Progressive Collapse Analysis of a Typical Super-Tall Reinforced Concrete Frame-Core Tube Building Exposed to Extreme Fires

被引:26
作者
Lu, Xinzheng [1 ]
Li, Yi [2 ]
Guan, Hong [3 ]
Ying, Mingjian [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Minist Educ, Key Lab Civil Engn Safety & Durabil, Beijing 100084, Peoples R China
[2] Beijing Univ Technol, Beijing Collaborat Innovat Ctr Metropolitan Trans, Minist Educ, Key Lab Urban Secur & Disaster Engn, Beijing 100124, Peoples R China
[3] Griffith Univ Gold Coast Campus, Griffith Sch Engn, Southport, Qld 4222, Australia
基金
澳大利亚研究理事会; 中国国家自然科学基金;
关键词
Extreme fire; Super-tall building; Frame-core tube structure; Progressive collapse; Collapse mode; STEEL STRUCTURES; ASSESSING PERFORMANCE; BEHAVIOR; METHODOLOGY; RESISTANCE; COLUMNS;
D O I
10.1007/s10694-016-0566-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A number of disastrous incidents have indicated that extreme fires can act as a trigger event to initiate the progressive collapse of reinforced concrete (RC) structures. Hence, research on progressive collapse risks of RC structures under extreme fires is most important. However, limited studies have been undertaken in the fire-induced progressive collapse of tall and super-tall RC buildings. Hence, a high-performance finite element model was developed for this study to simulate the mechanical behavior of RC members in fire-induced progressive collapse. Fiber beam and multi-layer shell elements were used, in conjunction with appropriate material constitutive laws and elemental failure criteria under high temperature conditions. Extreme fire scenarios were also considered, based on the actual fire-induced progressive collapse events of the WTC towers and the Windsor Tower. The simulation results indicated that a progressive collapse of a super-tall building was triggered by the flexural failure of the peripheral columns, approximately 7 h after being exposed to fire. The bending deformations of the peripheral columns increased significantly, due to the outward thermal expansion of the upper floors and the inward contraction of the lower floors, a result of the fire-induced damage. The results also revealed that, when multiple stories are subjected to fire, the internal forces in the components are redistributed in the horizontal and vertical directions by way of the Vierendeel truss mechanism, leading to a maximum increase (of approximately 100%) of the axial forces in the columns. The present work identified the mechanisms of the fire-induced progressive collapse of a typical RC super-tall building, and provided an effective analysis framework for further research on the fire safety of tall and super-tall RC buildings.
引用
收藏
页码:107 / 133
页数:27
相关论文
共 44 条
[1]  
American Society of Civil Engineers Structural Engineering Institute (ASCE/SEI), 2010, MIN DELOADBUILD
[2]  
[Anonymous], 2011, CASE STUDIES SEISMIC
[3]  
[Anonymous], JGJ32010 MIN HOUS UR
[4]  
[Anonymous], 2008, E119 ASTM
[5]   Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire [J].
Bisby, LA ;
Green, MF ;
Kodur, VKR .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) :15-24
[6]   Non-linear fire-resistance analysis of reinforced concrete beams [J].
Bratina, S ;
Planinc, I ;
Saje, M ;
Turk, G .
STRUCTURAL ENGINEERING AND MECHANICS, 2003, 16 (06) :695-712
[7]  
China Association for Engineering Construction Standardization, 2014, 392 CECS
[8]  
*COMM EUR COMM, 2004, EN199212 COMM EUR CO
[9]  
Fletcher I.A., 2009, TALL CONCRETE BUILDI
[10]   Recent Lessons Learned in Structural Fire Engineering for Composite Steel Structures [J].
Flint, G. ;
Lamont, S. ;
Lane, B. ;
Sarrazin, H. ;
Lim, L. ;
Rini, Darlene ;
Roben, C. .
FIRE TECHNOLOGY, 2013, 49 (03) :767-792