Targeted and Reversible Blood-Retinal Barrier Disruption via Focused Ultrasound and Microbubbles

被引:33
作者
Park, Juyoung [1 ,2 ]
Zhang, Yongzhi [1 ,2 ]
Vykhodtseva, Natalia [1 ,2 ]
Akula, James D. [2 ,3 ]
McDannold, Nathan J. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Childrens Hosp, Dept Ophthalmol, Boston, MA 02115 USA
来源
PLOS ONE | 2012年 / 7卷 / 08期
基金
美国国家卫生研究院;
关键词
BRAIN-BARRIER; DRUG-DELIVERY; THERAPEUTIC ULTRASOUND; CONTRAST AGENT; INTRAOCULAR-PRESSURE; ENDOTHELIAL-CELLS; INDUCED LESIONS; REAL-TIME; GLAUCOMA; EYE;
D O I
10.1371/journal.pone.0042754
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The blood-retinal barrier (BRB) prevents most systemically-administered drugs from reaching the retina. This study investigated whether burst ultrasound applied with a circulating microbubble agent can disrupt the BRB, providing a noninvasive method for the targeted delivery of systemically administered drugs to the retina. To demonstrate the efficacy and reversibility of such a procedure, five overlapping targets around the optic nerve head were sonicated through the cornea and lens in 20 healthy male Sprague-Dawley rats using a 690 kHz focused ultrasound transducer. For BRB disruption, 10 ms bursts were applied at 1 Hz for 60 s with different peak rarefactional pressure amplitudes (0.81, 0.88 and 1.1 MPa). Each sonication was combined with an IV injection of a microbubble ultrasound contrast agent (Definity). To evaluate BRB disruption, an MRI contrast agent (Magnevist) was injected IV immediately after the last sonication, and serial T1-weighted MR images were acquired up to 30 minutes. MRI contrast enhancement into the vitreous humor near targeted area was observed for all tested pressure amplitudes, with more signal enhancement evident at the highest pressure amplitude. At 0.81 MPa, BRB disruption was not detected 3 h post sonication, after an additional MRI contrast injection. A day after sonication, the eyes were processed for histology of the retina. At the two lower exposure levels (0.81 and 0.88 MPa), most of the sonicated regions were indistinguishable from the control eyes, although a few tiny clusters of extravasated erythrocytes (petechaie) were observed. More severe retinal damage was observed at 1.1 MPa. These results demonstrate that focused ultrasound and microbubbles can offer a noninvasive and targeted means to transiently disrupt the BRB for ocular drug delivery.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Blood-Brain Barrier Opening in Behaving Non-Human Primates via Focused Ultrasound with Systemically Administered Microbubbles
    Downs, Matthew E.
    Buch, Amanda
    Karakatsani, Maria Eleni
    Konofagou, Elisa E.
    Ferrera, Vincent P.
    SCIENTIFIC REPORTS, 2015, 5
  • [22] The kinetics of blood brain barrier permeability and targeted doxorubicin delivery into brain induced by focused ultrasound
    Park, Juyoung
    Zhang, Yongzhi
    Vykhodtseva, Natalia
    Jolesz, Ferenc A.
    McDannold, Nathan J.
    JOURNAL OF CONTROLLED RELEASE, 2012, 162 (01) : 134 - 142
  • [23] Gradual Suppression of Transcytosis Governs Functional Blood-Retinal Barrier Formation
    Chow, Brian Wai
    Gu, Chenghua
    NEURON, 2017, 93 (06) : 1325 - +
  • [24] The inner blood-retinal barrier: Cellular basis and development
    Diaz-Coranguez, Monica
    Ramos, Carla
    Antonetti, David A.
    VISION RESEARCH, 2017, 139 : 123 - 137
  • [25] Targeted shRNA-loaded liposome complex combined with focused ultrasound for blood brain barrier disruption and suppressing glioma growth
    Zhao, Guanjian
    Huang, Qin
    Wang, Feng
    Zhang, Xiang
    Hu, Jiangang
    Tan, Ying
    Huang, Ning
    Wang, Zhigang
    Wang, Zhibiao
    Cheng, Yuan
    CANCER LETTERS, 2018, 418 : 147 - 158
  • [26] Ocular Manifestations of Emerging Flaviviruses and the Blood-Retinal Barrier
    Singh, Sneha
    Kumar, Ashok
    VIRUSES-BASEL, 2018, 10 (10):
  • [27] Inner Blood-Retinal Barrier Transporters: Role of Retinal Drug Delivery
    Hosoya, Ken-ichi
    Tachikawa, Masanori
    PHARMACEUTICAL RESEARCH, 2009, 26 (09) : 2055 - 2065
  • [28] Current clinical investigations of focused ultrasound blood-brain barrier disruption: A review
    Durham, Phillip G.
    Butnariu, Alexandra
    Alghorazi, Rizk
    Pinton, Gianmarco
    Krishna, Vibhor
    Dayton, Paul A.
    NEUROTHERAPEUTICS, 2024, 21 (03)
  • [29] SAFETY VALIDATION OF REPEATED BLOOD-BRAIN BARRIER DISRUPTION USING FOCUSED ULTRASOUND
    Kobus, Thiele
    Vykhodtseva, Natalia
    Pilatou, Magdalini
    Zhang, Yongzhi
    McDannold, Nathan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02) : 481 - 492
  • [30] The new insight into the inflammatory response following focused ultrasound-mediated blood-brain barrier disruption
    Choi, Hyo Jin
    Han, Mun
    Seo, Hyeon
    Park, Chan Yuk
    Lee, Eun-Hee
    Park, Juyoung
    FLUIDS AND BARRIERS OF THE CNS, 2022, 19 (01)