Protection against ionizing radiation by leaded glass googles during interventional cardiology

被引:4
|
作者
Zett-Lobos, Claudio [1 ]
Vera-Munoz, Felipe [5 ]
Arriola-Alvarez, Katerina
Diaz-Ramos, Oscar [5 ]
Gamarra, Jorge [4 ]
Fernandez-Palomo, Cristian [6 ]
Merello, Lorenzo [3 ]
Mora, Alex D.
Gutierrez, Alejandro [2 ]
Catalan-Reyes, Monica [7 ]
Ramos-Avasola, Sergio [2 ]
机构
[1] Pontificia Univ Catolica Valparaiso, Fac Ciencias, Valparaiso, Chile
[2] Univ Santo Tomas, Fac Salud, Escuela Tecnol Med, Santiago, Chile
[3] Univ Valparaiso, Fac Med, Escuela Med, Valparaiso, Chile
[4] Comis Chilena Energia Nucl, Dept Dosimetria, Santiago, Chile
[5] Clin Renaca SA, Vina Del Mar, Chile
[6] McMaster Univ, Med Phys & Appl Radiat Sci Dept, Hamilton, ON L8S 4L8, Canada
[7] Univ Valparaiso, Fac Ciencias, Dept Estadist, Valparaiso, Chile
关键词
Lens; Crystalline; Radiation dosage; Radiology; Interventional; EXPOSURE; CATARACT; LENS; RISK; EYES;
D O I
10.4067/S0034-98872013000100009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Protection against ionizing radiation by leaded glass googles during interventional cardiology Background: It is not known whether leaded glass goggles with 0.25 mm Pb equivalency, used in interventional cardiology procedures, attenuate radiation below the levels established by the latest recommendation of the International Commission on Radiological Protection (ICRP). Aim: To assess if the degree of attenuation of the secondary ionizing radiation achieved by the use of 0.25 mm Pb leaded glass goggles, in occupationally exposed workers in interventional cardiology procedures, meets the latest ICRP recommendations. Material and Methods: A prospective investigation was carried out to compare the eye exposure to secondary ionizing radiation received by occupationally exposed personnel in a 9 months period. A set of two thermo luminescent dosimeters was arranged in the front and back of leaded glass goggles in a cohort of seven members of an interventional cardiology service, exposed to 1057 consecutive procedures. Results: The monthly dose equivalent measurement performed in front of the goggles ranged between 1.1 and 6.5 mSv, for paramedics and interventional cardiologists. The radiation measured in the back of the glass varied between 0.66 and 2.75 mSv, respectively. The degree of attenuation of the dose at eye level ranged from 40% to 57.7%, respectively. The projected annual exposure would reach 33 mSv for the interventional cardiologist. Conclusions: With a similar load of work and wearing 0.25 mm Pb equivalent glass goggles, interventional cardiologists will exceed the crystalline equivalent dose limit recommended by the ICRP (20 mSv/year averaged over the past 5 years). (Rev Med Chile 2013; 141: 63-69).
引用
收藏
页码:63 / 69
页数:7
相关论文
共 18 条
  • [1] Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania
    Valuckiene, Zivile
    Jurenas, Martynas
    Cibulskaite, Inga
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (03) : 695 - 708
  • [2] Recommendations for occupational radiation protection in interventional cardiology
    Duran, Ariel
    Hian, Sim Kui
    Miller, Donald L.
    Le Heron, John
    Padovani, Renato
    Vano, Eliseo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (01) : 29 - 42
  • [3] Radiation protection provided by tungsten bismuth caps during interventional cardiology
    Ramos-Avasola, Sergio
    Diaz, Natalia
    Roldan, Reynaldo
    Gamarra, Jorge
    Catalan, Monica
    REVISTA MEDICA DE CHILE, 2016, 144 (07) : 837 - 843
  • [4] Radiation protection and arterial route in interventional cardiology
    Georges, J. -L.
    Gibault-Genty, G.
    Charbonnel, C.
    Aziza, J. -P.
    Fetoui, A.
    Pessenti-Rossi, D.
    Livarek, B.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2009, 58 (06): : 366 - 372
  • [5] Effectiveness of staff radiation protection devices for interventional cardiology procedures
    Huet, Christelle
    Dabin, Jeremie
    Domienik-Andrzejewska, Joanna
    Hebre, Alexandre
    da Silva, Edilaine Honorio
    Lombardo, Pasquale
    Tamborino, Giulia
    Vanhavere, Filip
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 107
  • [6] Radiation Protection in Interventional Radiology/Cardiology-Is State-of-the-Art Equipment Used?
    Behr-Meenen, Christiane
    von Boetticher, Heiner
    Kersten, Jan Felix
    Nienhaus, Albert
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (24)
  • [7] Occupational radiation dose and protection to the eye lens for interventional cardiology operators
    Lian, Meng-En
    Wu, Guan-Yi
    Chao, Min-Fang
    Wang, Chong-Sheng
    Miao, Hsiao-Chien
    Tsai, Ming-Sung
    Hsieh, Mu-Yang
    Chen, Yeh-Peng
    Chu, Chun-Yuan
    Chang, Szu-Li
    Tsai, Hui-Yu
    RADIATION MEASUREMENTS, 2022, 154
  • [8] A summary of recommendations for occupational radiation protection in interventional cardiology
    Duran, Ariel
    Hian, Sim Kui
    Miller, Donald L.
    Le Heron, John
    Padovani, Renato
    Vano, Eliseo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 562 - 567
  • [9] A report on a survey among Portuguese Association of Interventional Cardiology associates regarding ionizing radiation protection practices in national interventional cath-labs
    Costa, Hugo
    Vinhas, Hugo
    Cale, Rita
    Pereira, Ernesto
    Santos, Joana
    Paulo, Graciano
    Jorge, Elisabete
    Brochado, Bruno
    Melica, Bruno
    Goncalves, Rui Baptista
    de Oliveira, Eduardo Infante
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2024, 43 (04) : 177 - 185
  • [10] Radiation Dose and Radiation Protection for Patients and Physicians During Interventional Procedure
    Chida, Koichi
    Kato, Mamoru
    Kagaya, Yutaka
    Zuguchi, Masayuki
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Yamada, Shogo
    Takai, Yoshihiro
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 97 - 105