An observational study of post-operative volumetric modulated arc radiotherapy (VMAT) of breast cancer by immobilizing patients on All-in-One (AIO™) solution breast and lung board without using thermoplastic mask: risk of collision of gantry with couch exists if acquisition of Cone Beam Computed Tomography (CBCT) is attempted for set-up verification

被引:0
作者
Kumar, Ramaiah Vinay [1 ]
机构
[1] Kidwai Mem Inst Oncol, Radiat Oncol, MH Marigowda Rd, Bangalore 560029, Karnataka, India
关键词
Breast cancer; Volumetric modulated arc therapy (VMAT); All-in-One (AIO (TM)) solution breast and lung board; Cone beam computed tomography (CBCT); THERAPY;
D O I
10.1007/s13566-020-00434-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Automatic cone beam computed tomography (CBCT)-based image matching for set-up verification is recommended as compared with 2D image match for post-operative local/loco-regional radiotherapy of breast cancer patients by volumetric modulated arc therapy (VMAT) technique. However, in a supine position, off-midline peripheral body clinical target volume (CTV) of unilateral breast cancer patients immobilized on breast and lung board of All-in-One (AIO) positioning system may necessitate augmented movement of the couch in 'x' and 'z' axes thereby raising the risk of collision of x-ray sources/detector system with couch. Methods and material VMAT was planned by a pair of partial arcs for the whole target volume for seven consecutive post-operative breast cancer patients (five post-mastectomy and two post-breast conservation patients). Tattoo-based set-up by the shift of treatment table inx-,y-, andz-axis as determined by treatment planning system followed by x-rays with planar image acquisition and online 2D image matching with Digitally reconstructed radiographs (DRRs) was performed for set-up verification. In-room 360 degrees rotation of x-ray source and detector system of a linear accelerator (linac) was performed before x-ray planar image acquisition. Result Completion of 360 degrees in-room rotation of x-ray source and detector system of linac around the machine isocentre was not possible in six out of seven patients due to the possibility of collision of the gantry with contralateral side of the couch. Conclusion Performing CBCT for generating 3D images for computed tomography (CT) reconstruction may not be practical for patient set-up verification of post-operative radiotherapy of unilateral breast cancer patients positioned supine on breast and lung board.
引用
收藏
页码:155 / 163
页数:9
相关论文
共 8 条
[1]   Potential benefits of crawl position for prone radiation therapy in breast cancer [J].
Boute, Bert ;
De Neve, Wilfried ;
Speleers, Bruno ;
Van Greveling, Annick ;
Monten, Christel ;
Van Hoof, Tom ;
Van de Velde, Joris ;
Paelinck, Leen ;
De Gersem, Werner ;
Vercauteren, Tom ;
Detand, Jan ;
Veldeman, Liv .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04) :200-205
[2]   Radiotherapy-induced secondary cancer risk for breast cancer: 3D conformal therapy versus IMRT versus VMAT [J].
Lee, Boram ;
Lee, Sunyoung ;
Sung, Jiwon ;
Yoon, Myonggeun .
JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (02) :325-331
[3]   VMAT techniques for lymph node-positive left sided breast cancer [J].
Pasler, Marlies ;
Lutterbach, Johannes ;
Bjoernsgard, Mari ;
Reichmann, Ursula ;
Bartelt, Susanne ;
Georg, Dietmar .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (02) :104-111
[4]   Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy [J].
Qi, X. Sharon ;
Liu, Tian X. ;
Liu, Arthur K. ;
Newman, Francis ;
Rabinovitch, Rachel ;
Kavanagh, Brian ;
Hu, Y. Angie .
MEDICAL DOSIMETRY, 2014, 39 (03) :227-234
[5]  
rifit-The precision expert. Press Information, 2019, ORFIT IND RECEIVED F
[6]   Dosimetric effects of anatomical deformations and positioning errors in VMAT breast radiotherapy [J].
Rossi, Maija ;
Boman, Eeva ;
Skytta, Tanja ;
Haltamo, Mikko ;
Laaksomaa, Marko ;
Kapanen, Mika .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05) :506-516
[7]   Advantages of a technique using two 50 degree arcs in simultaneous integrated boost radiotherapy for left-sidebreast cancer [J].
Xi, Dan ;
Ding, Yun ;
Hu, Rui ;
Gu, Wendong ;
Mu, Jinming ;
Li, Qilin .
SCIENTIFIC REPORTS, 2017, 7
[8]   Tangent-based volumetric modulated arc therapy for advanced left breast cancer [J].
Yu, Pei-Chieh ;
Wu, Ching-Jung ;
Nien, Hsin-Hua ;
Lui, Louis Tak ;
Shaw, Suzun ;
Tsai, Yu-Lun .
RADIATION ONCOLOGY, 2018, 13