R1 dispersion contrast at high field with fast field-cycling MRI

被引:15
|
作者
Boedenler, Markus [1 ]
Basini, Martina [2 ,3 ]
Casula, Maria Francesca [4 ,5 ]
Umut, Evrim [6 ]
Goesweiner, Christian [1 ]
Petrovic, Andreas [1 ]
Kruk, Danuta [6 ]
Scharfetter, Hermann [1 ]
机构
[1] Graz Univ Technol, Inst Med Engn, Stremayrgasse 16, A-8010 Graz, Austria
[2] Univ Milan, Phys Dept, Via Celoria 16, I-20133 Milan, Italy
[3] Univ Milan, INSTM, Via Celoria 16, I-20133 Milan, Italy
[4] Univ Cagliari, Dept Chem & Soil Sci, I-09042 Monserrato, CA, Italy
[5] Univ Cagliari, INSTM, I-09042 Monserrato, CA, Italy
[6] Univ Warmia & Mazury, Fac Math & Comp Sci, Sloneczna 54, PL-10710 Olsztyn, Poland
关键词
Fast field-cycling; Dispersion; Delta relaxation enhanced MR; MRI; Quadrupole relaxation enhancement; Contrast agent; RELAXATION ENHANCED MR; MAGNETIC-RESONANCE; AGENTS;
D O I
10.1016/j.jmr.2018.03.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contrast agents with a strong R-1 dispersion have been shown to be effective in generating target-specific contrast in MRI. The utilization of this R-1 field dependence requires the adaptation of an MRI scanner for fast field-cycling (FFC). Here, we present the first implementation and validation of FFC-MRI at a clinical field strength of 3 T. A field-cycling range of +/- 100 mT around the nominal Bo field was realized by inserting an additional insert coil into an otherwise conventional MRI system. System validation was successfully performed with selected iron oxide magnetic nanoparticles and comparison to FFC-NMR relaxometry measurements. Furthermore, we show proof-of-principle R-1 dispersion imaging and demonstrate the capability of generating R-1 dispersion contrast at high field with suppressed background signal. With the presented ready-to-use hardware setup it is possible to investigate MRI contrast agents with a strong R-1 dispersion at a field strength of 3 T. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [21] Field-cycling NMR experiments in an ultra-wide magnetic field range: relaxation and coherent polarization transfer
    Zhukov, Ivan V.
    Kiryutin, Alexey S.
    Yurkovskaya, Alexandra V.
    Grishin, Yuri A.
    Vieth, Hans-Martin
    Ivanov, Konstantin L.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2018, 20 (18) : 12396 - 12405
  • [22] Perspectives of Deuteron Field-Cycling NMR Relaxometry for Probing Molecular Dynamics in Soft Matter
    Flaemig, M.
    Becher, M.
    Hofinann, M.
    Koerber, T.
    Kresse, B.
    Privalov, A. F.
    Willner, L.
    Kruk, D.
    Fujara, F.
    Roessler, E. A.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2016, 120 (31) : 7754 - 7766
  • [23] Proton Double Irradiation Field-Cycling Nuclear Magnetic Resonance Imaging: Testing New Concepts and Calibration Methods
    Rodriguez, Gonzalo Gabriel
    Anoardo, Esteban
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [24] Data-Driven Retrospective Correction of B1 Field Inhomogeneity in Fast Macromolecular Proton Fraction and R1 Mapping
    Yarnykh, Vasily L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3473 - 3484
  • [25] Fluorinated MRI contrast agents and their versatile applications in the biomedical field
    Hequet, Emilie
    Henoumont, Celine
    Muller, Robert N.
    Laurent, Sophie
    FUTURE MEDICINAL CHEMISTRY, 2019, 11 (10) : 1157 - 1175
  • [26] A dual-core NMR system for field-cycling singlet assisted diffusion NMR
    Robertson, Thomas B. R.
    Bannister, Rose C.
    Cartlidge, Topaz A. A.
    Hugger, Thimo
    Breham, Sebastien
    Zick, Klaus
    Engelke, Frank
    Thompson, Sam
    Pileio, Giuseppe
    FRONTIERS IN CHEMISTRY, 2023, 11
  • [27] Low-field MRI can be more sensitive than high-field MRI
    Coffey, Aaron M.
    Truong, Milton L.
    Chekmenev, Eduard Y.
    JOURNAL OF MAGNETIC RESONANCE, 2013, 237 : 169 - 174
  • [28] R1ρ dispersion and sodium imaging in human calf muscle
    Wang, Ping
    Zhu, He
    Kang, Hakmook
    Gore, John C.
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 139 - 143
  • [29] Effect of r1 and r2 relaxivity of gadolinium-based contrast agents on the T1-weighted MR signal at increasing magnetic field strengths
    Hagberg, Gisela E.
    Scheffler, Klaus
    CONTRAST MEDIA & MOLECULAR IMAGING, 2013, 8 (06) : 456 - 465
  • [30] Future demands for high field MRI diagnostic
    Gautam, Anurag
    Komal, Pragya
    Singh, Ram Sevak
    JOURNAL OF CHEMICAL SCIENCES, 2019, 131 (09)