Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens

被引:43
|
作者
Lorenz, Katrin [1 ]
Korb, Christina [1 ]
Herzog, Nicola [1 ]
Vetter, Jan M. [1 ]
Elflein, Heike [1 ]
Keilani, Munir M. [1 ]
Pfeiffer, Norbert [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, Univ Med Ctr, D-55131 Mainz, Germany
关键词
glaucoma; contact lens; intraocular pressure; 24-hour IOP profile; OPEN-ANGLE GLAUCOMA; INDEPENDENT RISK-FACTOR; NORMAL-TENSION GLAUCOMA; OCULAR HYPERTENSION; PROGRESSION; TONOMETER;
D O I
10.1097/IJG.0b013e318241b874
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and Methods: Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. Results: Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. Conclusions: This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 50 条
  • [21] Analysis of the diurnal intraocular pressure profile pre and post trabeculectomy using 24-hour monitoring of intraocular pressure
    Ross, Adam H.
    Jackson, Thomas E.
    Wertheim, Michael S.
    Spry, Paul G. D.
    Sparrow, John M.
    Diamond, Jeremy P.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (04) : 400 - 403
  • [22] Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Weinreb, Robert N.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09): : 787 - 795
  • [23] Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change
    Mansouri, Kaweh
    Weinreb, Robert N.
    SWISS MEDICAL WEEKLY, 2012, 142
  • [24] Simultaneous ambulatory 24-hour blood pressure monitoring and intraocular pressure-related patterns estimated with a contact-lens sensor in treated glaucoma patients
    Lee, Joseph H.
    De Moraes, Carlos Gustavo
    Mena, Luis J.
    Jin, Zhezhen
    Maestre, Gladys
    Liebmann, Jeffrey M.
    Ritch, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [25] A New Standard for 24-Hour Intraocular Pressure Studies
    Eisenberg, Dan
    OPHTHALMOLOGY, 2019, 126 (08) : 1105 - 1106
  • [26] 24-Hour Contact Lens Sensor Monitoring of Intraocular Pressure-Related Profiles in Normal-Tension Glaucoma and Rates of Disease Progression
    Hoban, Katie
    Peden, Robert
    Megaw, Roly
    Halpin, Patricia
    Tatham, Andrew J.
    OPHTHALMIC RESEARCH, 2017, 57 (04) : 208 - 215
  • [27] Automatic 24-hour blood pressure monitoring
    Gorbunov, VM
    KARDIOLOGIYA, 1997, 37 (06) : 96 - 104
  • [28] 24-hour ambulatory blood pressure monitoring
    Anlauf, M
    Baumgart, P
    Franz, IW
    Krönig, B
    Middeke, M
    Schrader, J
    Schulte, KL
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (47) : 1426 - 1430
  • [29] Association of Ambulatory Blood Pressure and Other FactorsWith Intraocular Pressure-Related 24-Hour Contact Lens Sensor Profile in Untreated Glaucoma
    Nakazawa, Kazuki
    Higashide, Tomomi
    Tsuchiya, Shunsuke
    Shioya, Satomi
    Okayama, Masahiko
    Sugiyama, Kazuhisa
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (10):
  • [30] Evaluation of the 24-hour intraocular pressure and systemic blood pressure at the same time
    Karadag, R.
    Koyun, E.
    Ozsoy, I
    Caliskan, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (07): : 739 - 745