Objective breast symmetry evaluation using 3-D surface imaging

被引:49
|
作者
Eder, Maximilian [1 ]
v. Waldenfels, Fee [1 ]
Swobodnik, Alexandra [1 ]
Kloeppel, Markus [3 ]
Pape, Ann-Kathrin [1 ]
Schuster, Tibor [2 ]
Raith, Stefan [1 ]
Kitzler, Elena [1 ]
Papadopulos, Nikolaos A. [1 ]
Machens, Hans-Guenther [1 ]
Kovacs, Laszlo [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Plast Surg & Hand Surg, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
[3] Clin Esthet Surg MediCtr Munchen Solln, D-81479 Munich, Germany
来源
BREAST | 2012年 / 21卷 / 02期
关键词
Asymmetry; Breast surgery; Outcome research; Surface imaging; 3-D; AESTHETIC EVALUATION; VOLUME ASSESSMENT; VALUABLE ADJUNCT; SHAPE;
D O I
10.1016/j.breast.2011.07.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study develops an objective breast symmetry evaluation using 3-D surface imaging (Konica-Minolta V910 (R) scanner) by superimposing the mirrored left breast over the right and objectively determining the mean 3-D contour difference between the 2 breast surfaces. 3 observers analyzed the evaluation protocol precision using 2 dummy models (n = 60), 10 test subjects (n = 300), clinically tested it on 30 patients (n = 900) and compared it to established 2-D measurements on 23 breast reconstructive patients using the BCCT.core software (n = 690). Mean 3-D evaluation precision, expressed as the coefficient of variation (VC), was 3.54 +/- 0.18 for all human subjects without significant intra- and inter-observer differences (p > 0.05). The 3-D breast symmetry evaluation is observer independent, significantly more precise (p < 0.001) than the BCCT.core software (VC = 6.92 +/- 0.88) and may play a part in an objective surgical outcome analysis after incorporation into clinical practice. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 50 条
  • [1] Evaluation of Vectra® XT 3D Surface Imaging Technology in Measuring Breast Symmetry and Breast Volume
    Dennis C. Hammond
    Aesthetic Plastic Surgery, 2023, 47 : 8 - 9
  • [2] Evaluation of Vectra® XT 3D Surface Imaging Technology in Measuring Breast Symmetry and Breast Volume
    Hammond, Dennis C. C.
    AESTHETIC PLASTIC SURGERY, 2023, 47 (01) : 8 - 9
  • [3] Evaluation of Vectra Xt 3D Surface Imaging Technology in Measuring Breast Symmetry and Breast Volume
    Pham, My
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2023, 236 (05) : S9 - S9
  • [4] Evaluation of Vectra® XT 3D Surface Imaging Technology in Measuring Breast Symmetry and Breast Volume
    My Pham
    Robert Alzul
    Elisabeth Elder
    James French
    Jaime Cardoso
    Ahmad Kaviani
    Farid Meybodi
    Aesthetic Plastic Surgery, 2023, 47 : 1 - 7
  • [5] En Route for Objective Evaluation of Form, Volume, and Symmetry in Plastic Surgery using 3-D Intraoperative Scans
    Koban, K. C.
    Schenck, T.
    Metz, P. M.
    Volkmer, E.
    Haertnagl, F.
    Titze, V.
    Giunta, R. E.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2016, 48 (02) : 78 - 84
  • [6] 3-D line scan imaging with orthogonal symmetry
    Svetkoff, DJ
    Kilgus, DB
    Boman, RC
    THREE-DIMENSIONAL AND UNCONVENTIONAL IMAGING FOR INDUSTRIAL INSPECTION AND METROLOGY, 1996, 2599 : 177 - 188
  • [7] An objective evaluation of breast symmetry and shape differences using 3-dimensional images
    Losken, A
    Fishman, I
    Denson, DD
    Moyer, HR
    Carlson, GW
    ANNALS OF PLASTIC SURGERY, 2005, 55 (06) : 571 - 575
  • [8] 3-D Microwave Imaging for Breast Cancer
    Cheng, George
    Zhu, Yong
    Grzesik, Jan
    RADIOENGINEERING, 2012, 21 (04)
  • [9] CLINICAL EVALUATION OF A 3-D AUTOMATIC ANNOTATION METHOD FOR BREAST ULTRASOUND IMAGING
    Jiang, Wei-Wei
    Li, Cheng
    Li, An-Hua
    Zheng, Yong-Ping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (04): : 870 - 881
  • [10] Evaluation of radiotherapy setup accuracy for head and neck cancer using a 3-D surface imaging system
    Cho, H. -L.
    Park, E. -T.
    Kim, J. -Y.
    Kwak, K. -S.
    Kim, C. -J.
    Ahn, K. -J.
    Suh, T. -S.
    Lee, Y. -K.
    Kim, S. -W.
    Kim, J. -K.
    Lim, S.
    Choi, Y. -M.
    Park, S. -K.
    JOURNAL OF INSTRUMENTATION, 2013, 8