Imaging Errors in Localization of COMS-Type Plaques in Choroidal Melanoma Brachytherapy

被引:7
作者
Bayat, Mahdi [1 ]
Alizad, Azra [2 ]
Tamminga, Rachel [3 ]
Pulido, Jose S. [4 ]
Fatemi, Mostafa [2 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN USA
[2] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[3] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
[4] Mayo Clin, Coll Med, Dept Ophthalmol, Rochester, MN 55905 USA
关键词
ultrasound; transillumination; brachytherapy; INTRAOPERATIVE ECHOGRAPHIC LOCALIZATION; DIODE-LIGHT TRANSILLUMINATION; RADIOACTIVE PLAQUES; ACCURATE PLACEMENT;
D O I
10.1167/iovs.12-11499
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate mathematically and experimentally the sources of errors in localization of COMS-type plaques in melanoma brachytherapy when using ultrasound and transillumination and to give recommendations to avoid such errors. METHODS. A computer-aided simulation tool was developed to model the errors seen in the patient images when using ultrasound imaging and transillumination during localization of the COMS-type plaque in melanoma brachytherapy. Several laboratory experiments were performed on sheep eyes to confirm the validity of the error sources and the simulator outputs. Results were compared to the intraoperative ultrasonographic patient images for validation. RESULTS. Based on mathematical modeling and computer simulation results, transillumination provides acceptable accuracy for small to medium tumors with less than 7-mm height but shows poor accuracy as the tumor height increases. In ultrasound imaging, two sources of error are predicted in longitudinal scan using our computer simulation modeling, and the results are supported by the experiments on sheep eyes and patient images taken during the operation. Both errors are related to the lens. The first error is due to attenuation and refraction of the lens causing opaque areas and a change of curvature in the image of the plaque edge that is nearest to the lens. The second type of error is related to the total internal reflection from the lens. CONCLUSIONS. The simulation method presented in this article allows quantitative assessment of the sources, mechanisms, and measures of errors in localization of the CMOS-type plaques by ultrasound and transillumination techniques. Errors predicted by the simulation method are validated by experiments. Error assessment by this method provides guidelines for avoiding such errors.
引用
收藏
页码:6852 / 6859
页数:8
相关论文
共 17 条
[1]  
[Anonymous], 1990, PHYS PROPERTIES TISS
[2]  
[Anonymous], 2009, OPHTHALMOLOGY
[3]  
Byrne SF, 2002, ULTRASOUND EYE ORBIT, V15-44, P115
[4]  
Collaborative Ocular Melanoma Grp, 2006, ARCH OPHTHALMOL-CHIC, V124, P1684
[5]   Diode-light transillumination for ophthalmic plaque localization around juxtapapillary choroidal melanomas [J].
Finger, PT ;
Iezzi, R ;
Esteveo, ML ;
Szechter, A ;
Rosen, RB ;
Berson, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04) :887-890
[6]  
Finger PT, 1999, ARCH OPHTHALMOL-CHIC, V117, P179
[7]   Radiation therapy for choroidal melanoma [J].
Finger, PT .
SURVEY OF OPHTHALMOLOGY, 1997, 42 (03) :215-232
[8]   Intraoperative echographic localization of iodine 125 episcleral radioactive plaques for posterior uveal melanoma [J].
Harbour, JW ;
Murray, TG ;
Byrne, SF ;
Hughes, JR ;
Gendron, EK ;
Ehlies, FJ ;
Markoe, AM .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1996, 16 (02) :129-134
[9]   Transillumination for accurate placement of radioactive plaques in brachytherapy of choroidal melanoma [J].
Krohn, J ;
Seland, JH ;
Monge, OR ;
Rekstad, BL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (03) :418-419
[10]   The comet-tail artifact - An ultrasound sign of alveolar-interstitial syndrome [J].
Lichtenstein, D ;
Meziere, G ;
Biderman, P ;
Gepner, A ;
Barre, O .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (05) :1640-1646