A study on stack configuration of continuous electrodeionization for removal of heavy metal ions from the primary coolant of a nuclear power plant

被引:93
作者
Yeon, KH [1 ]
Song, JH [1 ]
Moon, SH [1 ]
机构
[1] Kwangju Inst Sci & Technol, Cleaner Seperat Lab, Dept Environm Sci & Engn, Gwangju 500712, South Korea
关键词
continuous electrodeionization; primary coolant; ion exchange resin; CEDI; EDI;
D O I
10.1016/j.watres.2004.01.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the production of high-purity water in the primary coolant of a nuclear power plant via the continuous electrodeionization (CEDI) process, using ion exchange resins as ion-conducting media between ion exchange membranes. The effectiveness of this method was examined with respect to the removal of heavy metals. The study was carried out on a laboratory scale with an effective area of 20cm(2). The CEDI system was operated with a layered bed of cation exchange resins, anion exchange resins, and mixed-bed ion exchange resins. The stack configuration was designed to prevent a reaction between metal ions and hydroxide ions. The CEDI operation with the layered bed removed more than 99% of the ions at 30% of the current efficiency. The results showed that, with an inlet 2 conductivity of 40 muS cm(-1), a linear velocity of 4.17 cm s(-1), and an applied current density of 17 mA cm(-2), the CEDI process yielded an outlet conductivity of 0.5 muScm(-1), thereby preventing the precipitation of metal ions. This study therefore successfully demonstrated the feasibility of the CEDI operation for the removal of heavy metals at a very low concentration. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1911 / 1921
页数:11
相关论文
共 14 条
[1]  
BURNS RH, 1958, 2 UN C PEAC US AT EN, P150
[2]  
DAVIS TA, 1977, 270910 NTIS PB SO RE
[3]  
Ganzi G.C., 1988, AIChE Symposium Series, P73
[4]   WATER-PURIFICATION AND RECYCLING USING THE CDI PROCESS [J].
GANZI, GC ;
WOOD, JH ;
GRIFFIN, CS .
ENVIRONMENTAL PROGRESS, 1992, 11 (01) :49-53
[5]  
Glueckauf E., 1959, Br. Chem. Eng., V4, P646
[6]   Use of continuous electrodeionization to reduce ammonia concentration in steam generators blow-down of PWR nuclear power plants [J].
Goffin, C ;
Calay, JC .
DESALINATION, 2000, 132 (1-3) :249-253
[7]  
Guiffrida, 1987, ULTRAPURE WATER, V4, P43
[8]  
HERNON BP, 1994, ULTRAPURE WATER JUL, P33
[9]  
Kang D. W., 1998, J KOREA SOLID WASTES, V15, P24
[10]  
SEVERA J, 1991, HDB RADIOACTIVE CONT, V21, P117