Feasibility and safety of frequency-domain optical coherence tomography for coronary artery evaluation: a single-center study

被引:15
|
作者
Lehtinen, Tuomas [1 ,2 ]
Nammas, Wail [1 ]
Airaksinen, Juhani K. E. [2 ]
Karjalainen, Pasi P. [1 ]
机构
[1] Satakunta Cent Hosp, Ctr Heart, Pori 28500, Finland
[2] Turku Univ Hosp, Dept Med, Turku 20521, Finland
关键词
Optical coherence tomography; Frequency-domain; Safety; Feasibility; ACUTE MYOCARDIAL-INFARCTION; MULTICENTER; LESION;
D O I
10.1007/s10554-013-0196-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We assessed the feasibility and safety of frequency-domain optical coherence tomography (FD-OCT) in a variety of indications. We conducted a retrospective analysis of all FD-OCT examinations performed for research and clinical indications, including stable angina, acute coronary syndromes, diagnostic procedures and percutaneous coronary intervention (PCI), at the Satakunta Central Hospital (Pori, Finland) between August 12th 2009 and February 9th 2011. All pullbacks were screened for image quality. Data on complications and clinical implications of examinations was obtained from patient records. The mean age of the patients was 65.9 +/- A 10.9 years (81.7 % males). A total of 230 examinations were performed on 210 patients; 523 pullbacks were eventually attempted (519 successful). On average, 2.3 +/- A 1.1 pullbacks were performed, and 1.1 +/- A 0.4 vessels were scanned per examination. PCI was performed in 44.3 % of examinations. Radial access was used in 70.3 % of cases. Examination was successful in 202 (87.8 %) examinations. One patient died of heart failure later after PCI for acute myocardial infarction. No cases of major bleeding, myocardial infarction, contrast-induced nephropathy, or pericardial tamponade were encountered. Chest pain occurred in 10.9 % of examinations, minor bleeding in 4.8 %, and myocardial ischemia in 2.6 %. Femoral access was associated with fewer blood and decentration artefacts and a trend towards better image quality when compared to radial access, with no difference in complications. After the first 50 examinations, there appeared to be fewer artefacts in the subsequent examinations. The current study demonstrated that FD-OCT is feasible, with infrequent complications.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 50 条
  • [31] Bivalirudin Versus Unfractionated Heparin for Residual Thrombus Burden: A Frequency-Domain Optical Coherence Tomography Study
    Vergallo, Rocco
    Joye, Russell
    Barlis, Peter
    Jia, Haibo
    Tian, Jinwei
    Soeda, Tsunenari
    Minami, Yoshiyasu
    Hu, Sining
    Dauerman, Harold L.
    Toma, Catalin
    Chan, James
    Lee, Hang
    Biasucci, Luigi Marzio
    Crea, Filippo
    Jang, Ik-Kyung
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (04) : 575 - 582
  • [32] Correlation between frequency-domain optical coherence tomography and fractional flow reserve in angiographically-intermediate coronary lesions
    Burzotta, Francesco
    Nerla, Roberto
    Hill, Jonathan
    Paraggio, Lazzaro
    Leone, Antonio Maria
    Byrne, Jonathan
    Porto, Italo
    Niccoli, Giampaolo
    Aurigemma, Cristina
    Trani, Carlo
    MacCarthy, Philip
    Crea, Filippo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 253 : 55 - 60
  • [33] Three-dimensional imaging of fibrous cap by frequency-domain optical coherence tomography
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Costa, Marco A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 547 - 549
  • [34] Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound
    Yong Liu
    Kunihiro Shimamura
    Takashi Kubo
    Atsuhi Tanaka
    Hironori Kitabata
    Yasushi Ino
    Takashi Tanimoto
    Yasutsugu Shiono
    Makoto Orii
    Takashi Yamano
    Tomoyuki Yamaguchi
    Kumiko Hirata
    Toshio Imanishi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2014, 30 : 271 - 277
  • [35] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Kimura, Masahiro
    Takeda, Teruki
    Tsujino, Yasushi
    Matsumoto, Yuichi
    Yamaji, Masayuki
    Sakaguchi, Tomoko
    Maeda, Keiko
    Mabuchi, Hiroshi
    Murakami, Tomoyuki
    HEART AND VESSELS, 2024, 39 (04) : 310 - 318
  • [36] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Masahiro Kimura
    Teruki Takeda
    Yasushi Tsujino
    Yuichi Matsumoto
    Masayuki Yamaji
    Tomoko Sakaguchi
    Keiko Maeda
    Hiroshi Mabuchi
    Tomoyuki Murakami
    Heart and Vessels, 2024, 39 : 310 - 318
  • [37] Frequency-domain single-shot optical frequency comb tomography using VIPA
    Miyaoka, Takumi
    Shioda, Tatsutoshi
    PHOTONIC INSTRUMENTATION ENGINEERING III, 2016, 9754
  • [38] Quantification of manual thrombus removal in patients with acute coronary syndromes: a study exploiting serial frequency domain-optical coherence tomography
    Imola, Fabrizio
    Mallus, Maria Teresa
    Ramazzotti, Vito
    Manzoli, Alessandro
    Di Vito, Luca
    Occhipinti, Michele
    Cremonesi, Alberto
    Arbustini, Eloisa
    Prati, Francesco
    Albertucci, Mario
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2015, 16 (03) : 204 - 212
  • [39] A new optical coherence tomography method for subfoveal choroidal thickness measurement A single-center observational study
    Kang, Kyung Tae
    Jang, Ji Hye
    Kim, Yu Cheol
    MEDICINE, 2021, 100 (24) : E26355
  • [40] Predictors of Periprocedural (Type IVa) Myocardial Infarction, as Assessed by Frequency-Domain Optical Coherence Tomography
    Porto, Italo
    Di Vito, Luca
    Burzotta, Francesco
    Niccoli, Giampaolo
    Trani, Carlo
    Leone, Antonio M.
    Biasucci, Luigi M.
    Vergallo, Rocco
    Limbruno, Ugo
    Crea, Filippo
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) : 89 - U164