Osseointegration of implants with dendrimers surface characteristics installed conventionally or with Piezosurgery®. A comparative study in the dog

被引:29
作者
Bengazi, Franco [1 ]
Lang, Niklaus P. [2 ]
Canciani, Elena [3 ]
Vigano, Paolo [1 ]
Velez, Joaquin Urbizo [1 ]
Botticelli, Daniele [2 ,4 ,5 ]
机构
[1] Univ Med Sci, Fac Dent, Havana, Cuba
[2] Univ Hong Kong, Prince Philip Dent Hosp, Hong Kong, Hong Kong, Peoples R China
[3] Univ Milan, Dipartimento Sci Biomed Salute, Milan, Italy
[4] Univ Estadual Paulista, Fac Odontol Aracatuba, Sao Paulo, Brazil
[5] ARDEC, Ariminum Odontol, Rimini, Italy
关键词
animal study; bone healing; dendrimers coating; histology; implant dentistry; osseointegration; Piezosurgery((R)); surface characteristics; DENTAL IMPLANTS; CORTICAL BONE; IRRIGATION; TEMPERATURE; SURGERY;
D O I
10.1111/clr.12082
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimThe first aim of the present experiment was to compare bone healing at implants installed in recipient sites prepared with conventional drills or a piezoelectric device. The second aim was to compare implant osseointegration onto surfaces with and without dendrimers coatings. Material and MethodsSix Beagles dogs were used in this study. Five implants with two different surfaces, three with a ZirTi((R)) surface (zirconia sand blasted, acid etched), and two with a ZirTi((R))-modified surface with dendrimers of phosphoserine and polylysine were installed in the right side of the mandible. In the most anterior region (P2, P3), two recipient sites were prepared with drills, and one implant ZirTi((R)) surface and one coated with dendrimers implants were installed at random. In the posterior region (P4 and M1), three recipient sites were randomly prepared: two sites with a Piezosurgery((R)) instrument and one site with drill and two ZirTi((R)) surface and one coated with dendrimers implants installed. Three months after the surgery, the animals were sacrificed for histological analysis. ResultsNo complications occurred during the healing period. Three implants were found not integrated and were excluded from analysis. However, n=6 was obtained. The distance IS-B at the buccal aspect was 2.20.8 and 1.8 +/- 0.5mm, while IS-C was 1.5 +/- 0.9 and 1.4 +/- 0.6mm at the Piezosurgery((R)) and drill groups, respectively. Similar values were obtained between the dendrimers-coated and ZirTi((R)) surface implants. The BIC% values were higher at the drill (72%) compared to the Piezosurgery((R)) (67%) sites. The BIC% were also found to be higher at the ZirTi((R)) (74%) compared to the dendrimers-coated (65%) implants, the difference being statistically significant. ConclusionThis study has revealed that oral implants may osseointegrate equally well irrespective of whether their bed was prepared utilizing conventional drills with abundant cooling or Piezosurgery((R)). Moreover, the surface coating of implants with dendrimers phosphoserine and polylysine did not improve osseointegration.
引用
收藏
页码:10 / 15
页数:6
相关论文
共 21 条
[1]   Thermal changes observed at implant sites during internal and external irrigation [J].
Benington, IC ;
Biagioni, PA ;
Briggs, J ;
Sheridan, S ;
Lamey, PJ .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) :293-297
[2]   Bone healing at implants with a fluoride-modified surface: an experimental study in dogs [J].
Berglundh, T. ;
Abrahamsson, I. ;
Albouy, J. -P. ;
Lindhe, J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (02) :147-152
[3]  
COSTICH EMMETT R., 1964, ORAL SURG ORAL MED ORAL PATHOL, V17, P563, DOI 10.1016/0030-4220(64)90359-7
[4]  
Di Alberti L, 2010, QUINTESSENCE INT, V41, P639
[5]  
Ercoli C, 2004, INT J ORAL MAX IMPL, V19, P335
[6]   HEAT CAUSED BY DRILLING CORTICAL BONE - TEMPERATURE MEASURED INVIVO IN PATIENTS AND ANIMALS [J].
ERIKSSON, AR ;
ALBREKTSSON, T ;
ALBREKTSSON, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06) :629-631
[7]  
Eriksson R.A., 1983, J PROSTHET DENT, V50, P101
[8]  
Galli C, 2010, CLIN ORAL IMPLAN RES, V21, P1172
[9]   Factors influencing resonance frequency analysis assessed by Osstell™ mentor during implant tissue integration: II. Implant surface modifications and implant diameter [J].
Han, Jie ;
Lulic, Martina ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (06) :605-611
[10]   Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans [J].
Lang, Niklaus P. ;
Salvi, Giovanni E. ;
Huynh-Ba, Guy ;
Ivanovski, Saso ;
Donos, Nikolaos ;
Bosshardt, Dieter D. .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (04) :349-356