 0.001 and R = 0.276, P = 0.016, respectively), thinnest corneal thickness values (R = -0331, P = 0.003 and R = - 0.234, P = 0.042, respectively), anterior corneal elevation (R = 0.392, P < 0.001 and R = 0.323, P = 0.004, respectively), and posterior corneal elevation (R = 0.450, P < 0.001 and R = 0.367, P = 0.001, respectively). The stiffness parameter-applanation time 1 (SP-A1) significantly correlated with the corneal densitometry values for the anterior 0 to 2 mm (R = -0.397, P < 0.001), anterior 2 to 6 mm (R = -0.331, P = 0.004), central 0 to 2 mm (R = - 0.306, P = 0.007), central 2 to 6 mm (R = - 0.228, P = 0.048), posterior 2 to 6 mm (R = -0.243, P = 0.035), total 0 to 2 mm (R = -0.291, P = 0.011), and total 2 to 6 mm (R = -0.295, P = 0.010) layers. Conclusions: The corneal densitometry values correlated with the severity of keratoconus and the SP-A1 values. Translational Relevance: Corneal densitometry values may serve as markers to predict the severity of keratoconus.
引用
收藏
页数:7
相关论文
共 24 条
  • [1] Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection
    Ambrosio, Renato, Jr.
    Lopes, Bernardo T.
    Faria-Correia, Fernando
    Salomao, Marcella Q.
    Buhren, Jens
    Roberts, Cynthia J.
    Elsheikh, Ahmed
    Vinciguerra, Riccardo
    Vinciguerra, Paolo
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (07) : 434 - +
  • [2] Effect of Pseudoexfoliation on Corneal Transparency
    Cankaya, Ali Bulent
    Tekin, Kemal
    Inanc, Merve
    [J]. CORNEA, 2016, 35 (08) : 1084 - 1088
  • [3] Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus
    de Sanctis, Ugo
    Loiacono, Carlotta
    Richiardi, Lorenzo
    Turco, Davide
    Mutani, Bernardo
    Grignolo, Federico M.
    [J]. OPHTHALMOLOGY, 2008, 115 (09) : 1534 - 1539
  • [4] Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction
    Garzon, Nuria
    Poyales, Francisco
    Illarramendi, Igor
    Mendicute, Javier
    Janez, Oscar
    Caro, Pedro
    Lopez, Alfredo
    Argueso, Francisco
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (06) : 1263 - 1268
  • [5] Jester JV, 1999, J CELL SCI, V112, P613
  • [6] Corneal Biomechanical Properties in Normal, Forme Fruste Keratoconus, and Manifest Keratoconus After Statistical Correction for Potentially Confounding Factors
    Johnson, R. Duncan
    Nguyen, Myhanh T.
    Lee, Nancy
    Hamilton, D. Rex
    [J]. CORNEA, 2011, 30 (05) : 516 - 523
  • [7] INCREASED COLLAGENASE AND GELATINASE ACTIVITIES IN KERATOCONUS
    KAO, WWY
    VERGNES, JP
    EBERT, J
    SUNDARRAJ, CV
    BROWN, SI
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1982, 107 (03) : 929 - 936
  • [8] INCREASED GELATINOLYTIC ACTIVITY IN KERATOCONUS KERATOCYTE CULTURES - A CORRELATION TO AN ALTERED MATRIX METALLOPROTEINASE-2 TISSUE INHIBITOR OF METALLOPROTEINASE RATIO
    KENNEY, MC
    CHWA, M
    OPBROEK, AJ
    BROWN, DJ
    [J]. CORNEA, 1994, 13 (02) : 114 - 124
  • [9] Kenney MC, 1997, CORNEA, V16, P345
  • [10] Increased levels of catalase and cathepsin V/L2 but decreased TIMP-1 in keratoconus corneas: Evidence that oxidative stress plays a role in this disorder
    Kenney, MC
    Chwa, M
    Atilano, SR
    Tran, A
    Carballo, M
    Saghizadeh, M
    Vasiliou, V
    Adachi, W
    Brown, DJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (03) : 823 - 832