Targeted and Reversible Blood-Retinal Barrier Disruption via Focused Ultrasound and Microbubbles

被引:31
|
作者
Park, Juyoung [1 ,2 ]
Zhang, Yongzhi [1 ,2 ]
Vykhodtseva, Natalia [1 ,2 ]
Akula, James D. [2 ,3 ]
McDannold, Nathan J. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Childrens Hosp, Dept Ophthalmol, Boston, MA 02115 USA
来源
PLOS ONE | 2012年 / 7卷 / 08期
基金
美国国家卫生研究院;
关键词
BRAIN-BARRIER; DRUG-DELIVERY; THERAPEUTIC ULTRASOUND; CONTRAST AGENT; INTRAOCULAR-PRESSURE; ENDOTHELIAL-CELLS; INDUCED LESIONS; REAL-TIME; GLAUCOMA; EYE;
D O I
10.1371/journal.pone.0042754
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The blood-retinal barrier (BRB) prevents most systemically-administered drugs from reaching the retina. This study investigated whether burst ultrasound applied with a circulating microbubble agent can disrupt the BRB, providing a noninvasive method for the targeted delivery of systemically administered drugs to the retina. To demonstrate the efficacy and reversibility of such a procedure, five overlapping targets around the optic nerve head were sonicated through the cornea and lens in 20 healthy male Sprague-Dawley rats using a 690 kHz focused ultrasound transducer. For BRB disruption, 10 ms bursts were applied at 1 Hz for 60 s with different peak rarefactional pressure amplitudes (0.81, 0.88 and 1.1 MPa). Each sonication was combined with an IV injection of a microbubble ultrasound contrast agent (Definity). To evaluate BRB disruption, an MRI contrast agent (Magnevist) was injected IV immediately after the last sonication, and serial T1-weighted MR images were acquired up to 30 minutes. MRI contrast enhancement into the vitreous humor near targeted area was observed for all tested pressure amplitudes, with more signal enhancement evident at the highest pressure amplitude. At 0.81 MPa, BRB disruption was not detected 3 h post sonication, after an additional MRI contrast injection. A day after sonication, the eyes were processed for histology of the retina. At the two lower exposure levels (0.81 and 0.88 MPa), most of the sonicated regions were indistinguishable from the control eyes, although a few tiny clusters of extravasated erythrocytes (petechaie) were observed. More severe retinal damage was observed at 1.1 MPa. These results demonstrate that focused ultrasound and microbubbles can offer a noninvasive and targeted means to transiently disrupt the BRB for ocular drug delivery.
引用
收藏
页数:8
相关论文
共 50 条