Robust proportional resonant regulator for grid-connected voltage source inverter (VSI) using direct pole placement design method

被引:60
作者
Li, B. [2 ]
Yao, W. [2 ]
Hang, L. [1 ]
Tolbert, L. M. [1 ]
机构
[1] Univ Tennessee, Dept Elect Engn & Comp Sci EECS, Knoxville, TN 37996 USA
[2] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
System stability - Design - Electric inverters - Poles - Poles and zeros;
D O I
10.1049/iet-pel.2012.0102
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Based on the introduction of a dual-loop current control strategy for a grid-connected inverter, an averaged switching model of a grid-connected inverter with an LCL-filter in discrete domain is built under a stationary frame and a proportional resonant (PR) regulator is adopted in the current loop to track the given fundamental sinusoidal current. The impacts of PR parameters, LCL parameters and digital delay on the root locus are studied, respectively. The parameters of the LCL-filter and the PR current regulator loop are designed to assure system stability and dynamic response during a wide power range by using the pole placements method. Finally, a 10 kW prototype of a grid-connected inverter with an LCL-filter is set up to verify the effectiveness, the practicality and robustness of the proposed PR current design method.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 22 条
[11]  
Khan M.J, 2005, P IEEE CAN C EL COMP, P583
[12]   Design and control of an LCL-filter-based three-phase active rectifier [J].
Liserre, M ;
Blaabjerg, F ;
Hansen, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1281-1291
[13]   A Universal Grid-Connected Fuel-Cell Inverter for Residential Application [J].
Mazumder, Sudip K. ;
Burra, Rajni K. ;
Huang, Rongjun ;
Tahir, Muhammad ;
Acharya, Kaustuva .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (10) :3431-3447
[14]   Multilevel Inverter For Grid-Connected PV System Employing Digital PI Controller [J].
Selvaraj, Jeyraj ;
Rahim, Nasrudin A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (01) :149-158
[15]   A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter [J].
Shen, Guoqiao ;
Zhu, Xuancai ;
Zhang, Jun ;
Xu, Dehong .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (06) :2033-2041
[16]   A Combined Hard and Soft Variable-Structure Control Scheme for a Class of Nonlinear Systems [J].
Su, Juhng-Perng ;
Lee, Ting-En ;
Yu, Ker-Wei .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (09) :3305-3313
[17]   Proportional-resonant controllers and filters for grid-connected voltage-source converters [J].
Teodorescu, R. ;
Blaabjerg, F. ;
Liserre, M. ;
Loh, P. C. .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (05) :750-762
[18]   Robust High-Performance Inverter Control Using Discrete Direct-Design Pole Placement [J].
Turner, Robert ;
Walton, Simon ;
Duke, Richard .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :348-357
[19]   Full Feedforward of Grid Voltage for Grid-Connected Inverter With LCL Filter to Suppress Current Distortion Due to Grid Voltage Harmonics [J].
Wang, Xuehua ;
Ruan, Xinbo ;
Liu, Shangwei ;
Tse, Chi K. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (12) :3119-3127
[20]   A Robust Control Scheme for Grid-Connected Voltage-Source Inverters [J].
Yang, Shuitao ;
Lei, Qin ;
Peng, Fang Z. ;
Qian, Zhaoming .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :202-212