Use of Tracer Kinetic Models for Selection of Semi-Quantitative Features for DCE-MRI Data Classification

被引:26
作者
Fusco, R. [1 ]
Petrillo, A. [1 ]
Petrillo, M. [1 ]
Sansone, M. [2 ]
机构
[1] Ist Nazl Tumori Fdn G Pascale IRCCS, Dept Diagnost Imaging Radiant & Metab Therapy, Div Radiol, Naples, Italy
[2] Univ Naples Federico II, Dept Elect Engn & Informat Technol, Naples, Italy
关键词
TISSUE HOMOGENEITY MODEL; CONTRAST-ENHANCED MRI; PHARMACOKINETIC PARAMETERS; LESION CLASSIFICATION; VASCULAR-PERMEABILITY; TEXTURE ANALYSIS; BREAST; DIAGNOSIS; EXCHANGE; DENSITY;
D O I
10.1007/s00723-013-0481-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The aim of this study was to identify, on the basis of simulated tracer kinetic data, the best subset of semi-quantitative features suitable for classification of dynamic contrast-enhanced magnetic resonance imaging data. 1926 time concentration curves (TCCs) of Type III, IV and V [according to the classification of Daniel et al. (Radiology 209(2): 499-509 (1998))] were simulated using the gamma capillary transit time model and the Parker's arterial input function. TCCs were converted in time intensity curves (TICs) corresponding to a gradient echo sequence. Seventeen semi-quantitative shape descriptors were extracted from each TIC. Feature selection in combination with classification and regression tree was adopted. Several acquisition parameters (total duration, time resolution, noise level) were used to simulate TICs to evaluate the influence on the features selected and on the overall accuracy. The highest accuracy (99.8 %) was obtained using 5 features, total duration 9 min and time resolution 60 s. However, an accuracy of 93.5 % was achieved using only 3 features, total duration 6 min and time resolution 60 s. This latter configuration has the advantage of requiring the smallest number of features (easily understandable by the radiologist) and not a very long duration (reduced patient discomfort).
引用
收藏
页码:1311 / 1324
页数:14
相关论文
共 50 条
[1]   The precision of pharmacokinetic parameters in dynamic contrast-enhanced magnetic resonance imaging: the effect of sampling frequency and duration [J].
Aerts, Hugo J. W. L. ;
Jaspers, K. ;
Backes, Walter H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17) :5665-5678
[2]  
[Anonymous], 1998, CORRELATION BASED FE
[3]  
[Anonymous], 1984, OLSHEN STONE CLASSIF, DOI 10.2307/2530946
[4]  
[Anonymous], 2012, J BIOMEDICAL GRAPHIC
[5]   Breast MRI lesion classification: Improved performance of human readers with a backpropagation neural network computer-aided diagnosis (CAD) system [J].
Arbash Meinel, Lina ;
Stolpen, Alan H. ;
Berbaum, Kevin S. ;
Fajardo, Laurie L. ;
Reinhardt, Joseph M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) :89-95
[6]   The pelvis after surgery and radio-chemotherapy for rectal cancer studied with Gd-DTPA-enhanced fast dynamic MR imaging [J].
Blomqvist, L ;
Fransson, P ;
Hindmarsh, T .
EUROPEAN RADIOLOGY, 1998, 8 (05) :781-787
[7]   PHARMACOKINETIC PARAMETERS IN CNS GD-DTPA ENHANCED MR IMAGING [J].
BRIX, G ;
SEMMLER, W ;
PORT, R ;
SCHAD, LR ;
LAYER, G ;
LORENZ, WJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :621-628
[8]   Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI [J].
Buckley, DL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :601-606
[9]   Breast disease: Dynamic spiral MR imaging [J].
Daniel, BL ;
Yen, YF ;
Glover, GH ;
Ikeda, DM ;
Birdwell, RL ;
Sawyer-Glover, AM ;
Black, JW ;
Plevritis, SK ;
Jeffrey, SS ;
Herfkens, RJ .
RADIOLOGY, 1998, 209 (02) :499-509
[10]   Mapping pathophysiological features of breast tumors by MRI at high spatial resolution [J].
Degani, H ;
Gusis, V ;
Weinstein, D ;
Fields, S ;
Strano, S .
NATURE MEDICINE, 1997, 3 (07) :780-782