Dosimetric comparison between IMRT and VMAT in irradiation for peripheral and central lung cancer

被引:41
作者
Li, Yi [1 ]
Wang, Ji [2 ]
Tan, Li [3 ]
Hui, Beina [1 ]
Ma, Xiaowei [3 ]
Yan, Yanli [3 ]
Xue, Chaofan [3 ]
Shi, Xiaoting [1 ]
Drokow, Emmanuel Kwateng [1 ]
Ren, Juan [1 ]
机构
[1] Xi An Jiao Tong Univ, Oncol Dept, Dept Radiotherapy, Affiliated Hosp 1, 277 Yanta West Rd, Xian 710061, Shaanxi, Peoples R China
[2] China Meitan Gen Hosp, Intens Care Unit, Beijing 100028, Peoples R China
[3] Xi An Jiao Tong Univ, Med Sch, Xian 710061, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
intensity-modulated radiation therapy; volumetric modulated arc therapy; central lung cancer; peripheral lung cancer; dosimetry; VOLUMETRIC MODULATED ARC; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; FIXED FIELD IMRT; RADIATION PNEUMONITIS; PROSTATE-CANCER; HISTOGRAM ANALYSIS; 78; GY; THERAPY; DELIVERY; TOMOTHERAPY;
D O I
10.3892/ol.2018.7732
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to compare intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in irradiation of lung cancer. Plans of 14 patients were compared. The results demonstrated that in peripheral lung cancer, V5 (%) of the lung in partial-arc (PA)-VMAT was decreased compared with IMRT, single-arc (SA)-, and double partial-arc (2PA)-VMAT. V30 (%) of the lung in IMRT was decreased compared with SA-, PA- and 2PA-VMAT. In the case of planning target volume (PTV) not encompassing the mediastinum in central lung cancer, the conformality index (CI) and heterogeneity index (HI) of SA-VMAT was improved compared with IMRT, PA-, and 2PA-VMAT. The received dose of heart in SA-VMAT was higher compared with IMRT, PA- and 2PA-VMAT. V30 (%) and V5 (%) of the lung in IMRT was higher compared with SA-, PA- and 2PA-VMAT; V10 (%) of the lung in 2PA was decreased compared with IMRT, SA- and PA. In the case of PTV encompassing the mediastinum in central lung cancer, the HI and CI of 2PA was improved compared with IMRT, SA- and PA-VMAT. The received dose of heart in 2PA was higher compared with IMRT, SA- and PA-VMAT. V30 (%) and V5 (%) of the lung in 2PA-VMAT was higher compared with IMRT, SA- and PA-VMAT. V20 (%) of the lung in 2PA was decreased compared with IMRT, SA- and PA-VMAT. In conclusion, it may be necessary to classify the radiotherapy plans of lung cancer into three categories including peripheral lung cancer, PTV not encompassing the mediastinum of central lung cancer, and PTV encompassing the mediastinum of central lung cancer. Each of IMRT, SA-VMAT, PA-VMAT, 2PA-VMAT strategy had individual advantages, and therefore it may be crucial to employ different planning techniques for different disease classifications and OAR requirements.
引用
收藏
页码:3735 / 3745
页数:11
相关论文
共 40 条
  • [1] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [2] SOLUTION OF AN INTEGRAL-EQUATION ENCOUNTERED IN ROTATION THERAPY
    BRAHME, A
    ROOS, JE
    LAX, I
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (10) : 1221 - 1229
  • [3] 2-Step IMAT and 2-Step IMRT in three dimensions
    Bratengeier, K
    [J]. MEDICAL PHYSICS, 2005, 32 (12) : 3849 - 3861
  • [4] Can all centers plan intensity-modulated radiotherapy (IMRT) effectively? An external audit of dosimetric comparisons between three-dimensional conformal radiotherapy and IMRT for adjuvant chemoradiation for gastric cancer
    Chung, Hans T.
    Lee, Brian
    Park, Eileen
    Lu, Jiade J.
    Xia, Ping
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1167 - 1174
  • [5] A prospective study on radiation pneumonitis following conformal radiation therapy in non-small-cell lung cancer:: clinical and dosimetric factors analysis
    Claude, L
    Pérol, D
    Ginestet, C
    Falchero, L
    Arpin, D
    Vincent, M
    Martel, I
    Hominal, S
    Cordier, JF
    Carrie, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 (02) : 175 - 181
  • [6] Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT
    Clivio, Alessandro
    Fogliata, Antonella
    Franzetti-Pellanda, Alessandra
    Nicolini, Giorgia
    Vanetti, Eugenio
    Wyttenbach, Rolf
    Cozzi, Luca
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 (01) : 118 - 124
  • [7] A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy
    Cozzi, Luca
    Dinshaw, Ketayun Ardeshir
    Shrivastava, Shyam Kishore
    Mahantshetty, Umesh
    Engineer, Reena
    Deshpande, Deepak Dattatray
    Jamema, S. V.
    Vanetti, Eugenio
    Clivio, Alessandro
    Nicolini, Giorgia
    Fogliata, Antonella
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) : 180 - 191
  • [8] Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    Graham, MV
    Purdy, JA
    Emami, B
    Harms, W
    Bosch, W
    Lockett, MA
    Perez, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 323 - 329
  • [9] Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?
    Guckenberger, Matthias
    Richter, Anne
    Krieger, Thomas
    Wilbert, Juergen
    Baier, Kurt
    Flentje, Michael
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) : 259 - 265
  • [10] Radiation-induced pulmonary toxicity: A dose-volume histogram analysis in 201 patients with lung cancer
    Hernando, ML
    Marks, LB
    Bentel, GC
    Zhou, SM
    Hollis, D
    Das, SK
    Fan, M
    Munley, MT
    Shafman, TD
    Anscher, MS
    Lind, PA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (03): : 650 - 659