Feasibility and safety of frequency-domain optical coherence tomography for coronary artery evaluation: a single-center study

被引:15
|
作者
Lehtinen, Tuomas [1 ,2 ]
Nammas, Wail [1 ]
Airaksinen, Juhani K. E. [2 ]
Karjalainen, Pasi P. [1 ]
机构
[1] Satakunta Cent Hosp, Ctr Heart, Pori 28500, Finland
[2] Turku Univ Hosp, Dept Med, Turku 20521, Finland
关键词
Optical coherence tomography; Frequency-domain; Safety; Feasibility; ACUTE MYOCARDIAL-INFARCTION; MULTICENTER; LESION;
D O I
10.1007/s10554-013-0196-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We assessed the feasibility and safety of frequency-domain optical coherence tomography (FD-OCT) in a variety of indications. We conducted a retrospective analysis of all FD-OCT examinations performed for research and clinical indications, including stable angina, acute coronary syndromes, diagnostic procedures and percutaneous coronary intervention (PCI), at the Satakunta Central Hospital (Pori, Finland) between August 12th 2009 and February 9th 2011. All pullbacks were screened for image quality. Data on complications and clinical implications of examinations was obtained from patient records. The mean age of the patients was 65.9 +/- A 10.9 years (81.7 % males). A total of 230 examinations were performed on 210 patients; 523 pullbacks were eventually attempted (519 successful). On average, 2.3 +/- A 1.1 pullbacks were performed, and 1.1 +/- A 0.4 vessels were scanned per examination. PCI was performed in 44.3 % of examinations. Radial access was used in 70.3 % of cases. Examination was successful in 202 (87.8 %) examinations. One patient died of heart failure later after PCI for acute myocardial infarction. No cases of major bleeding, myocardial infarction, contrast-induced nephropathy, or pericardial tamponade were encountered. Chest pain occurred in 10.9 % of examinations, minor bleeding in 4.8 %, and myocardial ischemia in 2.6 %. Femoral access was associated with fewer blood and decentration artefacts and a trend towards better image quality when compared to radial access, with no difference in complications. After the first 50 examinations, there appeared to be fewer artefacts in the subsequent examinations. The current study demonstrated that FD-OCT is feasible, with infrequent complications.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 50 条
  • [1] Feasibility and safety of frequency-domain optical coherence tomography for coronary artery evaluation: a single-center study
    Tuomas Lehtinen
    Wail Nammas
    Juhani K. E. Airaksinen
    Pasi P. Karjalainen
    The International Journal of Cardiovascular Imaging, 2013, 29 : 997 - 1005
  • [2] Ventricular Fibrillation During Optical Coherence Tomography/Optical Frequency Domain Imaging - A Large Single-Center Experience -
    Terada, Noriko
    Kuramochi, Tatsuhiko
    Sugiyama, Tomoyo
    Kanaji, Yoshihisa
    Hoshino, Masahiro
    Usui, Eisuke
    Yamaguchi, Masao
    Hada, Masahiro
    Misawa, Toru
    Sumino, Yohei
    Hirano, Hidenori
    Nogami, Kai
    Ueno, Hiroki
    Wakasa, Nobutaka
    Hosokawa, Masahiro
    Murai, Tadashi
    Lee, Tetsumin
    Yonetsu, Taishi
    Kobashi, Kazuhiko
    Kakuta, Tsunekazu
    CIRCULATION JOURNAL, 2020, 84 (02) : 178 - 185
  • [3] Feasibility and Safety of the Novel Vivolight Frequency Domain Optical Coherence Tomography System: A Multicenter Study
    Jin, Qinhua
    Qian, Juying
    Zhou, Yujie
    Jing, Jing
    Wu, Yizhe
    Liu, Yuyang
    Shen, Hua
    Guo, Jun
    Sun, Zhijun
    Wang, Yu
    Chen, Lian
    Chen, Yundai
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06) : E412 - E416
  • [4] Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery
    Dimitris Karnabatidis
    Konstantinos Katsanos
    Ioannis Paraskevopoulos
    Athanasios Diamantopoulos
    Stavros Spiliopoulos
    Dimitris Siablis
    CardioVascular and Interventional Radiology, 2011, 34 : 1172 - 1181
  • [5] Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery
    Karnabatidis, Dimitris
    Katsanos, Konstantinos
    Paraskevopoulos, Ioannis
    Diamantopoulos, Athanasios
    Spiliopoulos, Stavros
    Siablis, Dimitris
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (06) : 1172 - 1181
  • [6] Frequency-Domain Optical Coherence Tomography for Intracranial Atherosclerotic Stenosis: Feasibility, Safety, and Preliminary Experience
    Yang, Bin
    Feng, Yiding
    Ma, Yan
    Wang, Yabing
    Chen, Jian
    Li, Long
    Dong, Jia
    Zhang, Bairu
    Gao, Peng
    Chen, Yanfei
    Dmytriw, Adam A.
    Jiao, Liqun
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [7] Safety and efficacy of frequency-domain optical coherence tomography in evaluating and treating intermediate coronary lesions
    Khurwolah, Mohammad Reeaze
    Meng, Hao-Yu
    Wang, Yong-Sheng
    Wang, Lian-Sheng
    Kong, Xiang-Qing
    WORLD JOURNAL OF CARDIOLOGY, 2018, 10 (11): : 222 - 233
  • [8] Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound
    Liu, Yong
    Shimamura, Kunihiro
    Kubo, Takashi
    Tanaka, Atsuhi
    Kitabata, Hironori
    Ino, Yasushi
    Tanimoto, Takashi
    Shiono, Yasutsugu
    Orii, Makoto
    Yamano, Takashi
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Imanishi, Toshio
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02) : 271 - 277
  • [9] Intravascular Frequency-Domain Optical Coherence Tomography Assessment of Carotid Artery Disease in Symptomatic and Asymptomatic Patients
    不详
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 675 - 684
  • [10] Safety and efficacy of frequency domain optical coherence tomography in pigs
    Li, Xiankai
    Villard, Joseph W.
    Ouyang, Yongjian
    Michalek, Joel E.
    Jabara, Refat
    Sims, Dan
    Kemp, Nate
    Glynn, Tim
    Banas, Christopher
    Bailey, Steven R.
    Feldman, Marc D.
    EUROINTERVENTION, 2011, 7 (04) : 497 - 504