Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens

被引:43
|
作者
Lorenz, Katrin [1 ]
Korb, Christina [1 ]
Herzog, Nicola [1 ]
Vetter, Jan M. [1 ]
Elflein, Heike [1 ]
Keilani, Munir M. [1 ]
Pfeiffer, Norbert [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, Univ Med Ctr, D-55131 Mainz, Germany
关键词
glaucoma; contact lens; intraocular pressure; 24-hour IOP profile; OPEN-ANGLE GLAUCOMA; INDEPENDENT RISK-FACTOR; NORMAL-TENSION GLAUCOMA; OCULAR HYPERTENSION; PROGRESSION; TONOMETER;
D O I
10.1097/IJG.0b013e318241b874
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and Methods: Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. Results: Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. Conclusions: This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 50 条
  • [31] Kontinuierliche AugeninnendruckmessungErste Ergebnisse einer drucksensitiven KontaktlinseContinuous intraocular pressure measurementFirst results with a pressure-sensitive contact lens
    A. Hediger
    C. Kniestedt
    S. Zweifel
    P. Knecht
    J. Funk
    H. Kanngiesser
    Der Ophthalmologe, 2009, 106 (12): : 1111 - 1115
  • [32] Analysis of Continuous 24-Hour Intraocular Pressure Patterns in Glaucoma
    Mansouri, Kaweh
    Liu, John H. K.
    Weinreb, Robert N.
    Tafreshi, Ali
    Medeiros, Felipe A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (13) : 8050 - 8056
  • [33] Evaluation of Continuous 24-Hour Intraocular Pressure Monitoring for Assessment of Prostaglandin-induced Pressure Reduction in Glaucoma
    Hollo, Gabor
    Kothy, Peter
    Vargha, Peter
    JOURNAL OF GLAUCOMA, 2014, 23 (01) : E6 - E12
  • [34] Intereye Symmetry of 24-Hour Intraocular Pressure-related Patterns in Untreated Glaucoma Patients Using a Contact Lens Sensor
    Mansouri, Kaweh
    Gillmann, Kevin
    JOURNAL OF GLAUCOMA, 2020, 29 (08) : 666 - 670
  • [35] First-in-human continuous 24-hour measurement of intraocular pressure and ocular pulsation using a novel contact lens sensor
    Wasilewicz, Robert
    Varidel, Thierry
    Simon-Zoula, Sonja
    Schlund, Mario
    Cerboni, Sacha
    Mansouri, Kaweh
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (11) : 1519 - 1523
  • [36] Continuous 24-hour measurement of intraocular pressure in millimeters of mercury (mmHg) using a novel contact lens sensor: Comparison with pneumatonometry
    Gillmann, Kevin
    Wasilewicz, Robert
    Hoskens, Kirsten
    Simon-Zoula, Sonja
    Mansouri, Kaweh
    PLOS ONE, 2021, 16 (03):
  • [37] Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma
    De Moraes, Carlos Gustavo
    Mansouri, Kaweh
    Liebmann, Jeffrey M.
    Ritch, Robert
    JAMA OPHTHALMOLOGY, 2018, 136 (07) : 779 - 785
  • [38] A 24-HOUR PH AND PRESSURE MONITORING DEVICE FOR OUTPATIENTS
    VANTRAPPEN, G
    SERVAES, J
    PEETERS, T
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 1981, 19 (08): : 422 - 423
  • [39] 24-Hour ambulatory blood pressure monitoring.
    O'Shea, J. Conor
    Calliff, Robert M.
    AMERICAN HEART JOURNAL, 2006, 151 (05) : 962 - 968
  • [40] AUTOMATIC 24-HOUR MONITORING OF BLOOD-PRESSURE
    BOGDANOV, MM
    KARDIOLOGIYA, 1985, 25 (01) : 90 - 93