Evaluation of MR imaging with T1 and T2*mapping for the determination of hepatic iron overload

被引:72
作者
Henninger, B. [1 ]
Kremser, C. [1 ]
Rauch, S. [1 ]
Eder, R. [1 ]
Zoller, H. [2 ]
Finkenstedt, A. [2 ]
Michaely, H. J. [3 ]
Schocke, M. [1 ]
机构
[1] Innsbruck Med Univ, Dept Radiol, A-6020 Innsbruck, Austria
[2] Innsbruck Med Univ, Dept Internal Med, A-6020 Innsbruck, Austria
[3] Heidelberg Univ, Inst Clin Radiol & Nucl Med, Univ Med Ctr Mannheim, Med Fac Mannheim, D-6800 Mannheim, Germany
关键词
Magnetic resonance imaging; MRI; Liver; Fatty liver; Hemochromatosis; Hepatic iron; Iron overload; T2*; T1; MAGNETIC-RESONANCE; LIVER IRON; QUANTIFICATION; HEMOCHROMATOSIS; DIAGNOSIS; DEPOSITION; VARIABILITY; THALASSEMIA; CIRRHOSIS; SEQUENCE;
D O I
10.1007/s00330-012-2506-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate MRI using T1 and T2* mapping sequences in patients with suspected hepatic iron overload (HIO). Twenty-five consecutive patients with clinically suspected HIO were retrospectively studied. All underwent MRI and liver biopsy. For the quantification of liver T2* values we used a fat-saturated multi-echo gradient echo sequence with 12 echoes (TR = 200 ms, TE = 0.99 ms + n x 1.41 ms, flip angle 20A degrees). T1 values were obtained using a fast T1 mapping sequence based on an inversion recovery snapshot FLASH sequence. Parameter maps were analysed using regions of interest. ROC analysis calculated cut-off points at 10.07 ms and 15.47 ms for T2* in the determination of HIO with accuracy 88 %/88 %, sensitivity 84 %/89.5 % and specificity 100 %/83 %. MRI correctly classified 20 patients (80 %). All patients with HIO only had decreased T1 and T2* relaxation times. There was a significant difference in T1 between patients with HIO only and patients with HIO and steatohepatitis (P = 0.018). MRI-based T2* relaxation diagnoses HIO very accurately, even at low iron concentrations. Important additional information may be obtained by the combination of T1 and T2* mapping. It is a rapid, non-invasive, accurate and reproducible technique for validating the evidence of even low hepatic iron concentrations. aEuro cent Hepatic iron overload causes fibrosis, cirrhosis and increases hepatocellular carcinoma risk. aEuro cent MRI detects iron because of the field heterogeneity generated by haemosiderin. aEuro cent T2* relaxation is very accurate in diagnosing hepatic iron overload. aEuro cent Additional information may be obtained by T1 and T2* mapping.
引用
收藏
页码:2478 / 2486
页数:9
相关论文
共 36 条
[1]  
Adams PC, 2001, AM J GASTROENTEROL, V96, P567
[2]   MR quantification of hepatic iron concentration [J].
Alústiza, JM ;
Artetxe, J ;
Castiella, A ;
Agirre, C ;
Emparanza, JI ;
Otazua, P ;
García-Bengoechea, M ;
Barrio, J ;
Mújica, F ;
Recondo, JA .
RADIOLOGY, 2004, 230 (02) :479-484
[3]   Iron overload in the liver diagnostic and quantification [J].
Alustiza, Jose M. ;
Castiella, Agustin ;
De Juan, Maria D. ;
Emparanza, Jose I. ;
Artetxe, Jose ;
Uranga, Maite .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (03) :499-506
[4]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[5]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[6]   Hepatic iron concentration: Noninvasive estimation by means of MR imaging techniques [J].
Bonkovsky, HL ;
Rubin, RB ;
Cable, EE ;
Davidoff, A ;
Rijcken, THP ;
Stark, DD .
RADIOLOGY, 1999, 212 (01) :227-234
[7]   Liver iron concentration quantification by MRI: are recommended protocols accurate enough for clinical practice? [J].
Castiella, Agustin ;
Alustiza, Jose M. ;
Emparanza, Jose I. ;
Ma Zapata, Eva ;
Costero, Belen ;
Diez, Maria I. .
EUROPEAN RADIOLOGY, 2011, 21 (01) :137-141
[8]   In vivo magnetic resonance (MR) study of fatty liver: Importance of intracellular ultrastructural alteration for MR tissue parameters change [J].
Chai, JW ;
Lin, YC ;
Chen, JH ;
Wu, CC ;
Lee, CP ;
Chu, WC ;
Lee, SK .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (01) :35-41
[9]   Hepatic Iron Deposition in Patients With Liver Disease: Preliminary Experience With Breath-Hold Multiecho T2*-Weighted Sequence [J].
Chandarana, Hersh ;
Lim, Ruth P. ;
Jensen, Jens H. ;
Hajdu, Cristina H. ;
Losada, Mariela ;
Babb, James S. ;
Huffman, Steve ;
Taouli, Bachir .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) :1261-1267
[10]   What can we expect from non invasive imaging methods to detect and grade liver fatty infiltration? [J].
Chevallier, P .
GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2005, 29 (11) :1133-1135