摘要
Purpose: To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and Methods: Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Safety parameters included best corrected visual acuity, pachymetry, epithelial defects, conjunctival erythema, and corneal topography. Results: Mean age was 61.7 years in group 1 and 65.0 years in group 2. Nineteen healthy subjects and 19 glaucoma patients (95%) completed the 24-hour wearing period. Early discontinuation resulted from pain (n=1) or inappropriate fitting of the sensor due to steep corneal radii (n=1). Mean tolerability was 21.8 in group 1 (range, 7 to 67) and 26.8 in group 2 (range, 0 to 71). Corneal epithelial staining (Modified Oxford scale, grade 0 to 4) changed from 0.4 (group 1) and 1.0 (group 2) at baseline to 1.8 (group 1) and 2.8 (group 2) after monitoring. No statistically significant differences could be detected between both groups. Conclusions: This new pressure-sensitive contact lens is tolerable and safe over a 24-hour wearing period in healthy subjects and glaucoma patients. Both normals and glaucoma patients had a similar safety and tolerability profile.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 50 条
  • [1] Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Tafreshi, Ali
    Weinreb, Robert N.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (12) : 1534 - 1539
  • [2] Personalizing Intraocular Pressure: Target Intraocular Pressure in the Setting of 24-Hour Intraocular Pressure Monitoring
    Sit, Arthur J.
    Pruet, Christopher M.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2016, 5 (01): : 17 - 22
  • [3] Tolerability evaluation of 24-hour blood pressure monitoring
    Lima, NKC
    Santos, LAC
    Brega, AG
    Mion, D
    Nobre, F
    Marin-Neto, JA
    JOURNAL OF HYPERTENSION, 1998, 16 : S270 - S270
  • [4] Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?
    Mansouri, Kaweh
    Weinreb, Robert N.
    Medeiros, Felipe A.
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (03) : 157 - 164
  • [5] 24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression
    Gaboriau, Thibaut
    Dubois, Remi
    Foucque, Boris
    Malet, Florence
    Schweitzer, Cedric
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (03)
  • [6] Influence of Ocular Dimensional Change on 24-Hour Intraocular Pressure Measurement With Contact Lens Sensor
    Tojo, Naoki
    Hayashi, Atsushi
    JOURNAL OF GLAUCOMA, 2019, 28 (09) : 808 - 810
  • [7] Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor
    Liu, John H. K.
    Mansouri, Kaweh
    Weinreb, Robert N.
    PLOS ONE, 2015, 10 (06):
  • [8] 24-hour "intraocular pressure" measurement with sensory contact lens Triggerfish: from euphoria to disillusion
    Faschinger, C.
    Mossboeck, G.
    Strohmaier, C.
    Reitsamer, H. A.
    SPEKTRUM DER AUGENHEILKUNDE, 2011, 25 (04) : 262 - 268
  • [9] The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
    Xu, Sarah C.
    Gauthier, Angela C.
    Liu, Ji
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [10] Role of 24-Hour Intraocular Pressure Monitoring in Glaucoma Management
    Ho, Chun Hing
    Wong, Jasper K. W.
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019