Effect of an on-body ergonomic aid on oxygen consumption during a repetitive lifting task

被引:57
作者
Whitfield, Brett H. [1 ]
Costigan, Patrick A. [1 ]
Stevenson, Joan M. [1 ]
Smallman, Catherine L. [1 ]
机构
[1] Queens Univ, Sch Kinesiol & Hlth Studies, Kingston, ON K7L 3N6, Canada
关键词
PLAD; Oxygen consumption; Physiological demand; EMG; AUGMENTATION DEVICE PLAD; ASSIST DEVICE; BACK-PAIN; FATIGUE; SQUAT; STOOP; PREVALENCE; AMPLITUDE; INDUSTRY; MOMENTS;
D O I
10.1016/j.ergon.2013.10.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of this study was to determine if an on-body personal lift assistive device (PLAD)(1) affected oxygen consumption during a continuous lifting task and to investigate if any effect could be explained by differences in muscle activity or lifting technique. The PLAD, worn like a back-pack, contains a spring-cable mechanism that assists the back musculature during lifting, lowering, and forward bending tasks. Males (n = 15) lifted and lowered a box loaded to 10% of their maximum back strength at 6 times/minute for 15-minutes using a free-style technique under two conditions: wearing and not wearing the PLAD. Oxygen consumption was collected continuously for the first condition; then the participants rested until their heart rates returned to resting levels before repeating the protocol for the second condition. Knee flexion was monitored using Liberty sensors at the hip, knee, and ankle. EMG of the thoracic and lumbar erector spinae (TES, LES), biceps femoris, rectus femoris and gluteus maximus were gathered using a Bortec AMT-8 channel system. VO2 measures were averaged across the duration (15 min) for each condition. Results showed no differences between oxygen consumption during the PLAD and no PLAD conditions. When wearing the PLAD, the TES demonstrated an 8.4% EMG reduction when lowering the box while the biceps femoris showed a 14% reduction while lifting the box. Knee angles, used as a proxy for stoop or squat lifts, were highly variable for both conditions. In conclusion, the PLAD had no effect on oxygen consumption and, therefore, neither workers nor employers should increase the tasks demands when wearing this ergonomic aid. Relevance to industry: While the PLAD reduced musculoskeletal effort required by back musculature, loads or rates of lifting should not be increased since there is no change in the overall physical demand of the task. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 26 条
[1]   The effect of on-body lift assistive device on the lumbar 3D dynamic moments and EMG during asymmetric freestyle lifting [J].
Abdoli-E, Mohammad ;
Stevenson, Joan M. .
CLINICAL BIOMECHANICS, 2008, 23 (03) :372-380
[2]   An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasks [J].
Abdoli-E, Mohammad ;
Agnew, Michael J. ;
Stevenson, Joan M. .
CLINICAL BIOMECHANICS, 2006, 21 (05) :456-465
[3]   Mathematical and empirical proof of principle for an on-body personal lift augmentation device (PLAD) [J].
Abdoli-Eramaki, Mohammad ;
Stevenson, Joan M. ;
Reid, Susan A. ;
Bryant, Timothy J. .
JOURNAL OF BIOMECHANICS, 2007, 40 (08) :1694-1700
[4]   The effect of perspiration on the sEMG amplitude and power spectrum [J].
Abdoli-Eramaki, Mohammad ;
Damecour, Caroline ;
Christenson, John ;
Stevenson, Joan .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2012, 22 (06) :908-913
[5]  
Boos N., 2008, SPINAL DISORDERS FUN, P156, DOI 10.1007/978-3-540-69091-7
[6]   Changes in lifting dynamics after localized arm fatigue [J].
Chen, YL .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2000, 25 (06) :611-619
[7]   The Rising Prevalence of Chronic Low Back Pain [J].
Freburger, Janet K. ;
Holmes, George M. ;
Agans, Robert P. ;
Jackman, Anne M. ;
Darter, Jane D. ;
Wallace, Andrea S. ;
Castel, Liana D. ;
Kalsbeek, William D. ;
Carey, Timothy S. .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (03) :251-258
[8]   PLAD (personal lift assistive device) stiffness affects the lumbar flexion/extension moment and the posterior chain EMG during symmetrical lifting tasks [J].
Frost, David M. ;
Abdoli-E, Mohammad ;
Stevenson, Joan M. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (06) :E403-E412
[9]   MECHANICAL AND ELECTROMYOGRAPHIC COMPARISON BETWEEN THE STOOP AND THE SQUAT LIFTING METHODS [J].
GIAT, Y ;
PIKE, N .
JOURNAL OF SAFETY RESEARCH, 1992, 23 (02) :95-105
[10]   Testing the efficacy of an ergonomic lifting aid at diminishing muscular fatigue in women over a prolonged period of lifting [J].
Godwin, Alison A. ;
Stevenson, Joan M. ;
Agnew, Michael J. ;
Twiddy, Alexis L. ;
Abdoli-Eramaki, Mohammad ;
Lotz, Christy A. .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2009, 39 (01) :121-126