Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels

被引:13
作者
Bacchi, Atais [1 ]
Paludo, Litiane [2 ]
Mesquita, Marcelo Ferraz [1 ]
Schuh, Christian [2 ]
Federizzi, Leonardo [2 ]
Spazzin, Aloisio Oro [2 ]
机构
[1] State Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Prosthodont & Periodont, Piracicaba, SP, Brazil
[2] Merid Fac, Merid Ctr Dent Studies CEOM, Dept Prosthodont, Passo Fundo, RS, Brazil
关键词
Denture; Implant-supported dental prosthesis; Fit; OSSEOINTEGRATED IMPLANTS; STRESS-DISTRIBUTION; FIXED PROSTHESES; DENTAL IMPLANTS; FIT; DENTISTRY; 15-YEAR; MAXILLA; TIME; BAR;
D O I
10.1016/j.jbiomech.2013.01.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this study was to evaluate the effect of the prosthesis material (metal-acrylic resin or metal-ceramic) on loosening torque of the prosthetic screws in an implant-supported mandibular denture under two levels of vertical misfit. Ten frameworks were fabricated with commercially pure titanium, and five of them received acrylic resin and acrylic artificial teeth as veneering material and the other five were veneered with porcelain. Two levels of vertical fit were also created by fabricating 20 cast models to obtain four experimental groups according to the prosthesis material and misfit: Group 1 (metal-acrylic resin prosthesis with a passive fit); Group 2 (metal-acrylic resin prosthesis with a non-passive fit); Group 3 (metal-ceramic prosthesis with a passive fit); and Group 4 (metal-ceramic prosthesis with a non-passive fit). Two hundred prosthetic titanium-alloy screws were divided in 40 sets (five screws per set, n=10). After 24 h, the loosening torque of the screws was evaluated using a digital torque meter. The results were submitted to two-way ANOVA analysis of variance followed by a Tukey's test (alpha = 0.05). The mean values and standard deviations for each group were G1=7.05 (1.64), G2=5.52 (0.90), G3=6.46 (1.34), and G4=4.35 (0.99). Overall, the prosthesis material and misfit factors showed a statistically significant influence on the loosening torque (p < 0.05). Metal-ceramic prosthesis and misfits decreased the loosening of the torque of the prosthetic screws. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1358 / 1362
页数:5
相关论文
共 38 条
[1]   Influence of Material of Overdenture-Retaining Bar with Vertical Misfit on Three-Dimensional Stress Distribution [J].
Abreu, Ricardo T. ;
Spazzin, Aloisio O. ;
Noritomi, Pedro Y. ;
Consani, Rafael Leonardo X. ;
Mesquita, Marcelo F. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (06) :425-431
[2]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[3]  
Al-Turki LEE, 2002, INT J PROSTHODONT, V15, P38
[4]   Influence of occlusal forces on stress distribution in preloaded dental implant screws [J].
Alkan, I ;
Sertgöz, A ;
Ekici, E .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04) :319-325
[5]  
Bauman G R, 1992, Int J Oral Maxillofac Implants, V7, P330
[6]   Complication rate with prosthodontic reconstructions on ITI and IMZ dental implants [J].
Behr, M ;
Lang, R ;
Leibrock, A ;
Rosentritt, M ;
Handel, G .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (01) :51-58
[7]   A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years [J].
Berglundh, T ;
Persson, L ;
Klinge, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 :197-212
[8]  
Bickford J.H., 2007, INTRO DESIGN BEHAV B, VFourth
[9]  
Cantwell A, 2004, INT J ORAL MAX IMPL, V19, P124
[10]  
Carlson B, 1994, Int J Oral Maxillofac Implants, V9, P90