In vivo biocompatibility and degradation studies of polyhydroxyoctanoate in the rat:: A new sealant for the polyester arterial prosthesis

被引:26
作者
Marois, Y
Zhang, Z
Vert, M
Beaulieu, L
Lenz, RW
Guidoin, R
机构
[1] Univ Montpellier I, Fac Pharm, CRBA, CNRS,URA 1465, Montpellier, France
[2] Univ Laval, Quebec Biomat Inst, Ctr Rech, CHUQ,Dept Surg,Lab Expt Surg, Quebec City, PQ G1K 7P4, Canada
[3] Univ Massachusetts, Amherst, MA 01003 USA
来源
TISSUE ENGINEERING | 1999年 / 5卷 / 04期
关键词
D O I
10.1089/ten.1999.5.369
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The present study examined the biocompatibility and degradation properties of poly (beta-hydroxy octanoate) (PHO) as an impregnation substrate on arterial prostheses. PHO-impregnated polyester grafts sterilized by ethylene oxide (EO) or gamma (gamma) radiation, and polyester Dacron(R) prostheses impregnated with fluoropolymer, gelatin, or albumin were implanted subcutaneously in rats for periods ranging from 2 to 180 days. The biocompatibility was assessed by quantifying the alkaline and acid phosphatase secretion while performing histological studies at the tissue/prosthesis interface. The degradation was determined by chemical analysis of the EO and gamma-sterilized PHO after implantation using differential scanning calorimetry (DSC), wide angle x-ray diffraction (WAXD), and size exclusion chromatography (SEC). Alkaline phosphatase activity by the sterilized PHO and by the gelatin and albumin grafts was significantly elevated early after implantation in contrast to that of the Dacron and fluoropolymer grafts that occurred later, at 7 and 5 days, respectively The peak of acid phosphatase activity for all of the grafts occurred between 5 and 10 days postimplantation, with the gamma-sterilized PHO grafts recording the greatest activity. Histological study revealed that the tissue incorporation into the graft wall was earlier and more complete for the Dacron and fluoropolymer grafts after 6 months than for the gelatin and albumin grafts, because the latter induced important inflammatory reactions during the resorption of the cross-linked protein substrates. The EO and gamma-sterilized PHO grafts exhibited a similar healing sequence characterized by the development of a collagenous tissue surrounding the prostheses. However, no infiltration of tissue into the graft wall was observed after 6 months, mainly because of the presence of the PHO. Degradation of the EO and gamma-sterilized PHO occurred preferentially by a hydrolytic mechanism as shown by a 30% molecular weight decrease after 6 months. In conclusion, PHO showed good biocompatibility in terms of enzyme activity and tissue reaction. Degradation was a slow, in vivo process controlled primarily by a random hydrolytic reaction and by a local enzymatic attack by macrophages and giant cells.
引用
收藏
页码:369 / 386
页数:18
相关论文
共 31 条
[1]   SEVERE STENOTIC SCAR CONTRACTURE OF THE MICROVEL HEMASHIELD RIGHT-SIDED EXTRACARDIAC CONDUIT [J].
ANGELINI, GD ;
WITSENBURG, M ;
TENKATE, FJW ;
HIDDEMA, PAE ;
QUAEGEBEUR, JM .
ANNALS OF THORACIC SURGERY, 1989, 48 (05) :714-716
[2]  
[Anonymous], 1993, POLYM POLYM COMPOS
[3]  
BENSLIMANE S, 1987, BIOMATER ARTIF CELL, V15, P453
[4]  
BENSLIMANE S, 1988, EUR SURG RES, V20, P12
[5]  
Branchereau A, 1990, Ann Vasc Surg, V4, P138, DOI 10.1007/BF02001368
[6]   RADIATION STERILIZATION OF POLYMERIC IMPLANT MATERIALS [J].
BRUCK, SD ;
MUELLER, EP .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1988, 22 (A2) :133-144
[7]   THE EFFECT OF GAMMA-IRRADIATION ON COLLAGEN MOLECULES, ISOLATED ALPHA-CHAINS, AND CROSS-LINKED NATIVE FIBERS [J].
CHEUNG, DT ;
PERELMAN, N ;
TONG, D ;
NIMNI, ME .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (05) :581-589
[8]   New bioresorbable pin for the reduction of small bony fragments: Design, mechanical properties and in vitro degradation [J].
Claes, LE ;
Ignatius, AA ;
Rehm, KE ;
Scholz, C .
BIOMATERIALS, 1996, 17 (16) :1621-1626
[9]  
Drury J K, 1987, Ann Vasc Surg, V1, P542, DOI 10.1016/S0890-5096(06)61437-4
[10]   A BIODEGRADABLE PATCH USED AS A PERICARDIAL SUBSTITUTE AFTER CARDIAC-SURGERY - 6-MONTH AND 24-MONTH EVALUATION WITH CT [J].
DUVERNOY, O ;
MALM, T ;
RAMSTROM, J ;
BOWALD, S .
THORACIC AND CARDIOVASCULAR SURGEON, 1995, 43 (05) :271-274