Designs and Techniques That Improve the Pullout Strength of Pedicle Screws in Osteoporotic Vertebrae: Current Status

被引:129
作者
Shea, Thomas M. [1 ,2 ]
Laun, Jake [3 ]
Gonzalez-Blohm, Sabrina A. [1 ]
Doulgeris, James J. [1 ,4 ]
Lee, William E., III [4 ]
Aghayev, Kamran [1 ,5 ,6 ]
Vrionis, Frank D. [1 ,5 ,6 ]
机构
[1] H Lee Moffitt Canc Ctr Res Inst, Dept Neurooncol, Tampa, FL 33612 USA
[2] Univ S Florida, Dept Chem & Biomed Engn, Tampa, FL 33620 USA
[3] Univ S Florida, Morsani Coll Med, Tampa, FL 33612 USA
[4] Univ S Florida, Dept Mech Engn, Tampa, FL 33620 USA
[5] Univ S Florida, Morsani Coll Med, Dept Neurosurg, Tampa, FL 33612 USA
[6] Univ S Florida, Morsani Coll Med, Dept Orthoped, Tampa, FL 33612 USA
关键词
CALCIUM-PHOSPHATE CEMENT; BIOMECHANICAL ANALYSIS; FIXATION STRENGTH; INSERTIONAL TORQUE; CORTICAL BONE; AUGMENTATION; INSTRUMENTATION; SPINE; SIZE; HOLE;
D O I
10.1155/2014/748393
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Osteoporosis is a medical condition affecting men and women of different age groups and populations. The compromised bone quality caused by this disease represents an important challenge when a surgical procedure (e. g., spinal fusion) is needed after failure of conservative treatments. Different pedicle screw designs and instrumentation techniques have been explored to enhance spinal device fixation in bone of compromised quality. These include alterations of screw thread design, optimization of pilot hole size for non-self-tapping screws, modification of the implant's trajectory, and bone cement augmentation. While the true benefits and limitations of any proceduremay not be realized until they are observed in a clinical setting, axial pullout tests, due in large part to their reproducibility and ease of execution, are commonly used to estimate the device's effectiveness by quantifying the change in force required to remove the screw from the body. The objective of this investigation is to provide an overview of the different pedicle screw designs and the associated surgical techniques either currently utilized or proposed to improve pullout strength in osteoporotic patients. Mechanical comparisons as well as potential advantages and disadvantages of each consideration are provided herein.
引用
收藏
页数:15
相关论文
共 91 条
[11]   Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine [J].
Carmouche, JJ ;
Molinari, RW ;
Gerlinger, T ;
Devine, J ;
Patience, T .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 3 (05) :364-370
[12]   Increasing bending strength and pullout strength in conical pedicle screws: Biomechanical tests and finite element analyses [J].
Chao, Ching-Kong ;
Hsu, Ching-Chi ;
Wang, Jaw-Lin ;
Lin, Jinn .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (02) :130-138
[13]   Biomechanical analysis of different types of pedicle screw augmentation: A cadaveric and synthetic bone sample study of instrumented vertebral specimens [J].
Chao, Kuo-Hua ;
Lai, Yu-Shu ;
Chen, Wen-Chuan ;
Chang, Chia-Ming ;
McClean, Colin J. ;
Fan, Chang-Yuan ;
Chang, Chia-Hao ;
Lin, Leou-Chyr ;
Cheng, Cheng-Kung .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) :1506-1512
[14]   Diabetes Mellitus, Glycemic Control, and Pneumonia in Long-Term Care Facilities: A 2-Year, Prospective Cohort Study [J].
Chen, Liang-Kung ;
Peng, Li-Ning ;
Lin, Ming-Hsien ;
Lai, Hsiu-Yun ;
Lin, Hsin-Chieh ;
Hwang, Shinn-Jang .
JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2011, 12 (01) :33-37
[15]   Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: Influences of radial hole and pilot hole tapping [J].
Chen, Lih-Huei ;
Tai, Ching-Lung ;
Lai, Po-Liang ;
Lee, De-Mei ;
Tsai, Tsung-Tin ;
Fu, Tsai-Sheng ;
Niu, Chi-Chien ;
Chen, Wen-Jer .
CLINICAL BIOMECHANICS, 2009, 24 (08) :613-618
[16]  
Cheng Marilyn Lee, 2013, Indian J Endocrinol Metab, V17, P240, DOI 10.4103/2230-8210.109681
[17]   The biomechanics of pedicle screw-based instrumentation [J].
Cho, W. ;
Cho, S. K. ;
Wu, C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08) :1061-1065
[18]   Titanium-alloy enhances bone-pedicle screw fixation:: mechanical and histomorphometrical results of titanium-alloy versus stainless steel [J].
Christensen, FB ;
Dalstra, M ;
Sejling, F ;
Overgaard, S ;
Bünger, C .
EUROPEAN SPINE JOURNAL, 2000, 9 (02) :97-103
[19]  
Cook S D, 2001, Spine J, V1, P109, DOI 10.1016/S1529-9430(01)00020-1
[20]  
Cook Stephen D, 2004, Spine J, V4, P402, DOI 10.1016/j.spinee.2003.11.010