Planar 123I-MIBG heart-to-mediastinum ratio: the impact of a predefined ROI and collimator type on reproducibility

被引:0
作者
Verschure, D. O. [1 ,2 ]
Bongers, V. [3 ]
Hagen, P. J. [3 ]
van Ofwegen-Hanekamp, C. E. E. [3 ]
Somsen, G. A. [2 ,4 ]
van Eck-Smit, B. L. F. [1 ]
Verberne, H. J. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, NL-1105 AZ Amsterdam, Netherlands
[2] Onze Lieve Vrouw Hosp, Amsterdam, Netherlands
[3] Diakonessen Hosp, Utrecht, Netherlands
[4] Cardiol Ctr Netherlands, Amsterdam, Netherlands
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:S439 / S440
页数:2
相关论文
共 50 条
  • [31] Influence of collimator choice and simulated clinical conditions on 123I-MIBG heart/mediastinum ratios:: a phantom study
    Verberne, HJ
    Feenstra, C
    de Jong, WM
    Somsen, GA
    van Eck-Smit, BLF
    Sokole, EB
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (09) : 1100 - 1107
  • [32] Effect of gamma camera design on the heart-to-mediastinum ratio from simulated planar [123I]mIBG images of a thorax phantom
    Owenius, Rikard
    Zanette, Michelle
    Weick, Sharon
    Cella, Patrick
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [33] Effect of gamma camera design on the heart-to-mediastinum ratio from simulated planar [123I]mIBG images of a thorax phantom
    Owenius, Rikard
    Zanette, Michelle
    Weick, Sharon
    Cella, Patrick
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [34] The Effect of Type of Collimation, Duration of Image Acquisition and Scatter Correction in Heart-to-Mediastinum Ratio of I-123-MIBG Scintigraphy
    Chaves, S.
    Vieira, T.
    Pinto, A. Sa
    Alves, V.
    Fernandes, A.
    Pereira, J. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S169 - S169
  • [35] Quantification of Heart-to-Mediastinum Ratio of I-123-MIBG Scintigraphy in a Cardiac Phantom: influence of collimator choice and of diverse energy window for scatter correction
    Chaves, S.
    Faria, A.
    Vieira, T.
    Pereira, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S660 - S661
  • [36] How critical is definition of myocardial region of interest for determination of heart-mediastinum ratio on planar 123I-mIBG myocardial imaging?
    Jacobson, Arnold
    Matsuoka, Dale
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [37] COMPARABILITY OF HEART-TO-MEDIASTINUM RATIO DETERMINATION FROM I-123 MIBG SPECT AND PLANAR IMAGING: NEW ANALYSES FROM ADMIRE-HF
    Chen, Ji
    Folks, Russell D.
    Verdes-Moreiras, Liudmila
    Manatunga, Daya N.
    Jacobson, Arnold F.
    Garcia, Ernest V.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E690 - E690
  • [38] 123I-MIBG Cardiac Scintigraphy and Heart/Mediastinum Ratio in Neurodegenerative Disorders: Is Delayed Scan Really Necessary?
    Nuvoli, Susanna
    Palumbo, Barbara
    Marongiu, Andrea
    Bianconi, Francesco
    Spanu, Angela
    CURRENT RADIOPHARMACEUTICALS, 2022, 15 (04) : 257 - 258
  • [39] Effect of standardization of I-123 MIBG heart-to-mediastinum ratio on the prognostic threshold: application to multicenter database of chronic heart failure
    Nakajima, K.
    Okuda, K.
    Matsuo, S.
    Nakata, T.
    Kinuya, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S28 - S28
  • [40] Semi-automated measurements of heart-to-mediastinum ratio on 123I-MIBG myocardial Scintigrams by using image fusion method with chest X-ray images
    Kawai, Ryosuke
    Hara, Takeshi
    Katafuchi, Tetsuro
    Ishihara, Tadahiko
    Zhou, Xiangrong
    Muramatsu, Chisako
    Abe, Yoshiteru
    Fujita, Hiroshi
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414