Analysis of coffee for the presence of acrylamide by LC-MS/MS

被引:145
|
作者
Andrzejewski, D [1 ]
Roach, JAG [1 ]
Gay, ML [1 ]
Musser, SM [1 ]
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, Instrumentat & Biophys Branch, College Pk, MD 20740 USA
关键词
acrylamide; LC-MS/MS; coffee; FDA;
D O I
10.1021/jf0349634
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A variety of popular instant, ground, and brewed coffees were analyzed using a modified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method specifically developed for the determination of acrylamide in foods. Coffee test portions were spiked with C-13(3)-labeled acrylamide as an internal standard prior to their extraction and cleanup. Ground coffees (1 g) and instant coffees (0.5 g) were extracted by shaking with 9 mL of water for 20 min. Brewed coffee test portions (9 mL) were taken through the cleanup procedure without further dilution with extraction solvent. Coffee test portions were cleaned up by passing 1.5 mL first through an Oasis HLB (hydrophilic/lipophilic copolymer sorbent) solid phase extraction (SPE) cartridge and then a Bond Elut-Accucat (cation and anion exchange sorbent) SPE cartridge. The cleaned up extracts were analyzed by positive ion electrospray LC-MS/MS. The MS/MS data was used to detect, confirm, and quantitate acrylamide. The limit of quantitation of the method was 10 ng/g for ground and instant coffees and 1.0 ng/mL for brewed coffee. The levels of acrylamide ranged from 45 to 374 ng/g in unbrewed coffee grounds, from 172 to 539 ng/g in instant coffee crystals, and from 6 to 16 ng/mL in brewed coffee.
引用
收藏
页码:1996 / 2002
页数:7
相关论文
共 50 条
  • [21] Analysis of residual neomycin in honey by LC-MS/MS
    Shim, Young-Eun
    Jeong, Ji-Yoon
    Myung, Seung-Woon
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2009, 22 (04): : 319 - 325
  • [22] Determination of Captopril in Rat Plasma by LC-MS/MS in Presence of Apigenin
    Siska
    Suyatna, Franciscus D.
    Mun'im, Abdul
    Bahtiar, Anton
    Priyanto
    ADVANCED SCIENCE LETTERS, 2017, 23 (12) : 12447 - 12450
  • [23] Quantitative Analysis of Clenbuterol in Pig Liver by LC-MS/MS/MS
    Hayashi, Takako
    Fujimaki, Teruhisa
    Miyazawa, Maki
    CHROMATOGRAPHY, 2018, 39 (03) : 131 - 137
  • [24] Development and validation of LC-MS/MS method for trace analysis of acrylamide, acrylic acid and N, N-methylene bis acrylamide in sandy loam soil
    Talaviya, Harshang
    Singh, Anupama
    Singh, Neera
    Manna, Suman
    Banerjee, Tirthankar
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1729
  • [25] Determination of Clenbuterol in Various Edible Parts of Livestock Products by LC-MS/MS and LC-MS/MS/MS Methods
    HAYASHI, Takako
    HAMASE, Kenji
    CHROMATOGRAPHY, 2021, 42 (01) : 43 - 48
  • [26] Quality control in LC-MS/MS
    Koecher, Thomas
    Pichler, Peter
    Swart, Remco
    Mechtler, Karl
    PROTEOMICS, 2011, 11 (06) : 1026 - 1030
  • [27] LC-MS/MS in clinical laboratories
    Kushnir, Mark M.
    Rockwood, Alan L.
    Bergquist, Jonas
    BIOANALYSIS, 2013, 5 (01) : 5 - 6
  • [28] Analysis of Nitrosamines Concentration in Condom by using LC-MS/MS
    Park, Na-Youn
    Kim, Sungmin
    Jung, Woong
    Kho, Younglim
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2018, 62 (03): : 181 - 186
  • [29] The resistance of metallothionein to proteolytic digestion : An LC-MS/MS analysis
    Wang, Rongying
    Sens, Donald A.
    Garrett, Scott
    Somji, Seema
    Sens, Mary Ann
    Lu, Xiaoning
    ELECTROPHORESIS, 2007, 28 (16) : 2942 - 2952
  • [30] An LC-MS/MS analysis for seven sex hormones in serum
    Yuan, Teng-Fei
    Le, Juan
    Cui, Yan
    Peng, Rui
    Wang, Shao-Ting
    Li, Yan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 34 - 40