Harmonic Spectrum Analysis of Induction Motor With Broken Rotor Bar Fault

被引:0
|
作者
Asad, Bilal [1 ]
Vaiman, Toomas [1 ]
Kallaste, Ants [1 ]
Belahcen, Anouar [2 ]
机构
[1] Tallinn Univ Technol, Dept Elect Power Engn & Mechatron, Tallinn, Estonia
[2] Aalto Univ, Dept Elect Engn & Automat, Espoo, Finland
来源
2018 IEEE 59TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON) | 2018年
关键词
digital filters; fault diagnosis; induction motors; Fourier transform; DIAGNOSIS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper,the frequency spectrum of a three-phase induction motor's stator current on a linear scale is investigated. The broken rotor bar, spatial and grid fed harmonics are taken into consideration. Since the fundamental component of the power supply is always the most powerful component, it makes the spectrum less legible, increases the spectral leakage and makes the logarithmic scale inevitable. In this paper, a Chebyshev filter is used for attenuation of the fundamental component, because of its good transition band and no passhand ripples. The current signals are taken from both simulation and laboratory environment and harmonics due to above-mentioned causes are segregated.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Analysis of Broken Rotor bar Fault Diagnosis for Induction Motor
    Sharma, Amandeep
    Mathew, Lini
    Chatterji, Shantanu
    2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN CONTROL, COMMUNICATION AND INFORMATION SYSTEMS (ICICCI-2017), 2017, : 492 - 496
  • [2] Induction motor broken rotor bar fault detection techniques based on fault signature analysis - a review
    Hassan, Ola E.
    Amer, Motaz
    Abdelsalam, Ahmed K.
    Williams, Barry W.
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (07) : 895 - 907
  • [3] A Survey of Broken Rotor Bar Fault Diagnostic Methods of Induction Motor
    Asad, Bilal
    Vaimann, Toomas
    Rassolkin, Anton
    Kallaste, Ants
    Belahcen, Anouar
    ELECTRICAL CONTROL AND COMMUNICATION ENGINEERING, 2018, 14 (02) : 117 - 124
  • [4] Efficiency Analysis of Submersible Induction Motor with Broken Rotor Bar
    Arabaci, Hayri
    Bilgin, Osman
    TRANSACTIONS ON ENGINEERING TECHNOLOGIES: SPECIAL ISSUE OF THE WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE 2013, 2014, : 27 - 40
  • [5] Virtual Sensors for Fault Diagnosis: A Case of Induction Motor Broken Rotor Bar
    Hosseinpoor, Zahra
    Arefi, Mohammad Mehdi
    Razavi-Far, Roozbeh
    Mozafari, Niloofar
    Hazbavi, Saeede
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 5044 - 5051
  • [6] Simulation of Broken Rotor Bar Fault by Asymmetric Induction Motor Model
    Djagarov, Nikolay
    Enchev, Georgi
    Djagarova, Julia
    2022 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING (DIAGNOSTIKA), 2022, : 117 - 124
  • [7] Using Motor Current Analysis for Broken Rotor Bar Fault Detection in Rotary Machines
    Sharma, Amandeep
    Verma, Pankaj
    Mathew, Lini
    Chatterji, Shantanu
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON COMMUNICATION AND ELECTRONICS SYSTEMS (ICCES 2018), 2018, : 329 - 334
  • [8] Improving Legibility of Motor Current Spectrum for Broken Rotor Bars Fault Diagnostics
    Asad, Bilal
    Vaimann, Toomas
    Kallaste, Ants
    Rassolkin, Anton
    Belahcen, Anouar
    Iqbal, M. Naveed
    ELECTRICAL CONTROL AND COMMUNICATION ENGINEERING, 2019, 15 (01) : 1 - 8
  • [9] Broken Rotor Bar Fault Detection Analysis
    Sun, Liling
    Chen, Kaibin
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 1862 - 1866
  • [10] Induction Motor Broken Rotor Bar Detection Based on Rotor Flux Angle Monitoring
    Nemec, Mitja
    Ambrozic, Vanja
    Fiser, Rastko
    Nedeljkovic, David
    Drobnic, Klemen
    ENERGIES, 2019, 12 (05)